Accuracy and reproducibility of turbidity measurements in urban waste water

被引:4
|
作者
Ruban, G.
Bertrand-Krajewski, J. -L.
Chebbo, G.
Gromaire, M. C.
Joannis, C.
机构
[1] Lab Cent Ponts & Chaussees, F-44341 Bouguenais, France
[2] Inst Natl Sci Appl, URGC, F-69621 Villeurbanne, France
[3] CEREVE, ENPC, F-77455 Marne La Vallee 2, France
[4] GEMCEA, F-54500 Vandoeuvre Les Nancy, France
来源
HOUILLE BLANCHE-REVUE INTERNATIONALE DE L EAU | 2006年 / 04期
关键词
D O I
10.1051/lhb:200604022
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Measuring the turbidity of urban sewage is interesting because in raw waste water, pollutants are mainly particulates and/or bound to particulates. Moreover it is a real time and continuous measurement. This paper deals with knowledge elements and methods for the determination of the components of the uncertainty on turbidity measurement on water samples (principle of measurement, calibration, drift,...). These methods contribute to the use of this measurement technique by operators of urban drainage systems. They were applied for comparing experimental results obtained with various devices and various calibration and sampling strategies. The level of overall short term accuracy reached for turbidity measurement in urban waste water is satisfactory, provided that the non-linearity of some devices to corrected if needed.
引用
收藏
页码:129 / 135
页数:7
相关论文
共 50 条
  • [31] Accuracy or reproducibility?
    Robinson, P
    NUCLEAR MEDICINE COMMUNICATIONS, 1998, 19 (03) : 293 - 293
  • [32] Accuracy and Reproducibility of Linear and Angular Measurements in Virtual Reality: a Validation Study
    Anik, Asif Ahmed
    Xavier, Brian A.
    Hansmann, Jan
    Ansong, Emmanuel
    Chen, Jinsong
    Zhao, Linping
    Michals, Edward
    JOURNAL OF DIGITAL IMAGING, 2020, 33 (01) : 111 - 120
  • [33] FACTORS INVOLVED IN THE ACCURACY AND REPRODUCIBILITY OF DEPTH MEASUREMENTS ON NUCLEAR RESEARCH EMULSIONS
    MCALISTER, JM
    KEAM, DW
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION A, 1951, 64 (373): : 91 - 92
  • [34] Accuracy and reproducibility of X-ray texture measurements on thin films
    Vaudin, MD
    Fox, GR
    Kowach, GR
    MAGNETIC AND ELECTRONIC FILMS-MICROSTRUCTURE, TEXTURE AND APPLICATION TO DATA STORAGE, 2002, 721 : 17 - 22
  • [35] Accuracy, reproducibility, and time efficiency of dental measurements using different technologies
    Gruenheid, Thorsten
    Patel, Nishant
    De Felippe, Nanci L.
    Wey, Andrew
    Gaillard, Philippe R.
    Larsonf, Brent E.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 145 (02) : 157 - 164
  • [36] Accuracy and reproducibility of automated, standardized coronary transluminal attenuation gradient measurements
    Yiannis S. Chatzizisis
    Elizabeth George
    Tianrun Cai
    Urvi P. Fulwadhva
    Kanako K. Kumamaru
    Kurt Schultz
    Yasuko Fujisawa
    Carlos Rassi
    Michael Steigner
    Richard T. Mather
    Ron Blankstein
    Frank J. Rybicki
    Dimitrios Mitsouras
    The International Journal of Cardiovascular Imaging, 2014, 30 : 1181 - 1189
  • [37] Accuracy and Reproducibility of Plethysmographic Thoracic Gas Volume Measurements in Healthy Subjects
    Siddharthan, T.
    Dalzell, M.
    Grealis, K.
    Gonzalez, E.
    Wanner, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [38] Accuracy and Reproducibility of Linear and Angular Measurements in Virtual Reality: a Validation Study
    Asif Ahmed Anik
    Brian A. Xavier
    Jan Hansmann
    Emmanuel Ansong
    Jinsong Chen
    Linping Zhao
    Edward Michals
    Journal of Digital Imaging, 2020, 33 : 111 - 120
  • [40] In-vitro assessment of reproducibility and accuracy of probing depth measurements.
    Patel, K
    Griffiths, GS
    Gillam, D
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 992 - 992