Accuracy and reproducibility of turbidity measurements in urban waste water

被引:4
|
作者
Ruban, G.
Bertrand-Krajewski, J. -L.
Chebbo, G.
Gromaire, M. C.
Joannis, C.
机构
[1] Lab Cent Ponts & Chaussees, F-44341 Bouguenais, France
[2] Inst Natl Sci Appl, URGC, F-69621 Villeurbanne, France
[3] CEREVE, ENPC, F-77455 Marne La Vallee 2, France
[4] GEMCEA, F-54500 Vandoeuvre Les Nancy, France
关键词
D O I
10.1051/lhb:200604022
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Measuring the turbidity of urban sewage is interesting because in raw waste water, pollutants are mainly particulates and/or bound to particulates. Moreover it is a real time and continuous measurement. This paper deals with knowledge elements and methods for the determination of the components of the uncertainty on turbidity measurement on water samples (principle of measurement, calibration, drift,...). These methods contribute to the use of this measurement technique by operators of urban drainage systems. They were applied for comparing experimental results obtained with various devices and various calibration and sampling strategies. The level of overall short term accuracy reached for turbidity measurement in urban waste water is satisfactory, provided that the non-linearity of some devices to corrected if needed.
引用
收藏
页码:129 / 135
页数:7
相关论文
共 50 条
  • [21] CYCLOSPORINE ASSAY TECHNIQUES - ACCURACY AND REPRODUCIBILITY VARIABLES IMPACTING ON MEASUREMENTS
    HOLT, DW
    JOHNSTON, A
    NUCLEAR MEDICINE AND BIOLOGY, 1990, 17 (07) : 733 - 736
  • [22] Turbidity measurements
    不详
    CHIMICA OGGI-CHEMISTRY TODAY, 1998, 16 (10) : 97 - 97
  • [23] WATER POLLUTION Urban waste
    Armstrong, Anna
    NATURE GEOSCIENCE, 2009, 2 (11) : 748 - 748
  • [24] Study on the Parameters Influencing the Accuracy and Reproducibility of Dynamic Pressure Measurements at the Surface of a Rigid Body During Water Impact
    Van Nuffel, D.
    Vepa, K. S.
    De Baere, I.
    Degrieck, J.
    De Rouck, J.
    Van Paepegem, W.
    EXPERIMENTAL MECHANICS, 2013, 53 (02) : 131 - 144
  • [25] Study on the Parameters Influencing the Accuracy and Reproducibility of Dynamic Pressure Measurements at the Surface of a Rigid Body During Water Impact
    D. Van Nuffel
    K. S. Vepa
    I. De Baere
    J. Degrieck
    J. De Rouck
    W. Van Paepegem
    Experimental Mechanics, 2013, 53 : 131 - 144
  • [26] Study on the parameters influencing the accuracy and reproducibility of dynamic pressure measurements at the surface of a rigid body during water impact
    Van Nuffel, D. (diederik.vannuffel@ugent.be), 1600, Society for Experimental Mechanics Inc. (53):
  • [27] Reproducibility of waste water BOD determination by the dilution method
    Kostina, L.M.
    Pateyuk, V.M.
    Golovatyi, E.I.
    Kharitonov, G.P.
    Soviet journal of water chemistry and technology, 1988, 10 (02): : 92 - 94
  • [28] Validation of a new measuring system for water turbidity field measurements
    Teemu Näykki
    Sampsa Koponen
    Tero Väisänen
    Timo Pyhälahti
    Timo Toivanen
    Ivo Leito
    Accreditation and Quality Assurance, 2014, 19 : 175 - 183
  • [29] Validation of a new measuring system for water turbidity field measurements
    Naykki, Teemu
    Koponen, Sampsa
    Vaisanen, Tero
    Pyhalahti, Timo
    Toivanen, Timo
    Leito, Ivo
    ACCREDITATION AND QUALITY ASSURANCE, 2014, 19 (03) : 175 - 183
  • [30] Application of JERS-1 data for water turbidity measurements
    Tronin, AA
    EARTH OBSERVATION AND REMOTE SENSING, 1995, 13 (01): : 61 - 70