Accuracy and reproducibility of turbidity measurements in urban waste water

被引:4
|
作者
Ruban, G.
Bertrand-Krajewski, J. -L.
Chebbo, G.
Gromaire, M. C.
Joannis, C.
机构
[1] Lab Cent Ponts & Chaussees, F-44341 Bouguenais, France
[2] Inst Natl Sci Appl, URGC, F-69621 Villeurbanne, France
[3] CEREVE, ENPC, F-77455 Marne La Vallee 2, France
[4] GEMCEA, F-54500 Vandoeuvre Les Nancy, France
关键词
D O I
10.1051/lhb:200604022
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Measuring the turbidity of urban sewage is interesting because in raw waste water, pollutants are mainly particulates and/or bound to particulates. Moreover it is a real time and continuous measurement. This paper deals with knowledge elements and methods for the determination of the components of the uncertainty on turbidity measurement on water samples (principle of measurement, calibration, drift,...). These methods contribute to the use of this measurement technique by operators of urban drainage systems. They were applied for comparing experimental results obtained with various devices and various calibration and sampling strategies. The level of overall short term accuracy reached for turbidity measurement in urban waste water is satisfactory, provided that the non-linearity of some devices to corrected if needed.
引用
收藏
页码:129 / 135
页数:7
相关论文
共 50 条
  • [1] Reproducibility and uncertainty of wastewater turbidity measurements
    Joannis, C.
    Ruban, G.
    Gromaire, M. -C.
    Bertrand-Krajewski, J. -L.
    Chebbo, G.
    WATER SCIENCE AND TECHNOLOGY, 2008, 57 (10) : 1667 - 1673
  • [2] REGIONAL LUNG WATER MEASUREMENTS WITH PET - ACCURACY, REPRODUCIBILITY, AND LINEARITY
    VELAZQUEZ, M
    HALLER, J
    AMUNDSEN, T
    SCHUSTER, DP
    JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (04) : 719 - 725
  • [3] TURBIDITY AND PARTICLES IN WATER AND WASTE
    MURREN, C
    CONTROL AND INSTRUMENTATION, 1993, 25 (06): : 35 - 36
  • [4] Accuracy and reproducibility of syringe measurements
    Lee, SN
    Wong, AH
    Mayer, A
    Walker, SE
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 1996, 53 (10) : 1166 - 1169
  • [5] Reproducibility and accuracy of noble gas measurements on water samples in the microlitre range
    Sander, Tim
    Marx, Thomas
    Engel, Juergen
    Aeschbach-Hertig, Werner
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (01) : 42 - 48
  • [6] RADIOMETRY OF WATER TURBIDITY MEASUREMENTS
    MCCLUNEY, WR
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1975, 47 (02): : 252 - 266
  • [7] Snapshots Analyses for Turbidity Measurements in Water
    Antonio Cesar Godoy
    Alberto Yoshihiro Nakano
    David Antônio Brum Siepmann
    Ricardo Schneider
    Felipe Walter Dafico Pfrimer
    Oscar Oliveira Santos
    Water, Air, & Soil Pollution, 2018, 229
  • [8] Snapshots Analyses for Turbidity Measurements in Water
    Godoy, Antonio Cesar
    Nakano, Alberto Yoshihiro
    Brum Siepmann, David Antonio
    Schneider, Ricardo
    Dafico Pfrimer, Felipe Walter
    Santos, Oscar Oliveira
    WATER AIR AND SOIL POLLUTION, 2018, 229 (12):
  • [9] ACCURACY AND PRECISION OF SMARTPHONES IN MEASUREMENTS OF ILLUMINANCE AND LIQUID TURBIDITY
    Tongjan, N.
    Sirisathitkul, C.
    REVISTA CUBANA DE FISICA, 2020, 37 (02): : 131 - 134
  • [10] Accuracy and reproducibility of wavefront measurements with the aberrometer.
    Kaemmerer, M
    Mierdel, P
    Mrochen, M
    Seiler, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S679 - S679