A comparison between in vivo radiographic working length determination and measurement after extraction

被引:69
|
作者
Williams, Clayton B. [1 ]
Joyce, Anthony P. [1 ]
Roberts, Steven [1 ]
机构
[1] USA DENTAC, DDS, Tingay Dent Clin, Endodont Residency Program, Ft Gordon, GA 30905 USA
关键词
electronic apex locator; major foramen; minor diameter; radiographic working length; working length; working length determination;
D O I
10.1016/j.joen.2005.10.044
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to compare the difference between the in vivo working length established by viewing a periapical radiograph and the in vitro measurement from the file tip to the apical foramen of the extracted tooth. Twenty-six canals from teeth that had been treatment planned for extraction were accessed under rubber dam isolation. The coronal portion of each canal was flared using Gates Glidden drills, and a K-type file was inserted down the canal until an electronic apex locator indicated that the file had reached the apex. A size 20 K-type file was locked into place with glass ionomer cement at this position. A radiograph was exposed and the tooth was extracted. Each tooth was viewed using a videomicroscope at 30 X original magnification, and the distance from the file tip to the most coronal aspect of the major foramen was measured. Six examiners viewed each radiograph and assessed the working length of each canal. chi(2) analysis of the data revealed a significant difference (p < 0.01) between the estimation of working lengths and the microscopic measurements. The examiners overestimated the distance between the file tip and the apical foramen of the tooth when the file was placed short, and underestimated the distance when the file was placed long. In conclusion, when the file is short it is actually closer to the apical foramen than it appears radiographically; when it is long it is actually longer than it appears radiographically.
引用
收藏
页码:624 / 627
页数:4
相关论文
共 50 条
  • [41] Determination of Vertical Interproximal Bone Loss Topography: Correlation Between Indirect Digital Radiographic Measurement and Clinical Measurement
    Esmaeli, Farzad
    Shirmohammadi, Adileh
    Faramarzie, Masoumeh
    Abolfazli, Nader
    Rasouli, Hossein
    Fallahi, Saied
    IRANIAN JOURNAL OF RADIOLOGY, 2012, 9 (02) : 83 - 87
  • [42] Influence of embedding media on the accuracy of working length determination by means of apex locator: an ex vivo study
    Wolf, Thomas Gerhard
    Krauss-Mironjuk, Anna
    Wierichs, Richard Johannes
    Briseno-Marroquin, Benjamin
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [43] DETERMINATION OF COMPOSITION AND MIXING LENGTH BY COMPARISON BETWEEN STELLAR MODELS AND OBSERVATIONS
    IBEN, I
    ASTRONOMICAL JOURNAL, 1962, 67 (05): : 274 - &
  • [44] Influence of embedding media on the accuracy of working length determination by means of apex locator: an ex vivo study
    Thomas Gerhard Wolf
    Anna Krauß-Mironjuk
    Richard Johannes Wierichs
    Benjamín Briseño-Marroquín
    Scientific Reports, 11
  • [45] Assessment of endodontically treated teeth by using different radiographic methods: an ex vivo comparison between CBCT and other radiographic techniques
    Demiralp, Kemal Ozgur
    Kamburoglu, Kivanc
    Gungor, Kahraman
    Yuksel, Selcen
    Deiniralp, Gokcen
    Ucok, Ozlem
    IMAGING SCIENCE IN DENTISTRY, 2012, 42 (03) : 129 - 137
  • [46] Comparison between in vivo measurement of the Montenegro skin test and paper recording
    Fagundes, Aline
    Antonio, Liliane
    Schubach, Armando
    Marzochi, Keyla B. F.
    INTERNATIONAL JOURNAL OF DERMATOLOGY, 2012, 51 (05) : 618 - 619
  • [47] A Radiographic Comparison of the Root Length and Area After Class II Treatment with Two Different Functional Appliances
    Seker, Elif Dilara
    Yagci, Ahmet
    Kurt Demirsoy, Kevser
    Yuzuak, Ela Nur
    BEZMIALEM SCIENCE, 2020, 8 (04): : 321 - 329
  • [48] COMPARISON BETWEEN SFE AND SOXHLET EXTRACTION IN THE DETERMINATION OF PCB IN SOIL SAMPLES
    MORSELLI, L
    SABBIONI, M
    ZAPPOLI, S
    QUATTRONI, G
    FRESENIUS ENVIRONMENTAL BULLETIN, 1995, 4 (08): : 463 - 468
  • [49] A comparison between direct determination of in vivo dissolution and the deconvolution technique in humans
    Bonlokke, L
    Hovgaard, L
    Kristensen, HG
    Knutson, L
    Lindahl, A
    Lennernäs, H
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 1999, 8 (01) : 19 - 27
  • [50] MEASUREMENT OF CERVICAL LENGTH IN PREGNANCY - COMPARISON BETWEEN VAGINAL ULTRASONOGRAPHY AND DIGITAL EXAMINATION
    SONEK, JD
    IAMS, JD
    BLUMENFELD, M
    JOHNSON, F
    LANDON, M
    GABBE, S
    OBSTETRICS AND GYNECOLOGY, 1990, 76 (02): : 172 - 175