A comparison between in vivo radiographic working length determination and measurement after extraction

被引:69
|
作者
Williams, Clayton B. [1 ]
Joyce, Anthony P. [1 ]
Roberts, Steven [1 ]
机构
[1] USA DENTAC, DDS, Tingay Dent Clin, Endodont Residency Program, Ft Gordon, GA 30905 USA
关键词
electronic apex locator; major foramen; minor diameter; radiographic working length; working length; working length determination;
D O I
10.1016/j.joen.2005.10.044
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to compare the difference between the in vivo working length established by viewing a periapical radiograph and the in vitro measurement from the file tip to the apical foramen of the extracted tooth. Twenty-six canals from teeth that had been treatment planned for extraction were accessed under rubber dam isolation. The coronal portion of each canal was flared using Gates Glidden drills, and a K-type file was inserted down the canal until an electronic apex locator indicated that the file had reached the apex. A size 20 K-type file was locked into place with glass ionomer cement at this position. A radiograph was exposed and the tooth was extracted. Each tooth was viewed using a videomicroscope at 30 X original magnification, and the distance from the file tip to the most coronal aspect of the major foramen was measured. Six examiners viewed each radiograph and assessed the working length of each canal. chi(2) analysis of the data revealed a significant difference (p < 0.01) between the estimation of working lengths and the microscopic measurements. The examiners overestimated the distance between the file tip and the apical foramen of the tooth when the file was placed short, and underestimated the distance when the file was placed long. In conclusion, when the file is short it is actually closer to the apical foramen than it appears radiographically; when it is long it is actually longer than it appears radiographically.
引用
收藏
页码:624 / 627
页数:4
相关论文
共 50 条
  • [21] Comparison between fibre length measurement methods
    Bentley, R.G.
    Scudamore, P.
    Jack, J.S.
    Pulp and Paper Canada, 1994, 95 (04): : 41 - 45
  • [22] Endodontic working length assessment - Comparison of storage phosphor digital imaging and radiographic film
    Cederberg, RA
    Tidwell, E
    Frederiksen, NL
    Benson, BW
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 85 (03): : 325 - 328
  • [23] A COMPARISON BETWEEN FIBER LENGTH MEASUREMENT METHODS
    BENTLEY, RG
    SCUDAMORE, P
    JACK, JS
    PULP & PAPER-CANADA, 1994, 95 (04) : 41 - 45
  • [24] Comparison of Tentative Radiographic Working Length with and without grid Versus Electronic Apex Locator
    Rambabu, Tanikonda
    Srikanth, Visinigiri
    Sajjan, Girija S.
    Ganguru, Sirisha
    Gayatri, Chava
    Roja, K.
    CONTEMPORARY CLINICAL DENTISTRY, 2018, 9 (01) : 88 - 91
  • [25] Ex vivo investigation on the postoperative integrity of the apical constriction after the sole use of electronic working length determination
    Wolgin, Michael
    Grundmann, Markus J.
    Tchorz, Joerg P.
    Frank, Wilhelm
    Kielbassa, Andrej M.
    JOURNAL OF DENTISTRY, 2017, 64 : 52 - 57
  • [26] Ex vivo comparison of radiographic and electronic root canal length measurements in primary molars
    Topaloglu-Ak, A.
    Yetkiner, A. Aykut
    Baksi, B. Guniz
    Eronat, C.
    EUROPEAN JOURNAL OF PAEDIATRIC DENTISTRY, 2015, 16 (02) : 149 - 153
  • [27] Comparison of working length determination with radiographs and four electronic apex locators
    Vieyra, J. P.
    Acosta, J.
    INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (06) : 510 - 518
  • [28] Comparison of working length determination with radiographs and two electronic apex locators
    Vieyra, J. P.
    Acosta, J.
    Mondaca, J. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (01) : 16 - 20
  • [29] Accuracy of working length determination with root ZX apex locator and radiography: An in vivo and ex vivo study
    Zand, Vahid
    Mokhtari, Hadi
    Lotfi, Mehrdad
    Reyhani, Mohammad Forough
    Sohrabi, Aydin
    Tehranchi, Pardis
    Zenouzi, Hamid Reza Mokhtari
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (36): : 7088 - 7091
  • [30] Electronic determination of root canal working length in primary molar teeth: an in vivo and ex vivo study
    Beltrame, A. P. C. A.
    Triches, T. C.
    Sartori, N.
    Bolan, M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (05) : 402 - 406