Study on field demonstration of high-sensitivity SF6 leakage detection method for gas insulated switchgear

被引:1
|
作者
Tatemi, Masaru [1 ]
Inami, Hisao [1 ]
Rokunohe, Toshiaki [1 ]
Hirose, Makoto [2 ]
机构
[1] Hitachi Ltd, Res & Dev Grp, 7-2-1 Omika cho, Hitachi, Ibaraki 3191221, Japan
[2] Hitachi Ltd, T&D Engn & Prod Div, Hitachi, Ibaraki, Japan
关键词
diagnosis; gas pressure; gas‐ insulated switchgear; slow leakage; sulfur hexafluoride;
D O I
10.1002/eej.23295
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
SF6 gas is widely used in power equipment such as gas insulated switchgear or gas circuit breaker. However, its global warming potential is 23,500 times higher than that of CO2. In consideration of environmental protection, detection of SF6 gas leakage with high sensitivity is necessary. The authors proposed an algorithm to accurately estimate the average gas temperature from the tank surface temperature for establishing a high-sensitive SF6 slow leak detection technology. Since the gas temperature depends on the temperature of the conductor, the algorithm was characterized by estimating the gas temperature from the tank surface temperature and the load current. The relationship among the tank surface temperature, the gas temperature, and the current was preliminarily investigated by the use of the thermal fluid analysis and stored in the database. By use of this method, the fluctuation of the converted pressure in the basic examination test was suppressed to 20% as compared with that without considering the current. In addition, database was also created from the machine learning of field test result in substitution. In the field test, it was confirmed that the detection time of 0.5%/year slow leak could be detected in about 8 months by considering the load current.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [41] Comparison of CF3CHCl2 Gas with SF6 Gas as an Alternative Substitute for Gas Insulated Switchgear Equipment
    Juliandhy, Tedy
    Haryonol, T.
    Suharyanto
    Perdana, Indra
    2017 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND POWER SYSTEMS (ICHVEPS), 2017, : 198 - 203
  • [42] Comparisons and Analysis of the Equipments and Methods for SF6 Gas Leakage Detection
    Yi, Xiaochun
    Jiang, Bin
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 204 - 207
  • [43] New optical detection technology of SF6 gas leakage in GIS
    Wu, Bian-Tao
    Xiao, Deng-Ming
    Yin, Yi
    Gaoya Dianqi/High Voltage Apparatus, 2005, 41 (02): : 116 - 118
  • [44] Evaluation of SF6 Leakage from Gas Insulated Equipment on Electricity Networks in Great Britain
    Widger, Phillip
    Haddad, Abderrahmane
    ENERGIES, 2018, 11 (08):
  • [45] An Effective Low-Contrast SF6 Gas Leakage Detection Method for Infrared Imaging
    Lu, Quan
    Li, Qin
    Hu, Likun
    Huang, Lifeng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [46] A High Precision Cost-effective Ultrasonic Sensor for Detection of Gas Leakage in Gas Insulated Switchgear
    Das, Soumya Debashis
    Akram, Kazi Jabed
    Biswal, Gyan Ranjan
    Islam, Tarikul
    2021 INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND FUTURE ELECTRIC TRANSPORTATION (SEFET), 2021,
  • [47] 420 KV SF6 GAS-INSULATED SWITCHGEAR INSTALLATION FOR THE PUMPED-STORAGE PLANT DRAKENSBERG
    FRANTZ, RAJ
    LOHMANN, V
    SPENDAL, E
    BROWN BOVERI REVIEW, 1981, 68 (3-4): : 113 - 119
  • [48] Triangle Fault Diagnosis Method for SF6 Gas-Insulated Equipment
    Wu, Siying
    Zeng, Fuping
    Tang, Ju
    Yao, Qiang
    Miao, Yulong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (04) : 1470 - 1477
  • [49] HIGH-VOLTAGE SF6-INSULATED SWITCHGEAR - GAS MONITORING, MAINTENANCE AND SERVICING
    MEIER, A
    STOLARZ, W
    OTTISCHNIG, R
    BROWN BOVERI REVIEW, 1972, 59 (04): : 163 - +
  • [50] Analysis for Partial Discharges Behavior in SF6 Gas Filled Void in Gas Insulated Switchgear under Oscillating Switching Impulses
    Zhang C.
    Ren M.
    Zhou J.
    Dong M.
    Que B.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 (14): : 3074 - 3083