Sensitivity of the COBAS AmpliScreen™ HIV-1 Test v1.5 for HIV-1 detection

被引:0
|
作者
Gomez, Lucia P. [1 ,2 ]
Balangero, Marcos C. [1 ,2 ]
Castro, Gonzalo [1 ,3 ]
Kademian, Silvia [3 ]
Mangeaud, Arnaldo [4 ]
Barbas, Maria G. [3 ]
Cudola, Analia [3 ]
de Leon, Juan F. [2 ,3 ]
Carrizo, Horacio [2 ]
Gallego, Sandra V. [1 ,2 ,3 ]
机构
[1] Univ Nacl Cordoba UNC, Fac Ciencias Med, Inst Virol Dr JM Vanella, Lab Virus Linfotrop Humanos Retrovirus HIV & HTLV, Cordoba, Argentina
[2] Fdn Banco Cent Sangre, Lab Biol Mol, Cordoba, Argentina
[3] Minist Salud, Lab Cent Prov Cordoba, Cordoba, Argentina
[4] UNC, Catedra Estadist & Biometria, Fac Ciencias Exactas Fis & Nat, Cordoba, Argentina
来源
REVISTA ARGENTINA DE MICROBIOLOGIA | 2014年 / 46卷 / 03期
关键词
NAT; HIV-1; COBAS AmpliScreen; HUMAN-IMMUNODEFICIENCY-VIRUS; BLOOD-DONATIONS; AMPLIFICATION; ARGENTINA; MULTICENTER; INFECTIONS; DONOR; ASSAY; RNA; DNA;
D O I
10.1016/S0325-7541(14)70072-0
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The introduction of nucleic acid amplification techniques (NAT) in blood banks was intended to reduce the residual risk of transfusion-transmitted infections. Co-circulation of a great diversity of HIV-1 variants in Argentina portrays the need to assess the sensitivity of serological and molecular assays available for their detection. In this study, we evaluated the sensitivity of the COBAS AmpliScreen (TM) HIV-1 Test, version 1.5 (Roche) for the detection of HIV-1 RNA in plasma samples of infected individuals from Argentina. The results of this study reveal that this technique has high sensitivity for the detection of HIV-1 RNA under assay conditions: using mini-pool testing, pools >= 50 RNA copies per ml achieved >= 92 % sensitivity, whereas in the standard procedure, samples >= 207 RNA copies/ml achieved 100 % sensitivity. Moreover, the COBAS AmpliScreen (TM) HIV-1 Test, version 1.5 (Roche) is suitable for detecting prevailing HIV-1 variants. (C) 2014 Asociacion Argentina de Microbiologia. Published by Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:196 / 200
页数:5
相关论文
共 50 条
  • [41] Comparison of the bioMerieux NucliSENS EasyQ HIV-1 v2.0-HIV-1 RNA quantification assay versus Abbott RealTime HIV-1 and Roche Cobas TaqMan HIV-1 v2.0 on current epidemic HIV-1 variants
    Mourez, Thomas
    Delaugerre, Constance
    Vray, Muriel
    Lemee, Veronique
    Simon, Francois
    Plantier, Jean-Christophe
    JOURNAL OF CLINICAL VIROLOGY, 2015, 71 : 76 - 81
  • [42] Evaluation of the Roche COBAS® TaqMan® HIV-1 test for quantifying HIV-1 RNA in infected cells and lymphoid tissue
    Gil, Cristina
    Teresa Garcia, M.
    Garcia, Felipe
    Miro, Jose M.
    Agueero, Fernando
    Alos, Lucia
    Zamora, Laura
    Capon, Alicia
    Costa, Josep
    Pumarola, Tomas
    Gatell, Jose M.
    JOURNAL OF VIROLOGICAL METHODS, 2011, 174 (1-2) : 69 - 76
  • [43] Evaluation of COBAS AmpliPrep nucleic acid extraction in conjunction with COBAS AmpliScreen HBV DNA, HCV RNA and HIV-1 RNA amplification and detection
    Koppelman, MHGM
    Sjerps, MC
    Reesink, HW
    Cuypers, HTM
    VOX SANGUINIS, 2005, 89 (04) : 193 - 200
  • [44] Analytical characteristics and comparative evaluation of Aptima HIV-1 Quant Dx assay with Ampliprep/COBAS TaqMan HIV-1 test v2.0
    Angelos. Hatzakis
    Helen Papachristou
    Sangeetha J. Nair
    Jacqueline Fortunko
    Tracy Foote
    HeeCheol Kim
    Tashi L. Peling
    Andrew J. Worlock
    Virology Journal, 13
  • [45] Comparison of the Hologic Aptima HIV-1 Quant Dx assay to the Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Test v2.0 for the quantification of HIV-RNA in plasma samples
    Schonning, K.
    Johansen, K.
    Landt, B.
    Benfield, T.
    Westh, H.
    JOURNAL OF CLINICAL VIROLOGY, 2016, 82 : S53 - S53
  • [46] Analytical characteristics and comparative evaluation of Aptima HIV-1 Quant Dx assay with Ampliprep/COBAS TaqMan HIV-1 test v2.0
    Hatzakis, Angelos.
    Papachristou, Helen
    Nair, Sangeetha J.
    Fortunko, Jacqueline
    Foote, Tracy
    Kim, HeeCheol
    Peling, Tashi L.
    Worlock, Andrew J.
    VIROLOGY JOURNAL, 2016, 13
  • [47] Evaluation of the NucliSens EasyQ v2.0 Assay in Comparison with the Roche Amplicor v1.5 and the Roche CAP/CTM HIV-1 Test v2.0 in Quantification of C-Clade HIV-1 in Plasma
    Muenchhoff, Maximilian
    Madurai, Savathee
    Hempenstall, Allison Jo
    Adland, Emily
    Carlqvist, Anna
    Moonsamy, Angeline
    Jaggernath, Manjeetha
    Mlotshwa, Busisiwe
    Siboto, Emma
    Ndung'u, Thumbi
    Goulder, Philip Jeremy Renshaw
    PLOS ONE, 2014, 9 (08):
  • [48] Comparison of the Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 and the Seimens Versant bDNA HIV-1 Version 3.0
    Dokus, B. J.
    Marchetti, A. L.
    Bentley, H. A.
    Bartels, C. L.
    Tsongalis, G. J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2009, 11 (06): : 639 - 639
  • [49] Comparison of the Generic HIV Viral Load® assay with the Amplicor™ HIV-1 Monitor v1.5 and Nuclisens HIV-1 EasyQ® v1.2 techniques for plasma HIV-1 RNA quantitation of non-B subtypes: The Kesho Bora preparatory study
    Rouet, Francois
    Foulongne, Vincent
    Viljoen, Johannes
    Steegen, Kim
    Becquart, Pierre
    Valea, Diane
    Danaviah, Sivapragashini
    Segondy, Michel
    Verhofstede, Chris
    Van de Perre, Philippe
    JOURNAL OF VIROLOGICAL METHODS, 2010, 163 (02) : 253 - 257
  • [50] Multicenter evaluation of the cobas® HIV-1 quantitative nucleic acid test for use on the cobas® 4800 system for the quantification of HIV-1 plasma viral load
    Adams, Phillip
    Vancutsem, Ellen
    Nicolaizeau, Cyrielle
    Servais, Jean-Yves
    Pierard, Denis
    Francois, Jean-Hugues
    Schneider, Tanja
    Paxinos, Ellen E.
    Marins, Ed G.
    Canchola, Jesse A.
    Seguin-Devaux, Carole
    JOURNAL OF CLINICAL VIROLOGY, 2019, 114 : 43 - 49