Sensitivity of the COBAS AmpliScreen™ HIV-1 Test v1.5 for HIV-1 detection

被引:0
|
作者
Gomez, Lucia P. [1 ,2 ]
Balangero, Marcos C. [1 ,2 ]
Castro, Gonzalo [1 ,3 ]
Kademian, Silvia [3 ]
Mangeaud, Arnaldo [4 ]
Barbas, Maria G. [3 ]
Cudola, Analia [3 ]
de Leon, Juan F. [2 ,3 ]
Carrizo, Horacio [2 ]
Gallego, Sandra V. [1 ,2 ,3 ]
机构
[1] Univ Nacl Cordoba UNC, Fac Ciencias Med, Inst Virol Dr JM Vanella, Lab Virus Linfotrop Humanos Retrovirus HIV & HTLV, Cordoba, Argentina
[2] Fdn Banco Cent Sangre, Lab Biol Mol, Cordoba, Argentina
[3] Minist Salud, Lab Cent Prov Cordoba, Cordoba, Argentina
[4] UNC, Catedra Estadist & Biometria, Fac Ciencias Exactas Fis & Nat, Cordoba, Argentina
来源
REVISTA ARGENTINA DE MICROBIOLOGIA | 2014年 / 46卷 / 03期
关键词
NAT; HIV-1; COBAS AmpliScreen; HUMAN-IMMUNODEFICIENCY-VIRUS; BLOOD-DONATIONS; AMPLIFICATION; ARGENTINA; MULTICENTER; INFECTIONS; DONOR; ASSAY; RNA; DNA;
D O I
10.1016/S0325-7541(14)70072-0
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The introduction of nucleic acid amplification techniques (NAT) in blood banks was intended to reduce the residual risk of transfusion-transmitted infections. Co-circulation of a great diversity of HIV-1 variants in Argentina portrays the need to assess the sensitivity of serological and molecular assays available for their detection. In this study, we evaluated the sensitivity of the COBAS AmpliScreen (TM) HIV-1 Test, version 1.5 (Roche) for the detection of HIV-1 RNA in plasma samples of infected individuals from Argentina. The results of this study reveal that this technique has high sensitivity for the detection of HIV-1 RNA under assay conditions: using mini-pool testing, pools >= 50 RNA copies per ml achieved >= 92 % sensitivity, whereas in the standard procedure, samples >= 207 RNA copies/ml achieved 100 % sensitivity. Moreover, the COBAS AmpliScreen (TM) HIV-1 Test, version 1.5 (Roche) is suitable for detecting prevailing HIV-1 variants. (C) 2014 Asociacion Argentina de Microbiologia. Published by Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:196 / 200
页数:5
相关论文
共 50 条
  • [21] Evaluation of an Upgraded Version of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Test for HIV-1 Load Quantification
    Damond, F.
    Avettand-Fenoel, V.
    Collin, G.
    Roquebert, B.
    Plantier, J. C.
    Ganon, A.
    Sizmann, D.
    Babiel, R.
    Glaubitz, J.
    Chaix, M. L.
    Brun-Vezinet, F.
    Descamps, D.
    Rouzioux, C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (04) : 1413 - 1416
  • [22] Workflow and cost comparison of COBAS AmpliPrep/COBAS TaqMan HIV-1 test and Abbott ReaITime HIV-1 assay
    Sloma, C. R.
    Gerads, T. M.
    Germer, J. J.
    Mitchell, P. S.
    Yao, J. D.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2007, 9 (05): : 674 - 675
  • [23] Comparison of HIV-1 Detection in Plasma Specimens and Dried Blood Spots Using the Roche COBAS Ampliscreen HIV-1 Test: Implications for Blood Banking in Resource-Limited Settings
    Okonji, J. A.
    Basavaraju, S. V.
    Shiraishi, R. W.
    Pitman, J. P.
    Ou, C.
    Zeh, C.
    TRANSFUSION, 2011, 51 : 216A - 216A
  • [24] Comparison of the Hologic Aptima HIV-1 Quant Dx Assay to the Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Test v2.0 for the quantification of HIV-1 RNA in plasma samples
    Schonning, Kristian
    Johansen, Kim
    Landt, Bodil
    Benfield, Thomas
    Westh, Henrik
    JOURNAL OF CLINICAL VIROLOGY, 2017, 92 : 14 - 19
  • [25] Human immunodeficiency virus type 1 (HIV-1) plasma load discrepancies between the Roche COBAS AMPLICOR HIV-1 MONITOR version 1.5 and the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 assays
    Damond, F.
    Roquebert, B.
    Benard, A.
    Collin, G.
    Miceli, A.
    Yeni, P.
    Brun-Vezinet, F.
    Descamps, D.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (10) : 3436 - 3438
  • [26] Evaluation of the Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor™ Ultrasensitive Test:: comparison with the Cobas Amplicor HIV-1 Monitor™ test (manual specimen preparation)
    Berger, A
    Scherzed, L
    Stürmer, M
    Preiser, W
    Doerr, HW
    Rabenau, HF
    JOURNAL OF CLINICAL VIROLOGY, 2002, 25 : S103 - S107
  • [27] Comparison of the Aptima HIV-1 Quant Dx assay with the COBAS AmpliPrep/COBAS TaqMan HIV-1 v2.0 Test for HIV-1 viral load quantification in plasma samples from HIV-1-infected patients
    Longo, Serena
    Bon, Isabella
    Musumeci, Giuseppina
    Bertoldi, Alessia
    D'Urbano, Vanessa
    Calza, Leonardo
    Re, Maria Carla
    HEALTH SCIENCE REPORTS, 2018, 1 (04)
  • [28] 1.5版COBAS AmpliScreen检测HIV-1的性能特征,用于微混合血浆筛选
    周庆申
    国外医学输血及血液学分册., 2002, (01) : 91 - 92
  • [29] Comparative evaluation of the Cobas Amplicor HIV-1 Monitor™ ultrasensitive test, the new Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor™ ultrasensitive test and the versant HIV RNA 3.0 assays for quantitation of HIV-1 RNA in plasma samples
    Berger, A
    Scherzed, L
    Sturmer, M
    Preiser, W
    Doerr, HW
    Rabenau, HF
    JOURNAL OF CLINICAL VIROLOGY, 2005, 33 (01) : 43 - 51
  • [30] Comparison of Abbott RealTime HIV-1 and Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 Assays
    Abravaya, K.
    Hackett, J.
    Swanson, P.
    Huang, S.
    Tang, N.
    Robinson, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2008, 10 (06): : 587 - 587