Predicting conversion to glaucoma using standard automated perimetry and frequency doubling technology

被引:4
|
作者
Takahashi, Genichiro [1 ]
Demirel, Shaban [2 ]
Johnson, Chris A. [3 ]
机构
[1] Jikei Univ, Sch Med, Dept Ophthalmol, Katsushika Med Ctr, Tokyo, Japan
[2] Devers Eye Inst, Discoveries Sight Res Labs, Portland, OR USA
[3] Univ Iowa Hosp & Clin, Dept Ophthalmol & Visual Sci, 200 Hawkins Dr, Iowa City, IA 52242 USA
关键词
Visual fields; Glaucoma; Frequency doubling; Progression; VISUAL-FIELD DEFECTS; OCULAR HYPERTENSION; SPATIAL-FREQUENCY; MACAQUE MONKEY; GANGLION-CELLS; PROGRESSION; ILLUSION; LOSSES; TRIAL; EYES;
D O I
10.1007/s00417-016-3573-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To test the hypothesis that development of glaucomatous visual fields can be predicted several years earlier from prior visual field information. One-hundred and seven eyes with glaucomatous optic neuropathy (n = 47 eyes) or which were suspicious for glaucoma (n = 60) were prospectively enrolled in a longitudinal study. Visual fields were evaluated on an annual basis using standard automated perimetry (SAP), the original version of frequency doubling technology (FDT) perimetry, and a custom version of FDT that used the 24-2 stimulus pattern. All SAP fields were within normal limits at the initial visit. When the SAP glaucoma hemifield test was 'outside normal limits' or the pattern standard deviation probability was worse than the lower 5th percentile or more than two clustered locations at the p < 0.05 level were present on the pattern deviation probability plot, an eye was defined as being abnormal. We used a classification tree analysis to predict which eyes would convert, using only baseline test results. Classification trees that were constructed using only baseline data had excellent specificity (near 100%) but worse sensitivity (25-50%) for predicting which eyes would convert during follow-up. Predictive information is present in visual field results, even when they are still within normal limits.
引用
收藏
页码:797 / 803
页数:7
相关论文
共 50 条
  • [41] Alterations Induced by Bangerter Filters on the Visual Field: A Frequency Doubling Technology and Standard Automated Perimetry Study
    Schiavi, Costantino
    Tassi, Filippo
    Finzi, Alessandro
    Cellini, Andmauro
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [42] Comparison of Humphrey Matrix Frequency Doubling Technology to Standard Automated Perimetry in Neuro-ophthalmic Disease
    Yoon, Michael K.
    Hwang, Thomas N.
    Day, Shelley
    Hong, Jenny
    Porco, Travis
    McCulley, Timothy J.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2012, 19 (02) : 211 - 215
  • [43] Frequency Doubling Technology for Earlier Detection of Functional Damage in Standard Automated Perimetry-Normal Hemifield in Glaucoma With Low-to-Normal Pressure
    Nakagawa, Suguru
    Murata, Hiroshi
    Saito, Hitomi
    Nakahara, Hisae
    Mataki, Naomi
    Tomidokoro, Atsuo
    Iwase, Aiko
    Araie, Makoto
    JOURNAL OF GLAUCOMA, 2012, 21 (01) : 22 - 26
  • [44] Frequency doubling perimetry in glaucoma early diagnosis
    Brusini, P
    Busatto, P
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 : 23 - 24
  • [45] Diagnosing glaucoma from frequency doubling technology perimetry using supervised machine learning classifiers
    Pascual, JP
    Zhang, Z
    Hughes, AJ
    Hao, J
    Lee, TW
    Sejnowski, T
    Goldbaum, MH
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U780 - U780
  • [46] Correlation between frequency doubling technology perimetry and temporal frequency characteristics in early glaucoma*
    Joseph Jy-Haw Yu
    Motohiro Kiyosawa
    Nobuyuki Nemoto
    Keiko Momose
    Hiroshi Mori
    Manabu Mochizuki
    Documenta Ophthalmologica, 2003, 107 : 93 - 99
  • [47] Performance of frequency doubling perimetry in screening for glaucoma
    Weih, L
    Sakellariou, A
    Rait, J
    McCarty, C
    Taylor, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S477 - S477
  • [48] Correlation between frequency doubling technology perimetry and temporal frequency characteristics in early glaucoma
    Yu, JJH
    Kiyosawa, M
    Nemoto, N
    Momose, K
    Mori, H
    Mochizuki, M
    DOCUMENTA OPHTHALMOLOGICA, 2003, 107 (02) : 93 - 99
  • [49] Frequency doubling perimetry in glaucoma early diagnosis
    De Gregorio, F
    Trani, M
    Sedran, L
    Virno, M
    Pannarale, MR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S69 - S69
  • [50] Detection of early visual field loss in glaucoma using frequency-doubling perimetry and short-wavelength automated perimetry
    Landers, JA
    Goldberg, I
    Graham, SL
    ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (12) : 1705 - 1710