Predicting conversion to glaucoma using standard automated perimetry and frequency doubling technology

被引:4
|
作者
Takahashi, Genichiro [1 ]
Demirel, Shaban [2 ]
Johnson, Chris A. [3 ]
机构
[1] Jikei Univ, Sch Med, Dept Ophthalmol, Katsushika Med Ctr, Tokyo, Japan
[2] Devers Eye Inst, Discoveries Sight Res Labs, Portland, OR USA
[3] Univ Iowa Hosp & Clin, Dept Ophthalmol & Visual Sci, 200 Hawkins Dr, Iowa City, IA 52242 USA
关键词
Visual fields; Glaucoma; Frequency doubling; Progression; VISUAL-FIELD DEFECTS; OCULAR HYPERTENSION; SPATIAL-FREQUENCY; MACAQUE MONKEY; GANGLION-CELLS; PROGRESSION; ILLUSION; LOSSES; TRIAL; EYES;
D O I
10.1007/s00417-016-3573-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To test the hypothesis that development of glaucomatous visual fields can be predicted several years earlier from prior visual field information. One-hundred and seven eyes with glaucomatous optic neuropathy (n = 47 eyes) or which were suspicious for glaucoma (n = 60) were prospectively enrolled in a longitudinal study. Visual fields were evaluated on an annual basis using standard automated perimetry (SAP), the original version of frequency doubling technology (FDT) perimetry, and a custom version of FDT that used the 24-2 stimulus pattern. All SAP fields were within normal limits at the initial visit. When the SAP glaucoma hemifield test was 'outside normal limits' or the pattern standard deviation probability was worse than the lower 5th percentile or more than two clustered locations at the p < 0.05 level were present on the pattern deviation probability plot, an eye was defined as being abnormal. We used a classification tree analysis to predict which eyes would convert, using only baseline test results. Classification trees that were constructed using only baseline data had excellent specificity (near 100%) but worse sensitivity (25-50%) for predicting which eyes would convert during follow-up. Predictive information is present in visual field results, even when they are still within normal limits.
引用
收藏
页码:797 / 803
页数:7
相关论文
共 50 条
  • [31] The distribution of visual field defects per quadrant in standard automated perimetry as compared to frequency doubling technology perimetry
    Zein W.M.
    Bashshur Z.F.
    Jaafar R.F.
    Noureddin B.N.
    International Ophthalmology, 2010, 30 (6) : 683 - 689
  • [32] Comparison of frequency doubling technology perimetry and achromatic standard automated perimetry in patients with migraine without aura and controls
    Goebel, K.
    Boyraz, M.
    Schroeder, A.
    Erb, C.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2008, 225 (08) : 718 - 722
  • [33] Prediction of future scotoma on conventional automated static perimetry using frequency doubling technology perimetry
    Kogure, S
    Toda, Y
    Tsukahara, S
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (03) : 347 - 352
  • [34] Spatial relationship of defects in frequency doubling technology perimetry and standard achromatic perimetry
    Pascual, JP
    Sample, PA
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U489 - U489
  • [35] Standard Automated Perimetry versus Matrix Frequency Doubling Technology Perimetry in Subjects with Ocular Hypertension and Healthy Control Subjects
    Lamparter, Julia
    Aliyeva, Shakhsanam
    Schulze, Andreas
    Berres, Manfred
    Pfeiffer, Norbert
    Hoffmann, Esther M.
    PLOS ONE, 2013, 8 (02):
  • [36] Comparison of Glaucoma Detection Performance of Binocular Perimetry Screening Program Using imo Perimetry With Frequency Doubling Technology
    Nishijima, Euido
    Hosaka, Daisuke
    Ogawa, Shumpei
    Itoh, Yoshinori
    Noro, Takahiko
    Okude, Sachiyo
    Sano, Kei
    Yoshikawa, Keiji
    Tatemichi, Masayuki
    Nakano, Tadashi
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (08):
  • [37] Long-term fluctuation of standard automatic perimetry, pulsar Perimetry and frequency-doubling technology in early glaucoma diagnosis
    Gonzalez-Hernandez, M.
    de la Rosa, M. Gonzalez
    de la Vega, R. Rodriguez
    Hernandez-Vidal, A.
    OPHTHALMIC RESEARCH, 2007, 39 (06) : 338 - 343
  • [38] Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma
    Siddiqui, MAR
    Azuara-Blanco, A
    Neville, S
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (12) : 1569 - 1571
  • [39] Prediction of visual field defects on standard automated perimetry by screening C-20-1 frequency doubling technology perimetry
    Kamantigue, MEG
    Joson, PJ
    Chen, PP
    JOURNAL OF GLAUCOMA, 2006, 15 (01) : 35 - 39
  • [40] Comparison of standard automated perimetry with matrix frequency-doubling technology in patients with resolved optic neuritis
    Sakai, Tsutoinu
    Matsushima, Masato
    Shikishima, Keigo
    Kitahara, Kenji
    OPHTHALMOLOGY, 2007, 114 (05) : 949 - 956