Setup accuracy and dose attenuation of a wooden immobilization system for lung stereotactic body radiotherapy

被引:1
|
作者
Nitta, Yuya [1 ]
Ueda, Yoshihiro [1 ]
Murata, Seiya [1 ]
Isono, Masaru [1 ]
Ohira, Shingo [1 ]
Masaoka, Akira [1 ]
Inui, Shoki [1 ,2 ]
Washio, Hayate [3 ,4 ]
Yoshinaka, Reimi [1 ]
Sagawa, Tomohiro [1 ]
Miyazaki, Masayoshi [1 ]
Teshima, Teruki [5 ]
机构
[1] Osaka Int Canc Inst, Dept Radiat Oncol, Osaka, Japan
[2] Osaka Univ, Grad Sch, Dept Med Phys & Engn, Osaka, Japan
[3] Osaka Int Canc Inst, Dept Radiol, Osaka, Japan
[4] Kumamoto Univ, Grad Sch Hlth Sci, Kumamoto, Japan
[5] Osaka Heavy Ion Therapy Ctr, Osaka, Japan
关键词
lung SBRT; wooden baseplate; setup verification; IMAGE-GUIDED RADIOTHERAPY; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; CANCER; LOCALIZATION; DEVICES; ERRORS;
D O I
10.5603/RPOR.a2022.0089
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: We evaluated the setup error and dose absorption of an immobilization system with a shell and wooden baseplate (SW) for lung stereotactic body radiotherapy (SBRT). Materials and methods: Setup errors in 109 patients immobilized with an SW or BodyFix system (BF) were compared. Dose attenuation rates of materials for baseplates were measured with an ion-chamber. Ionization measurements were performed from 90 degrees to 180 degrees gantry angle in 10 degrees increments, with the ball water equivalent phantom placed at the center of the wood and carbon baseplates whose effects on dose distribution were compared using an electron portal imaging device. Results: The ratio for the anterior-posterior, cranial-caudal, and right-left of the cases within 3-mm registered shifts in interfractional setup error were 90.9%, 89.2%, and 97.4% for the SW, and 93.2%, 91.6%, and 98.0% for the BF, respectively. For intrafractional setup error, 98.3%, 97.4%, and 99.1% for the SW and 96.6%, 95.8%, and 98.7% for the BF were within 3-mm registered shifts, respectively. In the center position, the average (minimum/maximum) dose attenuation rates from 90 degrees to 180 degrees for the wooden and carbon baseplates were 0.5 (0.1/2.8)% and 1.0 (-0.1/10.1)% with 6 MV, respectively. The gamma passing rates of 2%/2 mm for the wooden and carbon baseplates were 99.7% and 98.3% (p < 0.01). Conclusions: The immobilization system with an SW is effective for lung SBRT since it is comparable to the BF in setup accuracy. Moreover, the wooden baseplate had lower radiation attenuation rates and affected the dose distribution less than the carbon baseplate.
引用
收藏
页码:809 / 820
页数:12
相关论文
共 50 条
  • [21] Survival Impact of Cardiac Dose Following Lung Stereotactic Body Radiotherapy
    Wong, Olive Y.
    Yau, Vivian
    Kang, Julie
    Glick, Daniel
    Lindsay, Patricia
    Le, Lisa W.
    Sun, Alexander
    Bezjak, Andrea
    Cho, B. C. John
    Hope, Andrew
    Giuliani, Meredith
    CLINICAL LUNG CANCER, 2018, 19 (02) : E241 - E246
  • [22] High dose hypofractionated stereotactic body radiotherapy for oligometastatic lung cancer
    Bergantin, A.
    Bianchi, L. C.
    Martinotti, A. S.
    Vite, C.
    Ria, F.
    Invernizzi, M.
    Beltramo, G.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S43 - S43
  • [23] Evaluation of Repeated Lung Stereotactic Body Radiotherapy Using a Radiotherapy Dose Accumulation Routine
    Hong, J.
    Yorke, E. D.
    Kuo, L.
    Hu, Y. C.
    Li, X.
    Wu, A. J.
    Liu, Y.
    Mechalakos, J. G.
    Zhang, P.
    Cervino, L. I.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E573 - E573
  • [24] Influence of the Couch and Immobilization Device used during Stereotactic Body Radiotherapy on Skin Dose
    Gao, S.
    Chang, J. Y.
    Welsh, J.
    Komaki, R.
    Balter, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S682 - S682
  • [25] Accuracy of stereotactic body radiotherapy dose calculation algorithms outside treatment field
    Viren, T.
    Salomaa, S.
    Seppala, J.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S476 - S477
  • [26] Accuracy of treatment planning system and delivery of dose in extracranial stereotactic radiotherapy
    Dawod, T.
    Werner, M.
    Bremer, M.
    Karstens, J. H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 105 - 106
  • [27] Targeting accuracy of an image guided gating system for stereotactic body radiotherapy
    Tenn, SE
    Solberg, TD
    Medin, PM
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (23): : 5443 - 5462
  • [28] Lung reirradiation with stereotactic body radiotherapy
    Maranzano, Ernesto
    Draghini, Lorena
    Anselmo, Paola
    Casale, Michelina
    Arcidiacono, Fabio
    Chirico, Luigia
    Italiani, Marco
    Trippa, Fabio
    JOURNAL OF RADIOSURGERY AND SBRT, 2016, 4 (01): : 61 - 68
  • [29] Stereotactic body radiotherapy for lung cancer
    Nagata, Y
    Hiraoka, M
    LUNG CANCER, 2004, 46 : S33 - S33
  • [30] Factors affecting bony anatomy setup errors for lung Stereotactic Ablative Body Radiotherapy (SABR)
    Quinn, Emily
    Bennett, Erica
    Barry, Laura
    England, Andrew
    Devine, Annemarie
    McEntee, Mark
    O'Donovan, Theresa
    Kelly, Paul
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S5613 - S5615