A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Branemark system implants

被引:60
|
作者
Turkyilmaz, I.
机构
[1] Hacettepe Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[2] Univ Gothenburg, Inst Surg Sci, Dept Biomat, Gothenburg, Sweden
关键词
dental implant; insertion torque; resonance frequency; correlation; early loading;
D O I
10.1111/j.1365-2842.2006.01631.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to determine primary stability and insertion torque of Branemark System implants placed in the anterior mandible, and to evaluate a possible correlation between primary stability and insertion torque. Thirty edentulous patients were treated with 60 Branemark System implants using a one-stage technique. The insertion torque values of all implants were recorded with the Osseocare equipment. Immediately after implant placement, each implant was connected to the transducer of an Osstell machine to measure the primary implant stability. The average insertion torque and resonance frequency values were 41.5 +/- 5.8 and 74.1 +/- 3.8 for 30 implants. The correlation between insertion torque and resonance frequency values indicated a statistical significance (P < 0.001). The difference between mean insertion torque values for female and male patients was statistically significant (P < 0.001). No significant difference (P > 0.05) was found between younger and older patients with mean insertion torque values of 43.1 +/- 4.7 and 40.1 +/- 6.5 respectively. The results of this study showed a strong correlation between the primary stability and insertion torque values of Branemark System TiUnite MKIII implants at the time of implant placement.
引用
收藏
页码:754 / 759
页数:6
相关论文
共 50 条
  • [31] Development of a New Implant Primary Stability Parameter: Insertion Torque Revisited
    Degidi, Marco
    Daprile, Giuseppe
    Piattelli, Adriano
    Iezzi, Giovanna
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (05) : 637 - 644
  • [32] Torque Ratio as a Predictable Factor on Primary Stability of Orthodontic Miniscrew Implants
    Inoue, Masahide
    Kuroda, Shingo
    Yasue, Akihiro
    Horiuchi, Shinya
    Kyung, Hee-Moon
    Tanaka, Eiji
    IMPLANT DENTISTRY, 2014, 23 (05) : 576 - 581
  • [33] Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design
    Baldi, Domenico
    Lombardi, Teresa
    Colombo, Jacopo
    Cervino, Gabriele
    Perinetti, Giuseppe
    Di Lenarda, Roberto
    Stacchi, Claudio
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [34] Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides
    Sul, YT
    Johansson, CB
    Jeong, Y
    Wennerberg, A
    Albrektsson, T
    CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) : 252 - 259
  • [35] Insertion torque and resonance frequency analysis (ISQ) as predictor methods of implant osseointegration
    Gahona, O.
    Granic, X.
    Antunez, C.
    Domancic, S.
    Diaz-Narvaez, V.
    Utsman, R.
    JOURNAL OF OSSEOINTEGRATION, 2018, 10 (03) : 103 - 107
  • [36] Influence of Bone Quality, Drilling Protocol, Implant Diameter/Length on Primary Stability: An In Vitro Comparative Study on Insertion Torque and Resonance Frequency Analysis
    Farronato, Davide
    Manfredini, Mattia
    Stocchero, Michele
    Caccia, Mattia
    Azzi, Lorenzo
    Farronato, Marco
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (03) : 182 - 189
  • [37] Insertion Torque (IT) and Implant Stability Quotient (ISQ) Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study
    Mello, Bruno Freitas
    Formiga, Marcio De Carvalho
    Bianchini, Marco Aurelio
    Borges Jr, Ivan
    Coura, Gustavo
    Tumedei, Margherita
    Fuller, Renato
    Petrini, Morena
    Romasco, Tea
    Vaz, Paula
    Piattelli, Adriano
    Di Pietro, Natalia
    APPLIED SCIENCES-BASEL, 2023, 13 (18):
  • [38] Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis
    Falco, Antonello
    Berardini, Marco
    Trisi, Paolo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (04) : 824 - 830
  • [39] The Correlation Between Immediate Implant Insertion Torque and Implant Stability Quotient
    Levin, Barry P.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2016, 36 (06) : 833 - 840
  • [40] PRIMARY STABILITY OF INTERFERENCE SCREW FIXATION - INFLUENCE OF SCREW DIAMETER AND INSERTION TORQUE
    KOHN, D
    ROSE, C
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (03): : 334 - 338