A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Branemark system implants

被引:60
|
作者
Turkyilmaz, I.
机构
[1] Hacettepe Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[2] Univ Gothenburg, Inst Surg Sci, Dept Biomat, Gothenburg, Sweden
关键词
dental implant; insertion torque; resonance frequency; correlation; early loading;
D O I
10.1111/j.1365-2842.2006.01631.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to determine primary stability and insertion torque of Branemark System implants placed in the anterior mandible, and to evaluate a possible correlation between primary stability and insertion torque. Thirty edentulous patients were treated with 60 Branemark System implants using a one-stage technique. The insertion torque values of all implants were recorded with the Osseocare equipment. Immediately after implant placement, each implant was connected to the transducer of an Osstell machine to measure the primary implant stability. The average insertion torque and resonance frequency values were 41.5 +/- 5.8 and 74.1 +/- 3.8 for 30 implants. The correlation between insertion torque and resonance frequency values indicated a statistical significance (P < 0.001). The difference between mean insertion torque values for female and male patients was statistically significant (P < 0.001). No significant difference (P > 0.05) was found between younger and older patients with mean insertion torque values of 43.1 +/- 4.7 and 40.1 +/- 6.5 respectively. The results of this study showed a strong correlation between the primary stability and insertion torque values of Branemark System TiUnite MKIII implants at the time of implant placement.
引用
收藏
页码:754 / 759
页数:6
相关论文
共 50 条
  • [21] Primary Stability Determination by Means of Insertion Torque and RFA in a Sample of 4,135 Implants
    Degidi, Marco
    Daprile, Giuseppe
    Piattelli, Adriano
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (04) : 501 - 507
  • [22] High insertion torque versus regular insertion torque: early crestal bone changes on dental implants in relation to primary stability-a retrospective clinical study
    Ruppin, Joerg-Martin
    Stimmelmayr, Michael
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [23] A comparison between cutting torque and resonance frequency measurements of maxillary implants - A 20-month clinical study
    Friberg, B
    Sennerby, L
    Meredith, N
    Lekholm, U
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 28 (04) : 297 - 303
  • [24] Insertion Torque, Removal Torque, and Resonance Frequency Analysis Values of Ultrashort, Short, and Standard Dental Implants: An In Vitro Study on Polyurethane Foam Sheets
    Comuzzi, Luca
    Tumedei, Margherita
    Romasco, Tea
    Petrini, Morena
    Afrashtehfar, Kelvin I.
    Inchingolo, Francesco
    Piattelli, Adriano
    Di Pietro, Natalia
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (01)
  • [25] Implant Primary Stability Determined by Resonance Frequency Analysis: Correlation With Insertion Torque, Histologic Bone Volume, and Torsional Stability at 6 Weeks
    Makary, Christian
    Rebaudi, Alberto
    Sammartino, Gilberto
    Naaman, Nada
    IMPLANT DENTISTRY, 2012, 21 (06) : 474 - 480
  • [26] Analysis of Primary Stability of Dental Implants Inserted in Different Substrates Using the Pullout Test and Insertion Torque
    Oliscovicz, Nathalia Ferraz
    Shimano, Antonio Carlos
    Marcantonio Junior, Elcio
    Lepri, Cesar Penazzo
    dos Reis, Andrea Candido
    INTERNATIONAL JOURNAL OF DENTISTRY, 2013, 2013
  • [27] Insertion torque/time integral as a measure of primary implant stability
    Grobecker-Karl, Tanja
    Karl, Matthias
    Steiner, Constanze
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2020, 65 (06): : 729 - 733
  • [28] Relationship Between Primary Stability and Crestal Bone Loss of Implants Placed with High Insertion Torque: A 3-Year Prospective Study
    De Santis, Daniele
    Cucchi, Alessandro
    Rigoni, Giovanni
    Longhi, Carlo
    Nocini, Pier Francesco
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) : 1126 - 1134B
  • [29] An In Vitro Analysis on Polyurethane Foam Blocks of the Insertion Torque (IT) Values, Removal Torque Values (RTVs), and Resonance Frequency Analysis (RFA) Values in Tapered and Cylindrical Implants
    Comuzzi, Luca
    Tumedei, Margherita
    D'Arcangelo, Camillo
    Piattelli, Adriano
    Iezzi, Giovanna
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (17)
  • [30] An In Vitro Evaluation, on Polyurethane Foam Sheets, of the Insertion Torque (IT) Values, Pull-Out Torque Values, and Resonance Frequency Analysis (RFA) of NanoShort Dental Implants
    Comuzzi, Luca
    Iezzi, Giovanna
    Piattelli, Adriano
    Tumedei, Margherita
    POLYMERS, 2019, 11 (06)