A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Branemark system implants

被引:60
|
作者
Turkyilmaz, I.
机构
[1] Hacettepe Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[2] Univ Gothenburg, Inst Surg Sci, Dept Biomat, Gothenburg, Sweden
关键词
dental implant; insertion torque; resonance frequency; correlation; early loading;
D O I
10.1111/j.1365-2842.2006.01631.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to determine primary stability and insertion torque of Branemark System implants placed in the anterior mandible, and to evaluate a possible correlation between primary stability and insertion torque. Thirty edentulous patients were treated with 60 Branemark System implants using a one-stage technique. The insertion torque values of all implants were recorded with the Osseocare equipment. Immediately after implant placement, each implant was connected to the transducer of an Osstell machine to measure the primary implant stability. The average insertion torque and resonance frequency values were 41.5 +/- 5.8 and 74.1 +/- 3.8 for 30 implants. The correlation between insertion torque and resonance frequency values indicated a statistical significance (P < 0.001). The difference between mean insertion torque values for female and male patients was statistically significant (P < 0.001). No significant difference (P > 0.05) was found between younger and older patients with mean insertion torque values of 43.1 +/- 4.7 and 40.1 +/- 6.5 respectively. The results of this study showed a strong correlation between the primary stability and insertion torque values of Branemark System TiUnite MKIII implants at the time of implant placement.
引用
收藏
页码:754 / 759
页数:6
相关论文
共 50 条
  • [1] Evaluation of primary stability in modified implants: Analysis by resonance frequency and insertion torque
    Sciasci, Plinio
    Casalle, Nicole
    Vaz, Luis Geraldo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (03) : 274 - 279
  • [2] A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single tooth implants under immediate loading
    da Cunha, HA
    Francischone, CE
    Nary, H
    de Oliveira, RCG
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (04) : 578 - 585
  • [3] Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants
    Kahraman, S.
    Bal, B. T.
    Asar, N. V.
    Turkyilmaz, I.
    Tozum, T. F.
    JOURNAL OF ORAL REHABILITATION, 2009, 36 (10) : 755 - 761
  • [4] Assessment of the Correlation Between Insertion Torque and Resonance Frequency Analysis of Implants Placed in Bone Tissue of Different Densities
    Magno Filho, Luiz Carlos
    Cirano, Fabiano Ribeiro
    Hayashi, Fernando
    Feng, Hsu Shao
    Conte, Alexandre
    Dib, Luciano Lauria
    Casati, Marcio Zaffalon
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (03) : 259 - 262
  • [5] Insertion Torque and Resonance Frequency Analysis in Tapered and Parallel Dental Implants
    Oliveros, Joaquin de Elio
    Garcia, Alejandro Gago
    Sacristan, Hernan Lopez
    Diez, Patricia Truchuelo
    Martin, Cayetana Barrilero
    Diaz, Mariano del Canto
    Pingarron, Mariano del Canto
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (04) : 347 - 354
  • [7] A comparison between cutting torque and resonance frequency measurements of mandibular implants.
    Pessoa, T
    Nary, HF
    Francischone, CE
    Falcao, R
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 131 - 131
  • [8] Comparison of Primary Stability of Straight-Walled and Tapered Implants Using an Insertion Torque Device
    Menicucci, Giulio
    Pachie, Emanuela
    Lorenzetti, Massimo
    Migliaretti, Giuseppe
    Carossa, Stefano
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (05) : 465 - 471
  • [9] Insertion torque, resonance frequency, and removal torque analysis of microimplants
    Tseng, Yu-Chuan
    Ting, Chun-Chan
    Du, Je-Kang
    Chen, Chun-Ming
    Wu, Ju-Hui
    Chen, Hong-Sen
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2016, 32 (09): : 469 - 474
  • [10] Relationship Between Insertion Torque and Resonance Frequency Measurements, Performed by Resonance Frequency Analysis, in Micromobility of Dental Implants: An In Vitro Study
    Brizuela-Velasco, Aritza
    Alvarez-Arenal, Angel
    Javier Gil-Mur, Francisco
    Herrero-Climent, Mariano
    Chavarri-Prado, David
    Chento-Valiente, Yelko
    Dieguez-Pereira, Markel
    IMPLANT DENTISTRY, 2015, 24 (05) : 607 - 611