Distortion correction of reconstructed three-dimensional image in an integral imaging system combined with a single imaging lens

被引:5
|
作者
Ser, Jang-Il [1 ]
Cha, Sungdo [1 ]
Shin, Seung-Ho [1 ]
机构
[1] Kangwon Natl Univ, Dept Phys, Chunchon 200701, South Korea
关键词
DEPTH; PROJECTION; DISPLAY;
D O I
10.1364/AO.48.003108
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The integral imaging (II) system combined with a single imaging lens has provided many advantages to improve system performance and to extend its application area. When a single imaging lens forms an image, a depth and size distortion is a necessary result of imaging by lens law. Therefore the II system, employing a single imaging lens, is also accompanied with similar distortions. In the 11 system, the depth and size of the reconstructed image can be adjusted by parallax image array (PIA) scaling. With regard to these scaling effects, the distortion correction method in the II system combined with a single imaging lens has been investigated. The differential transfer function (DTF) is defined and theoretically derived for mathematical analysis of the distortion. By using DTF, the PIA scaling conditions for the distortion correction in the II system combined with the single imaging lens is obtained. Experimental results are presented and discussed in detail. (C) 2009 Optical Society of America
引用
收藏
页码:3108 / 3119
页数:12
相关论文
共 50 条
  • [31] Three-dimensional polarimetric computational integral imaging
    Xiao, Xiao
    Javidi, Bahram
    Saavedra, Genaro
    Eismann, Michael
    Martinez-Corral, Manuel
    OPTICS EXPRESS, 2012, 20 (14): : 15481 - 15488
  • [32] Integral three-dimensional imaging with digital reconstruction
    Arimoto, H
    Javidi, B
    OPTICS LETTERS, 2001, 26 (03) : 157 - 159
  • [33] Three-dimensional integral imaging with flexible sensing
    Wang, Jingang
    Xiao, Xiao
    Javidi, Bahram
    OPTICS LETTERS, 2014, 39 (24) : 6855 - 6858
  • [34] Compact integral three-dimensional imaging device
    Arai, J.
    Yamashita, T.
    Hiura, H.
    Miura, M.
    Funatsu, R.
    Nakamura, T.
    Nakasu, E.
    THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2015, 2015, 9495
  • [35] Three-dimensional photon counting integral imaging using moving array lens technique
    Cho, Myungjin
    Javidi, Bahram
    OPTICS LETTERS, 2012, 37 (09) : 1487 - 1489
  • [36] Computational Reconstruction of Three-Dimensional Integral Imaging by Rearrangement of Elemental Image Pixels
    Cho, Myungjin
    Javidi, Bahram
    JOURNAL OF DISPLAY TECHNOLOGY, 2009, 5 (1-3): : 61 - 65
  • [37] Study on the stereo depth of integral imaging three-dimensional display system
    Wang, Fang
    Li, Da
    Zhao, Xing
    Yang, Yong
    Fang, Zhiliang
    Yuan, Xiaocong
    Zhongguo Jiguang/Chinese Journal of Lasers, 2011, 38 (SUPPL. 1): : 109002 - 1
  • [38] Three-Dimensional Image Transmission of Integral Imaging through Wireless MIMO Channel
    Lim, Seung-Chan
    Cho, Myungjin
    SENSORS, 2023, 23 (13)
  • [39] Three-dimensional polarimetric imaging based on integral-imaging techniques
    Xiao, Xiao
    Javidi, Bahram
    THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2013, 2013, 8738
  • [40] Three-dimensional integral imaging display system via off-axially distributed image sensing
    Piao, Yongri
    Qu, Hongjia
    Zhang, Miao
    Cho, Myungjin
    OPTICS AND LASERS IN ENGINEERING, 2016, 85 : 18 - 23