Distortion correction of reconstructed three-dimensional image in an integral imaging system combined with a single imaging lens

被引:5
|
作者
Ser, Jang-Il [1 ]
Cha, Sungdo [1 ]
Shin, Seung-Ho [1 ]
机构
[1] Kangwon Natl Univ, Dept Phys, Chunchon 200701, South Korea
关键词
DEPTH; PROJECTION; DISPLAY;
D O I
10.1364/AO.48.003108
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The integral imaging (II) system combined with a single imaging lens has provided many advantages to improve system performance and to extend its application area. When a single imaging lens forms an image, a depth and size distortion is a necessary result of imaging by lens law. Therefore the II system, employing a single imaging lens, is also accompanied with similar distortions. In the 11 system, the depth and size of the reconstructed image can be adjusted by parallax image array (PIA) scaling. With regard to these scaling effects, the distortion correction method in the II system combined with a single imaging lens has been investigated. The differential transfer function (DTF) is defined and theoretically derived for mathematical analysis of the distortion. By using DTF, the PIA scaling conditions for the distortion correction in the II system combined with the single imaging lens is obtained. Experimental results are presented and discussed in detail. (C) 2009 Optical Society of America
引用
收藏
页码:3108 / 3119
页数:12
相关论文
共 50 条
  • [21] Three-dimensional integral imaging system using volume holography
    Shin, SH
    Javidi, B
    LEOS 2001: 14TH ANNUAL MEETING OF THE IEEE LASERS & ELECTRO-OPTICS SOCIETY, VOLS 1 AND 2, PROCEEDINGS, 2001, : 493 - 494
  • [22] Three-dimensional image sensing, visualization, and processing using integral imaging
    Stern, A
    Javidi, B
    PROCEEDINGS OF THE IEEE, 2006, 94 (03) : 591 - 607
  • [23] ATTENUATION CORRECTION FOR THREE-DIMENSIONAL IMAGING
    GULLBERG, GT
    BUDINGER, TF
    JOURNAL OF NUCLEAR MEDICINE, 1974, 15 (06) : 497 - 498
  • [24] Computational Depth Conversion of Reconstructed Three-Dimensional Object Images in Curving-Effective Integral Imaging System
    Piao, Yongri
    Shin, Dong-Hak
    Kim, Eun-Soo
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (02)
  • [25] Functional three-dimensional imaging based on integral imaging technique
    Park, Jae-Hyeung
    THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2012, 2012, 8384
  • [26] Elemental image compatibility between parallax generation and Integral Imaging system for three-dimensional display
    Il Ser, Jang
    Kang, Keun Ho
    Seo, Kwang Bum
    Cha, Sungdo
    Shin, Seung-Ho
    IMID/IDMC 2006: THE 6TH INTERNATIONAL MEETING ON INFORMATION DISPLAY/THE 5TH INTERNATIONAL DISPLAY MANUFACTURING CONFERENCE, DIGEST OF TECHNICAL PAPERS, 2006, : 1569 - 1574
  • [27] Coordinate transformation of three-dimensional image in integral imaging system illuminated by a point light source
    Lou, Yimin
    Hu, Juanmei
    OPTIK, 2021, 226
  • [28] Wide-viewing-angle integral three-dimensional imaging system by curving a screen and a lens array
    Kim, Y
    Park, JH
    Min, SW
    Jung, S
    Choi, HJ
    Lee, B
    APPLIED OPTICS, 2005, 44 (04) : 546 - 552
  • [29] Asymmetrical Three-Dimensional Conformal Imaging Lens
    Gong, Desen
    Ge, Yixiao
    Xiao, Wen
    Chen, Huanyang
    PHOTONICS, 2024, 11 (06)
  • [30] Three-dimensional synthetic aperture integral imaging
    Jang, JS
    Javidi, B
    OPTICS LETTERS, 2002, 27 (13) : 1144 - 1146