Comparison of chevron and suspended-zipper braced steel frames

被引:18
|
作者
Ozcelik, Yigit [1 ]
Saritas, Afsin [2 ]
Clayton, Patricia M. [1 ]
机构
[1] Univ Texas Austin, Dept Civil Architectural & Environm Engn, Austin, TX 78712 USA
[2] Middle E Tech Univ, Dept Civil Engn, TR-06800 Ankara, Turkey
关键词
Steel structures; Concentrically braced frames; Chevron braced frames; Suspended-zipper braced frames; Nonlinear static analysis; Nonlinear time-history analysis; RESPONSE MODIFICATION FACTORS; SEISMIC PERFORMANCE; BEAM; DESIGN; MODEL;
D O I
10.1016/j.jcsr.2015.12.019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Suspended-zipper braced frame is a modified configuration of chevron braced frame in which zipper columns are added between story beams and a hat truss is attached between top two stories in order to redistribute the unbalanced vertical forces emerging following the brace buckling to avoid the use of deep beams. In this study, three- and nine-story chevron and suspended-zipper braced frames are analyzed to compare their seismic performances. The beams, columns, braces and zipper columns are modeled using nonlinear force-formulation frame elements and nonlinear geometric effects are included by utilizing corotational transformation. Nonlinear static analyses are performed until reaching a roof drift ratio of 3% and a set of twenty ground motion records scaled to match a 10% probability of exceedance in 50 years is used for nonlinear time-history analysis. The results appear to indicate that the lateral load capacity and drift demands for both low-rise chevron and suspended zipper braced frames are very similar; however, the mid-rise chevron braced frame has a better performance compared to the mid-rise suspended-zipper braced frame. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:169 / 175
页数:7
相关论文
共 50 条
  • [1] Comparison of seismic behavior of chevron and suspended-zipper braced frames under near-fault ground motion
    Emami F.
    Bakhtiari-Moghadam M.
    Asian Journal of Civil Engineering, 2021, 22 (6) : 1131 - 1141
  • [2] Evaluation of the seismic performance of suspended zipper column concentrically braced steel frames
    Wijesundara, K. K.
    Nascimbene, R.
    Rassati, Gian A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 150 : 452 - 461
  • [3] Response modification factor of suspended zipper braced frames
    Abdollahzadeh, Gholamreza
    Abbasi, Mehdi
    STEEL AND COMPOSITE STRUCTURES, 2015, 18 (01): : 165 - 185
  • [4] Design and seismic response of modified suspended zipper braced frames
    Yu, Haifeng
    Guo, Yaran
    Zhang, Yan
    Wang, Xin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 120 : 8 - 24
  • [5] Seismic Assessment of Existing Steel Chevron Braced Frames
    Balazadeh-Minouei, Yasaman
    Koboevic, Sanda
    Tremblay, Robert
    JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (06)
  • [6] Seismic collapse safety assessment of suspended zipper-braced frames
    Taghizadeh, Mohammad Ali Mohammad
    Karamodin, Abbas
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2023,
  • [7] A design procedure for suspended zipper-braced frames in the framework of Eurocode 8
    Rossi, Pier Paolo
    Quaceci, Giuseppe
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2017, 46 (12): : 1963 - 1985
  • [8] Tests of chevron panel buckling-restrained braced steel frames
    Ding, Yukun
    Zheng, Rui
    Zhang, Wenyuan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 143 : 233 - 249
  • [9] Cyclic testing of chevron braced steel frames with IPE shear panels
    Zahrai, Seyed Mehdi
    STEEL AND COMPOSITE STRUCTURES, 2015, 19 (05): : 1167 - 1184
  • [10] Seismic performance of steel chevron braced frames designed according to Japanese practice
    Seki, Akiri
    Inoue, Keisuke
    Okazaki, Taichiro
    Hashioka, Shogo
    Asada, Hayato
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 189