Comparison of chevron and suspended-zipper braced steel frames

被引:18
|
作者
Ozcelik, Yigit [1 ]
Saritas, Afsin [2 ]
Clayton, Patricia M. [1 ]
机构
[1] Univ Texas Austin, Dept Civil Architectural & Environm Engn, Austin, TX 78712 USA
[2] Middle E Tech Univ, Dept Civil Engn, TR-06800 Ankara, Turkey
关键词
Steel structures; Concentrically braced frames; Chevron braced frames; Suspended-zipper braced frames; Nonlinear static analysis; Nonlinear time-history analysis; RESPONSE MODIFICATION FACTORS; SEISMIC PERFORMANCE; BEAM; DESIGN; MODEL;
D O I
10.1016/j.jcsr.2015.12.019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Suspended-zipper braced frame is a modified configuration of chevron braced frame in which zipper columns are added between story beams and a hat truss is attached between top two stories in order to redistribute the unbalanced vertical forces emerging following the brace buckling to avoid the use of deep beams. In this study, three- and nine-story chevron and suspended-zipper braced frames are analyzed to compare their seismic performances. The beams, columns, braces and zipper columns are modeled using nonlinear force-formulation frame elements and nonlinear geometric effects are included by utilizing corotational transformation. Nonlinear static analyses are performed until reaching a roof drift ratio of 3% and a set of twenty ground motion records scaled to match a 10% probability of exceedance in 50 years is used for nonlinear time-history analysis. The results appear to indicate that the lateral load capacity and drift demands for both low-rise chevron and suspended zipper braced frames are very similar; however, the mid-rise chevron braced frame has a better performance compared to the mid-rise suspended-zipper braced frame. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:169 / 175
页数:7
相关论文
共 50 条
  • [21] An Alternative Approach for the Design of Chevron-Braced Frames
    Barbagallo, Francesca
    Bosco, Melina
    Caragliano, Marco
    Marino, Edoardo M.
    Rossi, Pier Paolo
    APPLIED SCIENCES-BASEL, 2021, 11 (22):
  • [22] Ductility reduction factor for zipper-braced frames
    Amiri, J. Vaseghi
    Amiri, M. Esmaeilnia
    Ganjavi, B.
    EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2018, 22 (11) : 1341 - 1363
  • [23] Response modification factors of chevron-braced frames
    Kim, JK
    Choi, H
    ENGINEERING STRUCTURES, 2005, 27 (02) : 285 - 300
  • [24] Seismic performance of cable zipper-braced frames
    Razavi, M.
    Sheidaii, M. R.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 74 : 49 - 57
  • [25] Pushover response of a braced frame with suspended zipper struts
    Yang, Chuang-Sheng
    Leon, Roberto T.
    DesRoches, Reginald
    JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (10) : 1619 - 1626
  • [26] Damage-based optimal design of friction dampers in multistory chevron braced steel frames
    Taiyari, Farshad
    Mazzolani, Federico M.
    Bagheri, Saman
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 119 : 11 - 20
  • [27] Damage Concentration and Column Flexural Demands in Steel Chevron Braced Frames Designed to Canadian Provisions
    Mahmoudi, Bardia
    Imanpour, Ali
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, VOL 2, STESSA 2024, 2024, 520 : 733 - 746
  • [28] Cyclic Performance of an Elliptical-Shaped Damper with Shear Diaphragms in Chevron Braced Steel Frames
    Zahrai, Seyed Mehdi
    Mortezagholi, Mohamad Hosein
    JOURNAL OF EARTHQUAKE ENGINEERING, 2018, 22 (07) : 1209 - 1232
  • [29] Design and seismic response of tall chevron panel buckling-restrained braced steel frames
    Ding, Yukun
    Zhang, Yaochun
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2013, 22 (14): : 1083 - 1104
  • [30] Collapse Performance of Low-Ductility Chevron Braced Steel Frames in Moderate Seismic Regions
    Hines, Eric M.
    Appel, Mary E.
    Cheever, Peter J.
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 2009, 46 (03): : 149 - 180