Smart watch accelerometry for analysis and diagnosis of tremor

被引:112
|
作者
Wile, Daryl J. [1 ]
Ranawaya, Ranjit [1 ]
Kiss, Zelma H. T. [1 ]
机构
[1] Univ Calgary, Dept Clin Neurosci, Hotchkiss Brain Inst, Calgary, AB T2N 2T9, Canada
基金
加拿大健康研究院;
关键词
Tremor; Parkinson's disease; Essential tremor; Accelerometry; PARKINSONS-DISEASE;
D O I
10.1016/j.jneumeth.2014.04.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Distinguishing the postural re-emergent tremor of Parkinson disease from essential tremor can be difficult clinically. Use of accelerometry to aid diagnosis is limited to laboratory settings. We sought to record and differentiate these tremors using a smart watch device in an outpatient clinic. New method: 41 patients were enrolled. Recordings were made with a smart watch device on the predominantly affected hand (all patients), and simultaneously with an analog accelerometer (10 patients) with hands at rest and outstretched. Tremor peak frequency, peak power, and power of the first four harmonics was calculated and compared between the two devices. Mean power at the first four harmonics was calculated and used to classify tremor as parkinsonian or essential. Test characteristics were calculated to compare the device and clinical diagnoses. Results: Mean harmonic peak power was both highly sensitive and specific for distinction of Parkinson disease postural tremor from essential tremor with an optimal threshold for our sample (sensitivity 90.9%, 95% CI 58.7-99.8%; specificity 100%, 95% CI 76.8-100%; Cohen's kappa = 0.91, SE = 0.08). Comparison with existing methods: The smart watch and analog devices had nearly perfect concordance of peak frequency and proportional harmonic power. The smart watch recordings in clinic took 3-6 min. Conclusions: A smart watch device can provide accurate and diagnostically relevant information about postural tremor. Its portability and ease of use could help translate such techniques into routine clinic use or to the community. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 50 条
  • [41] Watch out! Allergic contact dermatitis to acrylates in a smart watch
    Davies, Anna
    Stone, Natalie
    BRITISH JOURNAL OF DERMATOLOGY, 2024, 191 : I89 - I89
  • [42] ACCELEROMETRY - A TECHNIQUE FOR NONINVASIVE DIAGNOSIS OF DYSPHAGIA
    CANILANG, EP
    REDDY, NP
    CANDADAI, RS
    JOSHI, AM
    CASTERLINE, JL
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1988, 69 (09): : 743 - 743
  • [43] Smart Watch for Smart Health Monitoring: A Literature Review
    Jat, Avnish Singh
    Gronli, Tor-Morten
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING, PT I, 2022, : 256 - 268
  • [44] Watch what you wear: preliminary forensic analysis of smart watches
    Baggili, Ibrahim
    Oduru, Jeff
    Anthony, Kyle
    Breitinger, Frank
    McGee, Glenn
    PROCEEDINGS 10TH INTERNATIONAL CONFERENCE ON AVAILABILITY, RELIABILITY AND SECURITY ARES 2015, 2015, : 303 - 311
  • [45] Smart Watch for Smart Health Monitoring: A Literature Review
    Jat, Avnish Singh
    Grønli, Tor-Morten
    Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics), 2022, 13346 LNBI : 256 - 268
  • [46] ACCELEROMETRY IN GAIT ANALYSIS
    MORRIS, JRW
    BRITISH JOURNAL OF SURGERY, 1972, 59 (11) : 899 - &
  • [47] Correlation between clinical tests and accelerometry in the assessment of cerebellar tremor in multiple sclerosis
    Seidel, S.
    Samal, D.
    Zezula, J.
    Vass, K.
    Auff, E.
    MOVEMENT DISORDERS, 2007, 22 : S15 - S15
  • [48] Accelerometry in motion analysis
    Senanayake, S. M. N. A.
    Yuen, A. W. W.
    Wilson, B. D.
    IMPACT OF TECHNOLOGY ON SPORTS II, 2008, : 479 - 484
  • [49] Differentiation and Diagnosis of Tremor
    Crawford, Paul
    Zimmerman, Ethan E.
    AMERICAN FAMILY PHYSICIAN, 2011, 83 (06) : 697 - 702
  • [50] QUANTITATIVE ASSESSMENT OF PARKINSONIAN AND ESSENTIAL TREMOR - CLINICAL-APPLICATION OF TRIAXIAL ACCELEROMETRY
    JANKOVIC, J
    FROST, JD
    NEUROLOGY, 1980, 30 (04) : 393 - 393