Smart watch accelerometry for analysis and diagnosis of tremor

被引:112
|
作者
Wile, Daryl J. [1 ]
Ranawaya, Ranjit [1 ]
Kiss, Zelma H. T. [1 ]
机构
[1] Univ Calgary, Dept Clin Neurosci, Hotchkiss Brain Inst, Calgary, AB T2N 2T9, Canada
基金
加拿大健康研究院;
关键词
Tremor; Parkinson's disease; Essential tremor; Accelerometry; PARKINSONS-DISEASE;
D O I
10.1016/j.jneumeth.2014.04.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Distinguishing the postural re-emergent tremor of Parkinson disease from essential tremor can be difficult clinically. Use of accelerometry to aid diagnosis is limited to laboratory settings. We sought to record and differentiate these tremors using a smart watch device in an outpatient clinic. New method: 41 patients were enrolled. Recordings were made with a smart watch device on the predominantly affected hand (all patients), and simultaneously with an analog accelerometer (10 patients) with hands at rest and outstretched. Tremor peak frequency, peak power, and power of the first four harmonics was calculated and compared between the two devices. Mean power at the first four harmonics was calculated and used to classify tremor as parkinsonian or essential. Test characteristics were calculated to compare the device and clinical diagnoses. Results: Mean harmonic peak power was both highly sensitive and specific for distinction of Parkinson disease postural tremor from essential tremor with an optimal threshold for our sample (sensitivity 90.9%, 95% CI 58.7-99.8%; specificity 100%, 95% CI 76.8-100%; Cohen's kappa = 0.91, SE = 0.08). Comparison with existing methods: The smart watch and analog devices had nearly perfect concordance of peak frequency and proportional harmonic power. The smart watch recordings in clinic took 3-6 min. Conclusions: A smart watch device can provide accurate and diagnostically relevant information about postural tremor. Its portability and ease of use could help translate such techniques into routine clinic use or to the community. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 50 条
  • [31] Assessment of fluctuating tremor using miniaturised and prolonged ambulatory accelerometry
    Richardson, H.
    Grosset, K. A.
    Leuthold, H.
    Grosset, D. G.
    EUROPEAN JOURNAL OF NEUROLOGY, 2006, 13 : 82 - 82
  • [32] Head Accelerometry May be Useful as a Test of Psychogenic Head Tremor
    Ramos, Vesper Fe Marie Llaneza
    Hallett, Mark
    MOVEMENT DISORDERS CLINICAL PRACTICE, 2014, 1 (04): : 395 - 396
  • [33] Clinical analysis in familial cortical myoclonic tremor allows differential diagnosis with essential tremor
    Bourdain, Fredric
    Apartis, Emmanuelle
    Trocello, Jean-Marc
    Vidal, Jean-Sebastien
    Masnou, Pascal
    Vercueil, Laurent
    Vidailhet, Marie
    MOVEMENT DISORDERS, 2006, 21 (05) : 599 - 608
  • [34] Misdiagnosis From a Smart Watch
    Desai, Yaanik B.
    Badhwar, Nitish
    CIRCULATION, 2024, 150 (04) : 340 - 342
  • [35] LOBBY WATCH Media Smart
    Cookson, Richard
    BRITISH MEDICAL JOURNAL, 2011, 343
  • [36] Text Input on a Smart Watch
    Komninos, Andreas
    Dunlop, Mark
    IEEE PERVASIVE COMPUTING, 2014, 13 (04) : 50 - 58
  • [37] Clinical analysis in familial myoclonic cortical tremor allows differential diagnosis with essential tremor
    Bourdain, F
    Apartis, E
    Trocello, JM
    Vidal, JS
    Vidailhet, M
    MOVEMENT DISORDERS, 2004, 19 : S450 - S450
  • [38] Microstrip Antennas for Smart Watch
    Lin, Shun-Yun
    Lin, Yuan-Chih
    Peng, Jhih-Jian
    Tuan, Yan-Yu
    2016 IEEE 5TH ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION (APCAP 2016), 2016, : 109 - 110
  • [39] Smart Watch Detects Seizures
    Voelker, Rebecca
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2018, 319 (11): : 1086 - 1086
  • [40] POSTER: Watch Out Your Smart Watch When Paired
    Lee, Youngjoo
    Yang, WonSeok
    Kwon, Taekyoung
    CCS'17: PROCEEDINGS OF THE 2017 ACM SIGSAC CONFERENCE ON COMPUTER AND COMMUNICATIONS SECURITY, 2017, : 2527 - 2529