Analysis and Control of the Accuracy and Convergence of the ML-EM Iteration

被引:1
|
作者
Magdics, Milan [1 ,2 ,3 ]
Szirmay-Kalos, Laszlo [1 ]
Toth, Balazs [1 ]
Penzov, Anton
机构
[1] Tech Univ Budapest, Budapest, Hungary
[2] Univ Girona, Girona, Spain
[3] Tech Univ Budapest, Budapest, Hungary
关键词
D O I
10.1007/978-3-662-43880-0_18
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
In inverse problems like tomography reconstruction we need to solve an over-determined linear system corrupted with noise. The ML-EM algorithm finds the solution for Poisson noise as the fixed point of iterating a forward projection and a non-linear back projection. In tomography we have several hundred million equations and unknowns. The elements of the huge matrix are high-dimensional integrals, which cannot be stored, but must be re-computed with Monte Carlo (MC) quadrature when needed. In this paper we address the problems of how the quadrature error affects the accuracy of the reconstruction, whether it is possible to modify the back projection to speed up convergence without compromising the accuracy, and whether we should always take the same MC estimate or modify it in every projection.
引用
收藏
页码:170 / 177
页数:8
相关论文
共 50 条
  • [31] Application of the ML-EM algorithm in the suppression of Compton background of gamma-ray spectroscopy system
    Hoang, Sy Minh Tuan
    Sun, Gwang Min
    Baek, Hani
    Kim, Jiseok
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (03) : 2137 - 2146
  • [32] ML-EM based dual tracer PET image reconstruction with inclusion of prompt gamma attenuation
    Pfaehler, Elisabeth
    Niekaemper, Debora
    Scheins, Juergen
    Shah, N. Jon
    Lerche, Christoph W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (01):
  • [33] Temperature distribution measurement based on ML-EM method using enclosed acoustic CT system
    1600, International Frequency Sensor Association, 46 Thorny Vineway, Toronto, ON M2J 4J2, Canada (150):
  • [34] Limited-angular-view ML-EM pinhole SPECT for breast tumor detection.
    Li, J
    Scarfone, C
    Jaszczak, RJ
    Wang, H
    Coleman, RE
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 971 - 971
  • [35] NOISE PROPERTIES OF FILTERED-BACKPROJECTION AND ML-EM RECONSTRUCTED EMISSION TOMOGRAPHIC-IMAGES
    WILSON, DW
    TSUI, BMW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 1198 - 1203
  • [36] Semi-analytical response function for ML-EM deconvolution of NaI detector energy spectra
    Engdahl, John C.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1346 - 1350
  • [37] A hybrid ML-EM algorithm for calculation of maximum likelihood estimates in semiparametric shared frailty models
    Vu, HTV
    Knuiman, MW
    COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2002, 40 (01) : 173 - 187
  • [38] A tailored ML-EM algorithm for reconstruction of truncated projection data using few view angles
    Mao, Yanfei
    Zeng, Gengsheng L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (12): : N157 - N169
  • [39] Application of the ML-EM algorithm in the suppression of Compton background of gamma-ray spectroscopy system
    Sy Minh Tuan Hoang
    Gwang Min Sun
    Hani Baek
    Jiseok Kim
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 2137 - 2146
  • [40] ML-EM Reconstruction Model including Total Variation for Low Dose PET High Resolution Data
    Chavez-Rivera, Lucia B.
    Ortega-Maynez, Leticia
    Mejia, Jose
    Mederos, Boris
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,