Analysis and Control of the Accuracy and Convergence of the ML-EM Iteration

被引:1
|
作者
Magdics, Milan [1 ,2 ,3 ]
Szirmay-Kalos, Laszlo [1 ]
Toth, Balazs [1 ]
Penzov, Anton
机构
[1] Tech Univ Budapest, Budapest, Hungary
[2] Univ Girona, Girona, Spain
[3] Tech Univ Budapest, Budapest, Hungary
关键词
D O I
10.1007/978-3-662-43880-0_18
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
In inverse problems like tomography reconstruction we need to solve an over-determined linear system corrupted with noise. The ML-EM algorithm finds the solution for Poisson noise as the fixed point of iterating a forward projection and a non-linear back projection. In tomography we have several hundred million equations and unknowns. The elements of the huge matrix are high-dimensional integrals, which cannot be stored, but must be re-computed with Monte Carlo (MC) quadrature when needed. In this paper we address the problems of how the quadrature error affects the accuracy of the reconstruction, whether it is possible to modify the back projection to speed up convergence without compromising the accuracy, and whether we should always take the same MC estimate or modify it in every projection.
引用
收藏
页码:170 / 177
页数:8
相关论文
共 50 条
  • [21] Time of Flight Ultrasonic CT Based on ML-EM for Wooden Pillars
    Fan, Honghui
    Yanagida, Hirotaka
    Guo, Shuqing
    Takahashi, Tatsuhisa
    Tamura, Yasutaka
    Adachi, Kazunari
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1495 - +
  • [22] Statistical Model and ML-EM Algorithm for Emission Tomography with Known Movement
    Camille Pouchol
    Olivier Verdier
    Journal of Mathematical Imaging and Vision, 2021, 63 : 650 - 663
  • [23] Statistical iterative pattern generation in volumetric additive manufacturing based on ML-EM
    Chen, Tianhang
    Li, Haifeng
    Liu, Xu
    OPTICS COMMUNICATIONS, 2023, 537
  • [24] ML-EM PET Reconstruction Method with On-the-fly Monte Carlo Projections
    Wirth, A. D.
    Kari, B.
    Cserkaszky, A.
    Legrady, D.
    Domonkos, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S204 - S205
  • [25] Web-based parallel ML-EM reconstruction for SPECT on SMP clusters
    Backfrieder, W
    Benkner, S
    Engelbrecht, G
    METMBS'01: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MATHEMATICS AND ENGINEERING TECHNIQUES IN MEDICINE AND BIOLOGICAL SCIENCES, 2001, : 491 - 497
  • [26] Cross-validation stopping rule for ML-EM reconstruction of dynamic PET series: Effect on image quality and quantitative accuracy
    Selivanov, VV
    Lapointe, D
    Bentourkia, M
    Lecomte, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 883 - 889
  • [27] Cross-validation stopping rule for ML-EM reconstruction of dynamic PET series: Effect on image quality and quantitative accuracy
    Selivanov, V
    Lapointe, D
    Bentourkia, M
    Lecomte, R
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1433 - 1437
  • [28] Dynamic List-Mode Reconstruction of PET Data based on the ML-EM Algorithm
    Gundlich, Brigitte
    Musmann, Patrick
    Weber, Simone
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2791 - 2795
  • [29] Hybrid of ML-EM and MART algorithms for X-ray CT image reconstruction
    Kasai, R.
    Yamaguchi, Y.
    Kojima, T.
    Yoshinaga, T.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 26 - 26
  • [30] COMPARISON BETWEEN ML-EM AND WLS-CG ALGORITHMS FOR SPECT IMAGE-RECONSTRUCTION
    TSUI, BMW
    ZHAO, XD
    FREY, EC
    GULLBERG, GT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (06) : 1766 - 1772