Magnetic resonance image segmentation using semi-automated software for quantification of knee articular cartilage-initial evaluation of a technique for paired scans

被引:26
|
作者
Brem, M. H. [1 ,7 ]
Lang, P. K. [1 ]
Neumann, G. [1 ]
Schlechtweg, P. M. [1 ]
Schneider, E. [2 ,3 ]
Jackson, R. [4 ]
Yu, J. [4 ]
Eaton, C. B. [5 ,6 ]
Hennig, F. F. [7 ]
Yoshioka, H. [1 ]
Pappas, G. [1 ]
Duryea, J. [1 ]
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] SciTrials LLC, Rocky River, OH USA
[3] Cleveland Clin, Imaging Inst, Cleveland, OH 44106 USA
[4] Ohio State Univ, Dept Endocrinol, Columbus, OH 43210 USA
[5] Brown Univ, Warren Alpert Med Sch, Providence, RI 02912 USA
[6] Brown Univ, Mem Hosp Rhode Isl, Ctr Primary Care & Prevent, Providence, RI 02912 USA
[7] Univ Erlangen Nurnberg, Dept Surg, Div Orthopaed & Trauma Surg, Erlangen, Germany
关键词
Osteoarthritis; Knee; Cartilage; MRI; Segmentation; OSTEOARTHRITIS; REPRODUCIBILITY; PRECISION; THICKNESS; VOLUME; BONE; ASSOCIATION; RELIABILITY; MORPHOLOGY; ACCURACY;
D O I
10.1007/s00256-009-0658-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Software-based image analysis is important for studies of cartilage changes in knee osteoarthritis (OA). This study describes an evaluation of a semi-automated cartilage segmentation software tool capable of quantifying paired images for potential use in longitudinal studies of knee OA. We describe the methodology behind the analysis and demonstrate its use by determination of test-retest analysis precision of duplicate knee magnetic resonance imaging (MRI) data sets. Test-retest knee MR images of 12 subjects with a range of knee health were evaluated from the Osteoarthritis Initiative (OAI) pilot MR study. Each subject was removed from the magnet between the two scans. The 3D DESS (sagittal, 0.456 mm x 0.365 mm, 0.7 mm slice thickness, TR 16.5 ms, TE 4.7 ms) images were obtained on a 3-T Siemens Trio MR system with a USA Instruments quadrature transmit-receive extremity coil. Segmentation of one 3D-image series was first performed and then the corresponding retest series was segmented by viewing both image series concurrently in two adjacent windows. After manual registration of the series, the first segmentation cartilage outline served as an initial estimate for the second segmentation. We evaluated morphometric measures of the bone and cartilage surface area (tAB and AC), cartilage volume (VC), and mean thickness (ThC.me) for medial/lateral tibia (MT/LT), total femur (F) and patella (P). Test-retest reproducibility was assessed using the root-mean square coefficient of variation (RMS CV%). For the paired analyses, RMS CV % ranged from 0.9% to 1.2% for VC, from 0.3% to 0.7% for AC, from 0.6% to 2.7% for tAB and 0.8% to 1.5% for ThC.me. Paired image analysis improved the measurement precision of cartilage segmentation. Our results are in agreement with other publications supporting the use of paired analysis for longitudinal studies of knee OA.
引用
收藏
页码:505 / 511
页数:7
相关论文
共 27 条
  • [21] Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique
    Arai, Hideo
    Kawakubo, Masateru
    Abe, Ko
    Hatashima, Hikaru
    Sanui, Kenichi
    Nishimura, Hiroshi
    Kadokami, Toshiaki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (01): : 111 - 119
  • [22] A fully automated hybrid methodology using Cuckoo-based fuzzy clustering technique for magnetic resonance brain image segmentation
    Alagarsamy, Saravanan
    Kamatchi, Kartheeban
    Govindaraj, Vishnuvarthanan
    Thiyagarajan, Arunprasath
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2017, 27 (04) : 317 - 332
  • [23] In vivo articular cartilage contact kinematics of the knee - An investigation using dual-orthogonal fluoroscopy and magnetic resonance image-based computer models
    Li, GA
    DeFrate, LE
    Park, SE
    Gill, TJ
    Rubash, HE
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (01): : 102 - 107
  • [24] Comparison of semi-automated scar quantification techniques using high-resolution, 3-dimensional late-gadolinium-enhancement magnetic resonance imaging
    Rajchl, Martin
    Stirrat, John
    Goubran, Maged
    Yu, Jeff
    Scholl, David
    Peters, Terry M.
    White, James A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (02): : 349 - 357
  • [25] Comparison of semi-automated scar quantification techniques using high-resolution, 3-dimensional late-gadolinium-enhancement magnetic resonance imaging
    Martin Rajchl
    John Stirrat
    Maged Goubran
    Jeff Yu
    David Scholl
    Terry M. Peters
    James A. White
    The International Journal of Cardiovascular Imaging, 2015, 31 : 349 - 357
  • [26] PRE-OPERATIVE EVALUATION OF PATIENTS UNDERGOING KNEE ARTICULAR CARTILAGE REPAIR: MRI 3D THICKNESS MAPS DERIVED FROM A VALIDATED, AUTOMATED SEGMENTATION PLATFORM - INITIAL RESULTS
    Farber, J. M.
    Tamez-Pena, J.
    Totterman, S.
    Larkin, J.
    Holladay, B.
    Heis, F.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 : S202 - S202
  • [27] Assessing joint destruction in the knees of patients with rheumatoid arthritis by using a semi-automated software for magnetic resonance imaging: therapeutic effect of methotrexate plus etanercept compared with methotrexate monotherapy
    Oka, Hiroyuki
    Kadono, Yuho
    Ohashi, Satoru
    Yasui, Tetsuro
    Ono, Kumiko
    Matsudaira, Ko
    Nishino, Jinju
    Tanaka, Sakae
    MODERN RHEUMATOLOGY, 2018, 28 (02) : 235 - 241