Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique

被引:3
|
作者
Arai, Hideo [1 ]
Kawakubo, Masateru [2 ]
Abe, Ko [1 ]
Hatashima, Hikaru [3 ]
Sanui, Kenichi [1 ]
Nishimura, Hiroshi [1 ]
Kadokami, Toshiaki [1 ]
机构
[1] Fukuokaken Saiseikai Futsukaichi Hosp, Fukuoka, Japan
[2] Kyushu Univ, Fac Med Sci, Dept Hlth Sci, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
[3] Oita Prefectural Hosp, Oita, Japan
来源
关键词
Intramyocardial hemorrhage; Biomarker; Quantification; Semi-automated threshold method; Magnetic resonance imaging; Acute myocardial infarction; ELEVATION MYOCARDIAL-INFARCTION; LATE GADOLINIUM ENHANCEMENT; MICROVASCULAR OBSTRUCTION; ST-ELEVATION; MANAGEMENT; OUTCOMES; IMPACT; MRI;
D O I
10.1007/s10554-019-01697-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although intramyocardial hemorrhage (IMH) is a poor prognostic factor caused by ischemia reperfusion injury, little evidence is available regarding the association between IMH volume and biomarkers. In the present study, we measured IMH volume using three-dimensional (3D) T1-weighted magnetic resonance imaging (T1-MRI) and investigated its association with biomarkers. Moreover, the accuracy of semi-automatic measurement of IMH volume was validated. We retrospectively enrolled 33 consecutive patients (mean age 67 +/- 11 years) who underwent cardiac MRI after reperfusion therapy for acute myocardial infarction. IMH was observed in 4 patients (12.1%). Receiver operating characteristics (ROC) analysis of creatine kinase (CK) and CK-muscle/brain (CK-MB) tests for detecting IMH were performed. IMH volume measured using semi-automatic methods by a 2 standard deviation (SD) threshold was compared to manual measurements using the Spearman's correlation coefficient (rho) and Bland-Altman analyses. ROC analysis revealed optimal cutoff values of CK: 2460 IU/l and CK-MB: 231 IU/l (area under the curve: 0.95 and 0.91; sensitivity: 86% and 79%; specificity: 100% for both). IMH volume with the 2SD threshold correlated with that of the manual measurement [5.84 g (3.30 to 9.00) g vs. 8.07 g (5.37 to 9.33); rho: 0.85, p < 0.01; bias (limit of agreement): - 0.01 g (- 0.51 to 0.49); intraclass correlation coefficients 0.84 (0.75 to 0.90)]. Our findings could help identify the risk of IMH after reperfusion therapy with biomarkers. 3D T1-MRI can semi-automatically provide accurate IMH volume without being time-consuming.
引用
收藏
页码:111 / 119
页数:9
相关论文
共 38 条
  • [1] Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique
    Hideo Arai
    Masateru Kawakubo
    Ko Abe
    Hikaru Hatashima
    Kenichi Sanui
    Hiroshi Nishimura
    Toshiaki Kadokami
    The International Journal of Cardiovascular Imaging, 2020, 36 : 111 - 119
  • [2] MR imaging of the brachial plexus using a T1-weighted three-dimensional volume acquisition
    vanEs, HW
    Witkamp, TD
    Ramos, LMP
    Feldberg, MAM
    Nowicki, BH
    Haughton, VM
    INTERNATIONAL JOURNAL OF NEURORADIOLOGY, 1996, 2 (03): : 264 - 273
  • [3] Three-dimensional T1-weighted sequence for fetal intracranial hemorrhage: A step forward in the reconstruction and quantification of brain lesions
    Castro, Pedro Teixeira
    Matos, Ana Paula Pinho
    Werner, Heron
    Ribeiro, Gerson
    Lopes, Jorge
    da Silva, Marcio Bernardes
    Araujo Junior, Edward
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 143
  • [4] Automated histogram-based brain segmentation in T1-weighted three-dimensional magnetic resonance head images
    Shan, ZY
    Yue, GH
    Liu, JZ
    NEUROIMAGE, 2002, 17 (03) : 1587 - 1598
  • [5] Assessment of the Impact of Turbo Factor on Image Quality and Tissue Volumetrics in Brain Magnetic Resonance Imaging Using the Three-Dimensional T1-Weighted (3D T1W) Sequence
    Manson, Eric Naab
    Inkoom, Stephen
    Mumuni, Abdul Nashirudeen
    Shirazu, Issahaku
    Awua, Adolf Kofi
    Positano, Vincenzo
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2023, 2023
  • [6] Heavy T1-weighted three-dimensional magnetic resonance imaging has a potential to visualize unstable carotid atheroma
    Yamada, N
    Otsubo, R
    Higashi, M
    Tanaka, R
    Nagano, K
    Sakuma, T
    Minematsu, K
    Naritomi, H
    Naito, H
    STROKE, 2004, 35 (01) : 262 - 262
  • [7] Brain Extraction in Multiple T1-weighted Magnetic Resonance Imaging slices using Digital Image Processing techniques
    Duarte, Kaue T. N.
    Moura, Marinara A. N.
    Martins, Paulo S.
    de Carvalho, Marco A. G.
    IEEE LATIN AMERICA TRANSACTIONS, 2022, 20 (05) : 831 - 838
  • [8] A pilot study of compositional analysis of the breast and estimation of breast mammographic density using three-dimensional T1-weighted magnetic resonance imaging
    Khazen, Michael
    Warren, Ruth M. L.
    Boggis, Caroline R. M.
    Bryant, Emilie C.
    Reed, Sadie
    Warsi, Iqbal
    Pointon, Linda J.
    Kwan-Lim, Gek E.
    Thompson, Deborah
    Eeles, Ros
    Easton, Doug
    Evans, D. Gareth
    Leach, Martin O.
    CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2008, 17 (09) : 2268 - 2274
  • [9] Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity
    Jeong Hee Yoon
    Jeong Min Lee
    Eun Sun Lee
    Jeehyun Baek
    Sangwoo Lee
    Yuji Iwadate
    Joon Koo Han
    Byung Ihn Choi
    Abdominal Imaging, 2015, 40 : 278 - 288
  • [10] Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity
    Yoon, Jeong Hee
    Lee, Jeong Min
    Lee, Eun Sun
    Baek, Jeehyun
    Lee, Sangwoo
    Iwadate, Yuji
    Han, Joon Koo
    Choi, Byung Ihn
    ABDOMINAL IMAGING, 2015, 40 (02): : 278 - 288