Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique

被引:3
|
作者
Arai, Hideo [1 ]
Kawakubo, Masateru [2 ]
Abe, Ko [1 ]
Hatashima, Hikaru [3 ]
Sanui, Kenichi [1 ]
Nishimura, Hiroshi [1 ]
Kadokami, Toshiaki [1 ]
机构
[1] Fukuokaken Saiseikai Futsukaichi Hosp, Fukuoka, Japan
[2] Kyushu Univ, Fac Med Sci, Dept Hlth Sci, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
[3] Oita Prefectural Hosp, Oita, Japan
来源
关键词
Intramyocardial hemorrhage; Biomarker; Quantification; Semi-automated threshold method; Magnetic resonance imaging; Acute myocardial infarction; ELEVATION MYOCARDIAL-INFARCTION; LATE GADOLINIUM ENHANCEMENT; MICROVASCULAR OBSTRUCTION; ST-ELEVATION; MANAGEMENT; OUTCOMES; IMPACT; MRI;
D O I
10.1007/s10554-019-01697-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although intramyocardial hemorrhage (IMH) is a poor prognostic factor caused by ischemia reperfusion injury, little evidence is available regarding the association between IMH volume and biomarkers. In the present study, we measured IMH volume using three-dimensional (3D) T1-weighted magnetic resonance imaging (T1-MRI) and investigated its association with biomarkers. Moreover, the accuracy of semi-automatic measurement of IMH volume was validated. We retrospectively enrolled 33 consecutive patients (mean age 67 +/- 11 years) who underwent cardiac MRI after reperfusion therapy for acute myocardial infarction. IMH was observed in 4 patients (12.1%). Receiver operating characteristics (ROC) analysis of creatine kinase (CK) and CK-muscle/brain (CK-MB) tests for detecting IMH were performed. IMH volume measured using semi-automatic methods by a 2 standard deviation (SD) threshold was compared to manual measurements using the Spearman's correlation coefficient (rho) and Bland-Altman analyses. ROC analysis revealed optimal cutoff values of CK: 2460 IU/l and CK-MB: 231 IU/l (area under the curve: 0.95 and 0.91; sensitivity: 86% and 79%; specificity: 100% for both). IMH volume with the 2SD threshold correlated with that of the manual measurement [5.84 g (3.30 to 9.00) g vs. 8.07 g (5.37 to 9.33); rho: 0.85, p < 0.01; bias (limit of agreement): - 0.01 g (- 0.51 to 0.49); intraclass correlation coefficients 0.84 (0.75 to 0.90)]. Our findings could help identify the risk of IMH after reperfusion therapy with biomarkers. 3D T1-MRI can semi-automatically provide accurate IMH volume without being time-consuming.
引用
收藏
页码:111 / 119
页数:9
相关论文
共 38 条
  • [31] Noncontrast-Enhanced Three-Dimensional Magnetic Resonance Aortography of the Thorax at 3.0 T Using Respiratory-Compensated T1-Weighted k-Space Segmented Gradient-Echo Imaging With Radial Data Sampling Preliminary Study
    Amano, Yasuo
    Takahama, Katsuya
    Kumita, Shinichiro
    INVESTIGATIVE RADIOLOGY, 2009, 44 (09) : 548 - 552
  • [32] Magnetic resonance imaging of hyaline cartilage defects at 1.5T and 3.0T: Comparison of medium T2-weighted fast spin echo, T1-weighted two-dimensional and three-dimensional gradient echo pulse sequences (vol 46, pg 67, 2005)
    Fischbach, F
    Bruhn, H
    Unterhauser, F
    Ricke, J
    Wieners, G
    Felix, R
    Weiler, A
    Schroder, RJ
    ACTA RADIOLOGICA, 2005, 46 (02) : 218 - 218
  • [33] Fat-suppressed, three-dimensional T1-weighted imaging using high-acceleration parallel acquisition and a dual-echo Dixon technique for gadoxetic acid-enhanced liver MRI at 3T
    Yoon, Jeong Hee
    Lee, Jeong Min
    Yu, Mi Hye
    Kim, Eun Ju
    Han, Joon Koo
    Choi, Byung Ihn
    ACTA RADIOLOGICA, 2015, 56 (12) : 1454 - 1462
  • [34] Magnetic resonance imaging with three-dimensional fast imaging employing steady-state acquisition with phase-cycled and short T1 inversion recovery pulse sequence for evaluating brachial plexus injury
    Ning, Dianxiu
    Sun, Meiyu
    Sun, Bo
    Zhao, Li
    Zhang, Weisheng
    Wang, Lijun
    Wang, Shaowu
    Liu, Ailian
    Wu, Jianlin
    Lang, Zhijin
    Ning, Di
    Liu, Guanfu
    Ji, Xiaochen
    Wang, Xiufeng
    NEURAL REGENERATION RESEARCH, 2011, 6 (14) : 1097 - 1102
  • [36] Evaluation of lumber nerve root compression using thin-slice thickness coronal magnetic resonance imaging: three-dimensional fat-suppressed multi-shot balanced non-steady-state free precession versus three-dimensional T1-weighted spoiled gradient-recalled echo
    Tanitame, Keizo
    Tanitame, Nobuko
    Tani, Chihiro
    Ishikawa, Masaki
    Takasu, Miyuki
    Date, Shuji
    Otani, Keiko
    Awai, Kazuo
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (09) : 623 - 629
  • [37] Magnetic Resonance Imaging in Patients With Mechanical Low Back Pain Using a Novel Rapid-Acquisition Three-Dimensional SPACE Sequence at 1.5-T: A Pilot Study Comparing Lumbar Stenosis Assessment With Routine Two-Dimensional Magnetic Resonance Sequences
    Swami, Vimarsha G.
    Katlariwala, Mihir
    Dhillon, Sukhvinder
    Jibri, Zaid
    Jaremko, Jacob L.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2016, 67 (04): : 368 - 378
  • [38] Evaluation of lumber nerve root compression using thin-slice thickness coronal magnetic resonance imaging: three-dimensional fat-suppressed multi-shot balanced non-steady-state free precession versus threedimensional T1-weighted spoiled gradient-recalled echo
    Keizo Tanitame
    Nobuko Tanitame
    Chihiro Tani
    Masaki Ishikawa
    Miyuki Takasu
    Shuji Date
    Keiko Otani
    Kazuo Awai
    Japanese Journal of Radiology, 2011, 29 : 623 - 629