Electrochemical determination of Saccharomyces cerevisiae sp using glassy carbon electrodes modified with oxidized multi-walled carbon nanotubes dispersed in water -Nafion®

被引:3
|
作者
Acevedo Restrepo, Isabel [1 ]
Blandon Naranjo, Lucas [1 ]
Hoyos-Arbelaez, Jorge [2 ]
Victor Vazquez, Mario [1 ]
Gutierrez Granados, Silvia [3 ]
Palacio, Juliana [4 ]
机构
[1] Univ Antioquia, Fac Exact & Nat Sci, Chem Inst, Interdiscliplinary Grp Mol Studies GIEM, St 67 53-108, Medellin, Colombia
[2] Univ Antioquia, Fac Pharmaceut & Food Sci, Food Dept, BIOALI Res Grp, St 67 53-108, Medellin, Colombia
[3] Univ Guanajuato, Dept Chem, Div Exact & Nat Sci, Campus Guanajuato,Cerro Venada S-N, Guanajuato 36040, Mexico
[4] Univ Antioquia, Fac Exact & Nat Sci, Chem Inst, Mat Sci Res Grp, St 70 52-21, Medellin, Colombia
来源
关键词
Yeast; Saccharomyces cerevisiae sp; Glassy carbon electrodes; Nafion (R); Oxidized multi-walled carbon nanotubes; Electrochemical determination; NAFION; WINE; FERMENTATION; ADSORPTION; EXPRESSION; BIOSENSOR; CELLS;
D O I
10.1016/j.crfs.2022.01.022
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The electrochemical behavior of Saccharomyces cerevisiae sp was studied using a glassy carbon electrode (GCE) modified with Nafion-dispersed oxidized multi-walled carbon nanotubes (OMWCNT). The morphology was studied using scanning electron microscopy (SEM), showing that the yeast sticks to the carbon nanotube surface instead of the glassy carbon surface. The redox couple Fe(CN)(6)(4-)/Fe(CN)(6)(3-) was used to determine the electroactive area and the heterogeneous transfer constant, which increased 80.5% and 108% respectively by the presence of nanotubes. The studies of the pH effect showed that the anodic potential decreases at alkaline pH and that the highest current intensity occurs at a pH value of 7.00. Studies of the scan rate effect have shown that yeast oxidation is an irreversible mixed control process in which two electrons participate. The relationship between yeast concentration and the anodic current density was studied using different electrochemical techniques obtaining the best analytical parameters through chronoamperometry. The linear range was between 3.36 and 6.52 g L-1, the limit of detection (LOD) and the limit of quantification (LOQ) were 0.98 g L-1 and 3.36 g L-1 respectively, and the sensibility obtained was 0.086 mu A L g(-1) mm(-2). These results show that the multi-walled carbon nanotubes in water and Nafion (R) allow obtaining an anodic signal corresponding to the yeast, which facilitates its quantification through electrochemical methodologies, favoring the reduction of analysis times and costs compared with other techniques.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 50 条
  • [31] An application of a glassy carbon electrode and a glassy carbon electrode modified with multi-walled carbon nanotubes in electroanalytical determination of oxycarboxin
    Leniart, Andrzej
    Brycht, Mariola
    Burnat, Barbara
    Skrzypek, Sawomira
    IONICS, 2018, 24 (07) : 2111 - 2121
  • [32] An application of a glassy carbon electrode and a glassy carbon electrode modified with multi-walled carbon nanotubes in electroanalytical determination of oxycarboxin
    Andrzej Leniart
    Mariola Brycht
    Barbara Burnat
    Sławomira Skrzypek
    Ionics, 2018, 24 : 2111 - 2121
  • [33] Electrochemical Determination of Dopamine at Pre-Anodized Helical Multi-Walled Carbon Nanotubes Modified Glassy Carbon Electrode
    Li, Zhiguo
    Jia, Yongmei
    Liu, Yuge
    Ye, Cui
    Hua, Guifang
    Zhong, Yiping
    Zhang, Lingling
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (02)
  • [34] Voltammetric determination of the herbicide propham on glassy carbon electrode modified with multi-walled carbon nanotubes
    Leniart, Andrzej
    Brycht, Mariola
    Burnat, Barbara
    Skrzypek, Slawomira
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 231 : 54 - 63
  • [35] A Novel Glassy Carbon Electrode Modified with Multi-Walled Carbon Nanotubes for Potentiometric Xipamide Determination
    Tantawy, Mahmoud A.
    El Fiky, Haitham A.
    Badawey, Amr M.
    Ghany, Maha F. Abd El
    Fares, Nermine, V
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (05)
  • [36] Voltammetric oxidation and determination of cinnarizine at glassy carbon electrode modified with multi-walled carbon nanotubes
    Hegde, Rajesh N.
    Hosamani, Ragunatharaddi R.
    Nandibewoor, Sharanappa T.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 72 (02) : 259 - 265
  • [37] ELECTROOXIDATION OF DNA AT GLASSY CARBON ELECTRODES MODIFIED WITH MULTI-WALLED CARBON NANOTUBES WITH DIFFERENT OXIDATION DEGREE
    Canete-Rosales, Paulina
    Alvarez-Lueje, Alejandro
    Bollo, Soledad
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2014, 59 (02): : 2494 - 2497
  • [38] Sensitive detection of haloperidol and hydroxyzine at multi-walled carbon nanotubes-modified glassy carbon electrodes
    Huang, Fei
    Peng, Youyuan
    Jin, Guiying
    Zhang, Song
    Kong, Jilie
    SENSORS, 2008, 8 (03) : 1879 - 1889
  • [39] ELECTROCHEMICAL DETERMINATION OF ACETAMINOPHEN AT THE SURFACE OF A GLASSY CARBON ELECTRODE MODIFIED WITH MULTI-WALLED CARBON NANOTUBE
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsen
    Hajisadeghian, Elahe
    Golestaneh, Mahshid
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2013, 58 (01): : 1513 - 1516
  • [40] Direct Electrochemical Reaction of Phytohemagglutinin Adsorbed at the Multi-Walled Carbon Nanotubes Modified Glassy Carbon Electrode
    Madrakian, Tayyebeh
    Bagheri, Habibollah
    Afkhami, Abbas
    Rad, Abdolkarim Chehregani
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2014, 161 (06) : G37 - G42