ELECTROCHEMICAL DETERMINATION OF ACETAMINOPHEN AT THE SURFACE OF A GLASSY CARBON ELECTRODE MODIFIED WITH MULTI-WALLED CARBON NANOTUBE

被引:0
|
作者
Ghoreishi, Sayed Mehdi [1 ]
Behpour, Mohsen [1 ]
Hajisadeghian, Elahe [1 ]
Golestaneh, Mahshid [1 ]
机构
[1] Univ Kashan, Fac Chem, Dept Analyt Chem, Kashan, Iran
来源
关键词
Acetaminophen; Carbon nanotubes; Glassy carbon electrode; Electrochemical determination; VOLTAMMETRIC DETERMINATION; DERIVATIVE SPECTROPHOTOMETRY; LIQUID-CHROMATOGRAPHY; PARACETAMOL; FILM; MICROELECTRODE; INJECTION; DOPAMINE; BEHAVIOR; SENSOR;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A multi-walled carbon nanotubes (MWCNTs) film coated glassy carbon electrode (GCE) was fabricated, and the electrochemical behavior of acetaminophen (AAP) was studied in Britton-Robinson (BR) buffer (pH 7.0), using cyclic voltammetry (CV), square-wave voltammetry (SWV) and differential pulse voltammetry (DPV). Cyclic voltammograms of AAP showed enhanced redox responses for the MWCNT/GCE with respect to the bare GCE. The anodic peak potential shifted to less positive values by increasing the pH. The electrochemical oxidation of AAP at MWCNT/GCE was quasi-reversible and diffusion-controlled. Experimental parameters, such as pH, scan rate, SW frequency and step height, were optimized for AAP measurement. Under the optimum pH of 7.0 in 0.1 M BR buffer solution, the DPV anodic peak current showed a linear relation versus AAP concentration in the range of 7.9x10(-7) to 3.4x10(-4) M with a detection limit of 3.3x10(-7) for DPV, and from 6.5x10(-7) to 3.5x10(-4) M for SWV with a detection limit of 2.1x10(-7) (signal to noise = 3). Moreover, this method demonstrated good reproducibility (RSD = 1.3%, n = 10) and long-term stability. These have been applied to the determination of AAP in effervescent dosage samples.
引用
收藏
页码:1513 / 1516
页数:4
相关论文
共 50 条
  • [1] Voltammetric determination of resorcinol on the surface of a glassy carbon electrode modified with multi-walled carbon nanotube
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsem
    Hajisadeghian, Elahe
    Golestaneh, Mahshid
    ARABIAN JOURNAL OF CHEMISTRY, 2016, 9 : S1563 - S1568
  • [2] Determination of Eriodictyol by a Modified Multi-Walled Carbon Nanotube Glassy Carbon Electrode
    Cai, Wan-Ling
    Liu, Ling
    Liao, Xue-Qing
    Tao, Kai-Li
    Feng, Fang
    Yang, Gong-Jun
    ANALYTICAL LETTERS, 2016, 49 (10) : 1502 - 1512
  • [3] Electrochemical Behavior and Voltammetric Determination of Sulfaguanidine at a Glassy Carbon Electrode Modified With a Multi-Walled Carbon Nanotube
    Fotouhi, Lida
    Fatollahzadeh, Maryam
    Heravi, Majid M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (05): : 3919 - 3928
  • [4] Electrochemical determination of fluvoxamine on mercury nanoparticle multi-walled carbon nanotube modified glassy carbon electrode
    Madrakian, Tayyebeh
    Soleimani, Mohammad
    Afkhami, Abbas
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 259 - 266
  • [5] Multi-Walled Carbon Nanotube Modified Glassy Carbon Electrode as a Sensor for the Determination of Raloxifene Hydrochloride
    Kalanur, Shankara S.
    Seetharamappa, J.
    SENSOR LETTERS, 2011, 9 (04) : 1403 - 1409
  • [6] A Sensitive Determination of Acetaminophen in Pharmaceutical Preparations and Biological Samples using Multi-Walled Carbon Nanotube Modified Glassy Carbon Electrode
    Babaei, Ali
    Afrasiabi, Mohammad
    Mirzakhani, Somaieh
    Taheri, Ali Reza
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2011, 22 (02) : 344 - 351
  • [7] A Sensitive Simultaneous Determination of Acetaminophen and Indomethacin at Multi-walled Carbon Nanotubes Modified Glassy Carbon Electrode
    Babaei, Ali
    Farshbaf, Mojtaba
    Afrasiabi, Mohammad
    Dehdashti, Aliyeh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (06): : 564 - 578
  • [8] Multi-walled carbon nanotube modified glassy carbon electrode as curcumin sensor
    Mustafa Cittan
    Esra Altuntaş
    Ali Çelik
    Monatshefte für Chemie - Chemical Monthly, 2020, 151 : 881 - 888
  • [9] A Sensor for Simultaneous Determination of Acetaminophen and Codeine at Glassy Carbon Electrode Modified with Multi-Walled Carbon Nanotubes
    Babaei, Ali
    Dehdashti, Aliyeh
    Afrasiabi, Mohammad
    Babazadeh, Mitra
    Farshbaf, Mojtaba
    Bamdad, Farzad
    SENSOR LETTERS, 2012, 10 (3-4) : 1039 - 1046
  • [10] Multi-walled carbon nanotube modified glassy carbon electrode as curcumin sensor
    Cittan, Mustafa
    Altuntas, Esra
    Celik, Ali
    MONATSHEFTE FUR CHEMIE, 2020, 151 (06): : 881 - 888