Optimization of derivative kernels for exact cone-beam ROI reconstruction in spiral computed tomography

被引:0
|
作者
Lauritsch, G [1 ]
Sourbelle, K
Tam, KC
机构
[1] Seimens Med Solut, D-91050 Erlangen, Germany
[2] Univ Erlangen Nurnberg, IMP, D-91054 Erlangen, Germany
[3] Siemens Corp Res Inc, Princeton, NJ 08540 USA
关键词
cone-beam computed tomography (CT); cone-beam filtered backprojection (FBP); algorithms; filter design; finite differences; linogram; local region-of-interest (ROI) algorithm; numerical derivative; ringing artifacts; spiral CT; three-dimensional (3-D) radon inversion; windowed filter kernels;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A recent comparison study showed that exact filtered backprojection (FBP)-based solutions of the long object problem are numerically stable and that their image quality is mostly affected by filter design. In this paper, the impact of the kernel design on image. quality is demonstrated systematically in the case of the local region-of-interest (ROI) algorithm. First of all, the implementation is improved by the use of the Linogram technique to eliminate interpolations in the filter step and to speed up computation. In the case of the local ROI method, favorable kernels for one-dimensional (1-D) partial derivatives have to be designed. Finite differences are fast to compute but cause ringing artifacts. More sophisticated kernels can be designed in a straightforward manner in Fourier space, identifying the window function most appropriate to a given application. No ringing artifacts are observed for the windowed kernels under investigation. In addition, windowed kernels are superior to the finite differences regarding the spatial resolution versus noise properties. For partial derivatives in directions with data truncation the projection data have to be extrapolated before convolution. Alternatively, very short derivative kernels can be used, generally at a decreased image quality. Kernels of different design and length can be combined.
引用
收藏
页码:728 / 732
页数:5
相关论文
共 50 条
  • [31] Operational principles for cone-beam computed tomography
    Hatcher, David C.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (10): : 3S - 6S
  • [32] Cone-Beam Computed Tomography: Beyond Diagnostics
    Perel, Morton L.
    IMPLANT DENTISTRY, 2015, 24 (04) : 367 - 367
  • [33] Improved scanning and reconstruction of large objects by cone-beam industrial computed, tomography
    Zeng, Li
    Zou, Xiaobing
    Wang, Jue
    Wang, Ping
    Hunziker, Patrick R.
    PROCEEDINGS OF THE NINTH IASTED INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING, 2007, : 46 - +
  • [34] Investigation of effect of reconstruction filters on cone-beam computed tomography image quality
    Srinivasan, Kavitha
    Mohammadi, Mohammad
    Shepherd, Justin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (03) : 607 - 614
  • [35] non-isocentric cone-beam computed tomography reconstruction and artifact suppression
    Keuschnigg, P.
    Deutschmann, H.
    Weichenberger, H.
    Sedlmayer, F.
    Steininger, P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S113 - S114
  • [36] Interior Reconstruction from Truncated Projection Data in Cone-beam Computed Tomography
    Wang Xianchao
    Li Shaoyi
    Hou Changhui
    Journal of Digital Imaging, 2023, 36 : 250 - 258
  • [37] Performance of approximate cone-beam reconstruction in multi-slice computed tomography
    Bruder, H
    Kachelriess, M
    Schaller, S
    Mertelmeier, T
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 541 - 553
  • [38] Interior Reconstruction from Truncated Projection Data in Cone-beam Computed Tomography
    Wang Xianchao
    Li Shaoyi
    Hou Changhui
    JOURNAL OF DIGITAL IMAGING, 2023, 36 (01) : 250 - 258
  • [39] Respiration phase-based cone-beam computed tomography (CBCT) reconstruction
    Yan, H.
    Godfrey, D.
    Yin, F.
    MEDICAL PHYSICS, 2006, 33 (06) : 2047 - 2047
  • [40] Investigation of effect of reconstruction filters on cone-beam computed tomography image quality
    Kavitha Srinivasan
    Mohammad Mohammadi
    Justin Shepherd
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 607 - 614