Clinical Performance, Patient Reported Outcome, and Radiological Results of a Short, Tapered, Porous, Proximally Coated Cementless Femoral Stem: Results up to Seven Years of Follow-Up

被引:25
|
作者
Ulivi, Michele [1 ]
Orlandini, Luca C. [1 ]
Meroni, Valentina [1 ]
Lombardo, Michele D. M. [2 ]
Peretti, Giuseppe M. [1 ,3 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, Milan, Italy
[2] Univ Milan, Residency Program Orthoped & Traumatol, Via Festa Perdono 7, I-20122 Milan, Italy
[3] Univ Milan, Dept Biomed Sci Hlth, Milan, Italy
来源
JOURNAL OF ARTHROPLASTY | 2018年 / 33卷 / 04期
关键词
hip osteoarthritis; total hip arthroplasty; short stem prosthesis; osseointegration; radiographic evaluation; patient reported outcome; TOTAL HIP-ARTHROPLASTY; COBALT-CHROME; COMPONENT; 10-YEAR; REPLACEMENT; FIXATION; IMPLANTS; BONE;
D O I
10.1016/j.arth.2017.11.046
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The primary aim of our study was to assess clinical performance, patient reported outcome and radiological results of cementless primary total hip arthroplasty using Tri-Lock Bone Preservation Stem. Methods: Between March 2010 and June 2012, 163 consecutive patients, were enrolled in the study. Patients were assessed clinically and radiographically prior to surgery as well as at 6, 12, 24 months and then at 5, 6, and 7 years postoperatively. Results: Using the Dorr classification, 39 patients (23.9%) were classified as Dorr A, 116 patients (71.2%) as Dorr B, and 8 patients (4.9%) as Dorr C. A total of 139 patients (85.3%) received a high offset, whereas 24 patients (14.7%) received a standard offset stem. Total Harris Hip Score of the patients increased from a mean of 27.29 (+/- 4.6) preoperatively, upto 97.28 (+/- 9.0) after 5 years. Mean preoperative Short Form-12 (SF-12) Physical Health Composite Scale score was 27.31 (+/- 3.8). After 5 year was 55.3 (34-57). The mean preoperative SF-12 Mental Health Composite Scale score was 57.02 (+/- 5.9). After 5 year was 59.3 (28.7-60.8). Only one patient underwent revision surgery for dislocation and revision of the head. Conclusion: Tri-lock Bone Preservation Stem DePuy proved to be an easy-to-use device. Results obtained up to 7 years of FU show excellent clinical performance, as well as radiographic osseointegration, with no cases of aseptic loosening and no images of progressive radiolucent lines or periprosthetic osteolysis. (c) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:1133 / 1138
页数:6
相关论文
共 50 条
  • [41] Seven-year clinical follow-up after lumbar disc surgery:: results and predictors of outcome
    Graver, V
    Haaland, AK
    Magnæs, B
    Loeb, M
    BRITISH JOURNAL OF NEUROSURGERY, 1999, 13 (02) : 178 - 184
  • [42] Total hip arthroplasty with an uncemented hydroxyapatite-coated tapered titanium stem:: results at a minimum of 10 years' follow-up in 104 hips
    Bodén, H
    Salemyr, M
    Sköldenberg, O
    Ahl, T
    Adolphson, P
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2006, 11 (02) : 175 - 179
  • [43] Late Relapse of Acute Promyelocytic Leukemia: Literature Review and Results of Seven Years of Clinical and Laboratory Follow-Up of a Korean Patient
    Kim, Min Jin
    Cho, Sun Young
    Lee, Hee Joo
    Suh, Jin-Tae
    Lee, Woo-In
    Lee, Juhie
    Baek, Sun Kyung
    Yoon, Hwi-Joong
    Park, Tae Sung
    LABMEDICINE, 2012, 43 (05): : 205 - 211
  • [44] Clinical and radiological follow-up results of patients with untreated TMJ closed lock
    Imirzalioglu, P
    Biler, N
    Agildere, AM
    JOURNAL OF ORAL REHABILITATION, 2005, 32 (05) : 326 - 331
  • [45] Long-term follow-up of an uncemented proximally hydroxyapatite-coated femoral stem in total hip arthroplasty
    Yee, A. H. F.
    Chan, V. W. K.
    Fu, H.
    Chan, P-K
    Chiu, K. Y.
    BONE & JOINT JOURNAL, 2024, 106B (03): : 110 - 114
  • [46] The effect of incomplete patient follow-up on the reported results of AVM radiosurgery - Commentary
    Lawton, MT
    Spetzler, RF
    SURGICAL NEUROLOGY, 1998, 49 (04): : 384 - 384
  • [47] Primary total hip arthroplasty with a proximally HA-coated titanium femoral component: results at 10–15-year follow-up
    Sandiford N.A.
    Butler-Manuel A.
    Apthorp H.D.
    East D.J.
    Hinves B.L.
    Shepperd J.A.N.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (7) : 1211 - 1215
  • [48] Clinical and radiological outcome at mean follow-up of 11 years after hip arthroscopy
    Martin Olach
    Pascal Gerhard
    Karlmeinrad Giesinger
    Christoph Lampert
    Johannes B. Erhardt
    Archives of Orthopaedic and Trauma Surgery, 2019, 139 : 1 - 6
  • [49] Clinical and radiological outcome at mean follow-up of 11 years after hip arthroscopy
    Olach, Martin
    Gerhard, Pascal
    Giesinger, Karlmeinrad
    Lampert, Christoph
    Erhardt, Johannes B.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (01) : 1 - 6
  • [50] Clinical and radiographic results of cementless reverse total shoulder arthroplasty: a comparative study with 2 to 5 years of follow-up
    Wiater, J. Michael
    Moravek, James E., Jr.
    Budge, Matthew D.
    Koueiter, Denise M.
    Marcantonio, David
    Wiater, Brett P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (08) : 1208 - 1214