Clinical Performance, Patient Reported Outcome, and Radiological Results of a Short, Tapered, Porous, Proximally Coated Cementless Femoral Stem: Results up to Seven Years of Follow-Up

被引:25
|
作者
Ulivi, Michele [1 ]
Orlandini, Luca C. [1 ]
Meroni, Valentina [1 ]
Lombardo, Michele D. M. [2 ]
Peretti, Giuseppe M. [1 ,3 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, Milan, Italy
[2] Univ Milan, Residency Program Orthoped & Traumatol, Via Festa Perdono 7, I-20122 Milan, Italy
[3] Univ Milan, Dept Biomed Sci Hlth, Milan, Italy
来源
JOURNAL OF ARTHROPLASTY | 2018年 / 33卷 / 04期
关键词
hip osteoarthritis; total hip arthroplasty; short stem prosthesis; osseointegration; radiographic evaluation; patient reported outcome; TOTAL HIP-ARTHROPLASTY; COBALT-CHROME; COMPONENT; 10-YEAR; REPLACEMENT; FIXATION; IMPLANTS; BONE;
D O I
10.1016/j.arth.2017.11.046
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The primary aim of our study was to assess clinical performance, patient reported outcome and radiological results of cementless primary total hip arthroplasty using Tri-Lock Bone Preservation Stem. Methods: Between March 2010 and June 2012, 163 consecutive patients, were enrolled in the study. Patients were assessed clinically and radiographically prior to surgery as well as at 6, 12, 24 months and then at 5, 6, and 7 years postoperatively. Results: Using the Dorr classification, 39 patients (23.9%) were classified as Dorr A, 116 patients (71.2%) as Dorr B, and 8 patients (4.9%) as Dorr C. A total of 139 patients (85.3%) received a high offset, whereas 24 patients (14.7%) received a standard offset stem. Total Harris Hip Score of the patients increased from a mean of 27.29 (+/- 4.6) preoperatively, upto 97.28 (+/- 9.0) after 5 years. Mean preoperative Short Form-12 (SF-12) Physical Health Composite Scale score was 27.31 (+/- 3.8). After 5 year was 55.3 (34-57). The mean preoperative SF-12 Mental Health Composite Scale score was 57.02 (+/- 5.9). After 5 year was 59.3 (28.7-60.8). Only one patient underwent revision surgery for dislocation and revision of the head. Conclusion: Tri-lock Bone Preservation Stem DePuy proved to be an easy-to-use device. Results obtained up to 7 years of FU show excellent clinical performance, as well as radiographic osseointegration, with no cases of aseptic loosening and no images of progressive radiolucent lines or periprosthetic osteolysis. (c) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:1133 / 1138
页数:6
相关论文
共 50 条
  • [31] Long-Term Results Using the Straight Tapered Femoral Cementless Hip Stem in Total Hip Arthroplasty: A Minimum of Twenty-Year Follow-Up
    Ateschrang, Atesch
    Weise, Kuno
    Weller, Siegfried
    Stoeckle, Ulrich
    de Zwart, Peter
    Ochs, Bjoern Gunnar
    JOURNAL OF ARTHROPLASTY, 2014, 29 (08): : 1559 - 1565
  • [32] The results of mitoxantrone therapy with three years of clinical follow-up
    Agaoglu, J
    Emir, C
    Kale, N
    Onder, G
    Tanik, O
    MULTIPLE SCLEROSIS, 2004, 10 (7032): : S266 - S266
  • [33] Seven-year Results of a Tapered, Titanium, Hydroxyapatite-Coated Cementless Femoral Stem in Primary Total Hip Arthroplasty
    Cho, Jin-Ho
    Garino, Jonathan P.
    Choo, Suk-Kyu
    Han, Kye-Young
    Kim, Jung-Hoon
    Oh, Hyoung-Keun
    CLINICS IN ORTHOPEDIC SURGERY, 2010, 2 (04) : 214 - 220
  • [34] Mid- to long-term clinical and radiological assessment of a short, titanium, porous plasma-splayed flat-tapered cementless femoral stem: An 8-to 12-year follow-up study
    Yoshino, Kensuke
    Harada, Yoshitada
    Miyagi, Jin
    Ogawa, Yuya
    Nagai, Akito
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 145 (01)
  • [35] Seven years follow-up of the "Growth Stent": results in infants with aortic coarctation
    Ewert, P.
    Schubert, S.
    Peters, B.
    Ovroutski, S.
    Miera, O.
    Nagdyman, N.
    Berger, F.
    CLINICAL RESEARCH IN CARDIOLOGY, 2011, 100 (09) : 821 - 821
  • [36] Clinical experience with a proximally porous-coated second-generation cementless total hip prosthesis - Minimum 5-year follow-up
    Mont, MA
    Yoon, TR
    Krackow, KA
    Hungerford, DS
    JOURNAL OF ARTHROPLASTY, 1999, 14 (08): : 930 - 939
  • [37] Results of a cemented straight titanium alloy femoral stem after mean follow-up of 13 years
    Eingartner, C.
    Piel, S.
    Weise, K.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2007, 17 (06): : 587 - 593
  • [38] CEMENTLESS THR IN YOUNG-PATIENTS USING A POROUS-COATED FEMORAL IMPLANT - 2-7 YEARS FOLLOW-UP
    MALCHAU, H
    HERBERTS, P
    ROMANUS, B
    WIKLUND, LM
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (04): : 447 - 447
  • [39] The Synergy cementless femoral stem in primary total hip arthroplasty at a minimum follow-up of 15 years
    De Martino, I.
    De Santis, V.
    D'Apolito, R.
    Sculco, P. K.
    Cross, M. B.
    Gasparini, G.
    BONE & JOINT JOURNAL, 2017, 99B (01): : 29 - 36
  • [40] Cementless acetabular revision with the Harris-Galante Porous prosthesis - Results after a minimum of ten years of follow-up
    Hallstrom, BR
    Golladay, GJ
    Vittetoe, DA
    Harris, WH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05): : 1007 - 1011