Segmental and global left ventricular function assessment using gated SPECT with a semiconductor Cadmium Zinc Telluride (CZT) camera: Phantom study and clinical validation vs cardiac magnetic resonance

被引:20
|
作者
Bailliez, Alban [1 ,4 ]
Blaire, Tanguy [1 ,4 ]
Mouquet, Frederic [2 ]
Legghe, R. [1 ]
Etienne, B. [1 ]
Legallois, Damien [3 ,4 ]
Agostini, Denis [3 ,4 ]
Manrique, Alain [3 ,4 ]
机构
[1] Polyclin Bois, IRIS, Dept Nucl Med, F-59000 Lille, France
[2] Polyclin Bois, F-59000 Lille, France
[3] CHU Caen, Dept Nucl Med, F-14000 Caen, France
[4] Normandie Univ, EA4650, Caen, France
关键词
CZT; SPECT; myocardial perfusion imaging; solid-state cardiac camera; left ventricular function; wall thickening; wall motion; cardiac magnetic resonance; tetrofosmin; MYOCARDIAL-PERFUSION SPECT; EJECTION FRACTION; QUANTIFICATION; REPRODUCIBILITY; VOLUME; TECHNETIUM-99M-MIBI; TOMOGRAPHY; CARDIOLOGY; RADIATION; SESTAMIBI;
D O I
10.1007/s12350-014-9899-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated gated-SPECT using a Cadmium-Zinc-Telluride (CZT) camera for assessing global and regional left ventricular (LV) function. A phantom study evaluated the accuracy of wall thickening assessment using systolic count increase on both Anger and CZT (Discovery 530NMc) cameras. The refillable phantom simulated variable myocardial wall thicknesses. The apparent count increase (%CI) was compared to the thickness increase (%Th). CZT gated-SPECT was compared to cardiac magnetic resonance (CMR) in 27 patients. Global and regional LV function (wall thickening and motion) were quantified and compared between SPECT and CMR data. In the phantom study using a 5-mm object, the regression between %CI and %Th was significantly closer to the line of identity (y = x) with the CZT (R (2) = 0.9955) than the Anger (R (2) = 0.9995, P = .03). There was a weaker correlation for larger objects (P = .003). In patients, there was a high concordance between CZT and CMR for ESV, EDV, and LVEF (all CCC > 0.80, P < .001). CZT underestimated %CI and wall motion (WM) compared to CMR (P < .001). The agreement to CMR was better for WM than wall thickening. The Discovery 530NMc provided accurate measurements of global LV function but underestimated regional wall thickening, especially in patients with increased wall thickness.
引用
收藏
页码:712 / 722
页数:11
相关论文
共 45 条
  • [41] Assessment of left ventricular diastolic and systolic function in patients with heart failure using steady state cine magnetic resonance imaging: Validation study using conductance catheter
    Uemura, S
    Sakuma, H
    Motoyasu, M
    Onishi, K
    Tanabe, M
    Dohi, W
    Okinaka, T
    Isaka, N
    Takeda, K
    Nakano, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 443A - 443A
  • [42] Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: A comparison with cardiac magnetic resonance
    Annuar, Bin Rapaee
    Liew, Chee Khoon
    Chin, Sze Piaw
    Ong, Tiong Kiam
    Seyfarth, M. Tobias
    Chan, Wei Ling
    Fong, Yean Yip
    Ang, Choon Kiat
    Lin, Naing
    Liew, Houng Bang
    Sim, Kui Hian
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (01) : 112 - 119
  • [43] Assessment of regional and global left ventricular function by reinjection Tl-201 and rest Tc-99m sestamibi ECG-gated SPECT - Comparison with three-dimensional magnetic resonance imaging
    Tadamura, E
    Kudoh, T
    Motooka, M
    Inubushi, M
    Shirakawa, S
    Hattori, N
    Okada, T
    Matsuda, T
    Koshiji, T
    Nishimura, K
    Matsuda, K
    Konishi, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (04) : 991 - 997
  • [44] Assessment of global and regional left ventricular function using 64-row multi detector computed tomography and 2D echocardiography: A comparison with cardiac magnetic resonance
    Rapaee, A.
    Liew, C. K.
    Chin, S. P.
    Ong, T. K.
    Chan, W. L.
    Ang, C. K.
    Seyfarth, M. T.
    Sim, K. H.
    EUROPEAN HEART JOURNAL, 2006, 27 : 423 - 423
  • [45] Left Ventricular Global Function Index by Magnetic Resonance Imaging-A Novel Marker for Assessment of Cardiac Performance for the Prediction of Cardiovascular Events The Multi-Ethnic Study of Atherosclerosis
    Mewton, Nathan
    Opdahl, Anders
    Choi, Eui-Young
    Almeida, Andre L. C.
    Kawel, Nadine
    Wu, Colin O.
    Burke, Gregory L.
    Liu, Songtao
    Liu, Kiang
    Bluemke, David A.
    Lima, Joao A. C.
    HYPERTENSION, 2013, 61 (04) : 770 - +