Segmental and global left ventricular function assessment using gated SPECT with a semiconductor Cadmium Zinc Telluride (CZT) camera: Phantom study and clinical validation vs cardiac magnetic resonance

被引:20
|
作者
Bailliez, Alban [1 ,4 ]
Blaire, Tanguy [1 ,4 ]
Mouquet, Frederic [2 ]
Legghe, R. [1 ]
Etienne, B. [1 ]
Legallois, Damien [3 ,4 ]
Agostini, Denis [3 ,4 ]
Manrique, Alain [3 ,4 ]
机构
[1] Polyclin Bois, IRIS, Dept Nucl Med, F-59000 Lille, France
[2] Polyclin Bois, F-59000 Lille, France
[3] CHU Caen, Dept Nucl Med, F-14000 Caen, France
[4] Normandie Univ, EA4650, Caen, France
关键词
CZT; SPECT; myocardial perfusion imaging; solid-state cardiac camera; left ventricular function; wall thickening; wall motion; cardiac magnetic resonance; tetrofosmin; MYOCARDIAL-PERFUSION SPECT; EJECTION FRACTION; QUANTIFICATION; REPRODUCIBILITY; VOLUME; TECHNETIUM-99M-MIBI; TOMOGRAPHY; CARDIOLOGY; RADIATION; SESTAMIBI;
D O I
10.1007/s12350-014-9899-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated gated-SPECT using a Cadmium-Zinc-Telluride (CZT) camera for assessing global and regional left ventricular (LV) function. A phantom study evaluated the accuracy of wall thickening assessment using systolic count increase on both Anger and CZT (Discovery 530NMc) cameras. The refillable phantom simulated variable myocardial wall thicknesses. The apparent count increase (%CI) was compared to the thickness increase (%Th). CZT gated-SPECT was compared to cardiac magnetic resonance (CMR) in 27 patients. Global and regional LV function (wall thickening and motion) were quantified and compared between SPECT and CMR data. In the phantom study using a 5-mm object, the regression between %CI and %Th was significantly closer to the line of identity (y = x) with the CZT (R (2) = 0.9955) than the Anger (R (2) = 0.9995, P = .03). There was a weaker correlation for larger objects (P = .003). In patients, there was a high concordance between CZT and CMR for ESV, EDV, and LVEF (all CCC > 0.80, P < .001). CZT underestimated %CI and wall motion (WM) compared to CMR (P < .001). The agreement to CMR was better for WM than wall thickening. The Discovery 530NMc provided accurate measurements of global LV function but underestimated regional wall thickening, especially in patients with increased wall thickness.
引用
收藏
页码:712 / 722
页数:11
相关论文
共 45 条
  • [21] Left ventricular function assessment using 123I/99mTc dual isotope acquisition with two semi-conductor cadmium zinc telluride (CZT) cameras: a dynamic cardiac phantom study
    Blaire, T.
    Bailliez, A.
    Legallois, D.
    Agostini, D.
    Manrique, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S211 - S211
  • [22] Absolute Quantification of Left Ventricular Global and Regional Function at Nuclear MPI Using Ultrafast CZT SPECT: Initial Validation Versus Cardiac MR
    Cochet, Hubert
    Bullier, Eric
    Gerbaud, Edouard
    Durieux, Muriel
    Godbert, Yann
    Lederlin, Mathieu
    Coste, Pierre
    Barat, Jean-Louis
    Laurent, Francois
    Montaudon, Michel
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (04) : 556 - 563
  • [23] Mutidetector-row CT and quantitative gated SPECT for the assessment of left ventricular function in small hearts: the cardiac physical phantom study using a combined SPECT/CT system
    Daisuke Utsunomiya
    Seiji Tomiguchi
    Kazuo Awai
    Shinya Shiraishi
    Takeshi Nakaura
    Yasuyuki Yamashita
    European Radiology, 2006, 16 : 1818 - 1825
  • [24] Mutidetector-row CT and quantitative gated SPECT for the assessment of left ventricular function in small hearts: the cardiac physical phantom study using a combined SPECT/CT system
    Utsunomiya, Daisuke
    Tomiguchi, Seiji
    Awai, Kazuo
    Shiraishi, Shinya
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    EUROPEAN RADIOLOGY, 2006, 16 (08) : 1818 - 1825
  • [25] Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac magnetic resonance as reference standard
    Helen Soneson
    Fredrik Hedeer
    Carmen Arévalo
    Marcus Carlsson
    Henrik Engblom
    Joey F. A. Ubachs
    Håkan Arheden
    Einar Heiberg
    Journal of Nuclear Cardiology, 2011, 18 : 874 - 885
  • [26] Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac magnetic resonance as reference standard
    Soneson, Helen
    Hedeer, Fredrik
    Arevalo, Carmen
    Carlsson, Marcus
    Engblom, Henrik
    Ubachs, Joey F. A.
    Arheden, Hakan
    Heiberg, Einar
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (05) : 874 - 885
  • [27] Clinical utilization of submillisievert stress only myocardial perfusion imaging and concurrent coronary artery calcium score: A single institutional experience of a novel cardiac SPECT camera using cadmium zinc telluride (CZT) semiconductor technology
    Liu, J.
    Hasche, E.
    Kilian, J.
    Dixson, H.
    Elison, B.
    Bui, C.
    Tie, H.
    Dunn, R.
    Smillie, C.
    Chiam, Q.
    Lee, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S73 - S73
  • [28] Assessment of left ventricular volumes and ejection fraction using ultra-low-dose thallium-201 SPECT on a CZT camera: a comparison with magnetic resonance imaging
    Sala, Marek
    Kincl, Vladimir
    Kaminek, Milan
    Vasina, Jiri
    Machal, Jan
    Panovsky, Roman
    Feitova, Vera
    Opatril, Lukas
    Holecek, Tomas
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (01) : 181 - 187
  • [29] Assessment of left ventricular volumes and ejection fraction using ultra-low-dose thallium-201 SPECT on a CZT camera: a comparison with magnetic resonance imaging
    Marek Sala
    Vladimír Kincl
    Milan Kamínek
    Jiří Vašina
    Jan Máchal
    Roman Panovský
    Věra Feitová
    Lukáš Opatřil
    Tomáš Holeček
    Journal of Nuclear Cardiology, 2022, 29 : 181 - 187
  • [30] Clinical Determinants of Global and Regional Left Ventricular Systolic Function by Cardiac Magnetic Resonance Imaging: The Jackson Heart Study
    Balfour, Pelbreton C.
    Musani, Solomon K.
    Williams, Renaldo
    Samdarshi, Tandaw S.
    Carr, Jeffrey
    Hundley, William C.
    Terry, Greg
    Taylor, Herman A.
    Ramachandran, Vasan S.
    Fox, Ervin
    CIRCULATION, 2012, 126 (21)