Segmental and global left ventricular function assessment using gated SPECT with a semiconductor Cadmium Zinc Telluride (CZT) camera: Phantom study and clinical validation vs cardiac magnetic resonance

被引:20
|
作者
Bailliez, Alban [1 ,4 ]
Blaire, Tanguy [1 ,4 ]
Mouquet, Frederic [2 ]
Legghe, R. [1 ]
Etienne, B. [1 ]
Legallois, Damien [3 ,4 ]
Agostini, Denis [3 ,4 ]
Manrique, Alain [3 ,4 ]
机构
[1] Polyclin Bois, IRIS, Dept Nucl Med, F-59000 Lille, France
[2] Polyclin Bois, F-59000 Lille, France
[3] CHU Caen, Dept Nucl Med, F-14000 Caen, France
[4] Normandie Univ, EA4650, Caen, France
关键词
CZT; SPECT; myocardial perfusion imaging; solid-state cardiac camera; left ventricular function; wall thickening; wall motion; cardiac magnetic resonance; tetrofosmin; MYOCARDIAL-PERFUSION SPECT; EJECTION FRACTION; QUANTIFICATION; REPRODUCIBILITY; VOLUME; TECHNETIUM-99M-MIBI; TOMOGRAPHY; CARDIOLOGY; RADIATION; SESTAMIBI;
D O I
10.1007/s12350-014-9899-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated gated-SPECT using a Cadmium-Zinc-Telluride (CZT) camera for assessing global and regional left ventricular (LV) function. A phantom study evaluated the accuracy of wall thickening assessment using systolic count increase on both Anger and CZT (Discovery 530NMc) cameras. The refillable phantom simulated variable myocardial wall thicknesses. The apparent count increase (%CI) was compared to the thickness increase (%Th). CZT gated-SPECT was compared to cardiac magnetic resonance (CMR) in 27 patients. Global and regional LV function (wall thickening and motion) were quantified and compared between SPECT and CMR data. In the phantom study using a 5-mm object, the regression between %CI and %Th was significantly closer to the line of identity (y = x) with the CZT (R (2) = 0.9955) than the Anger (R (2) = 0.9995, P = .03). There was a weaker correlation for larger objects (P = .003). In patients, there was a high concordance between CZT and CMR for ESV, EDV, and LVEF (all CCC > 0.80, P < .001). CZT underestimated %CI and wall motion (WM) compared to CMR (P < .001). The agreement to CMR was better for WM than wall thickening. The Discovery 530NMc provided accurate measurements of global LV function but underestimated regional wall thickening, especially in patients with increased wall thickness.
引用
收藏
页码:712 / 722
页数:11
相关论文
共 45 条
  • [1] Segmental and global left ventricular function assessment using gated SPECT with a semiconductor Cadmium Zinc Telluride (CZT) camera: Phantom study and clinical validation vs cardiac magnetic resonance
    Alban Bailliez
    Tanguy Blaire
    Frédéric Mouquet
    R. Legghe
    B. Etienne
    Damien Legallois
    Denis Agostini
    Alain Manrique
    Journal of Nuclear Cardiology, 2014, 21 : 712 - 722
  • [2] Dual isotope global and regional left ventricular function using semi- conductor cadmium zinc telluride (CZT) camera: a dynamic cardiac phantom study
    Blaire, T.
    Bailliez, A.
    Legallois, D.
    Desmonts, C.
    Agostini, D.
    Manrique, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S176 - S176
  • [3] Assessment of Systolic count increase in Tetrofosmin-99mTc Gated Myocardial SPECT using a semiconductor Cadmium Zinc Telluride (CZT) camera : a first phantom study
    Bailliez, A.
    Blaire, T.
    Agostini, D.
    Manrique, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S246 - S246
  • [4] Left Ventricular Function Assessment Using 2 Different Cadmium-Zinc-Telluride Cameras Compared with a γ-Camera with Cardiofocal Collimators: Dynamic Cardiac Phantom Study and Clinical Validation
    Bailliez, Alban
    Lairez, Olivier
    Merlin, Charles
    Piriou, Nicolas
    Legallois, Damien
    Blaire, Tanguy
    Agostini, Denis
    Valette, Frederic
    Manrique, Alain
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (09) : 1370 - 1375
  • [5] Left ventricular function assessment using a semiconductor Cadmium Zinc Telluride (CZT) camera: Impact of temporal sampling using 8-vs. 16-interval gating
    Pascal, Pierre
    Bailliez, Alban
    Blaire, Tanguy
    Arnould, Jean-Simon
    Agostini, Denis
    Manrique, Alain
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [6] Gated SPECT evaluation of left ventricular function using a CZT camera and a fast low-dose clinical protocol: comparison to cardiac magnetic resonance imaging
    Giorgetti, Assuero
    Masci, Pier Giorgio
    Marras, Gavino
    Rustamova, Yasmine K.
    Gimelli, Alessia
    Genovesi, Dario
    Lombardi, Massimo
    Marzullo, Paolo
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (12) : 1869 - 1875
  • [7] Gated SPECT evaluation of left ventricular function using a CZT camera and a fast low-dose clinical protocol: comparison to cardiac magnetic resonance imaging
    Assuero Giorgetti
    Pier Giorgio Masci
    Gavino Marras
    Yasmine K. Rustamova
    Alessia Gimelli
    Dario Genovesi
    Massimo Lombardi
    Paolo Marzullo
    European Journal of Nuclear Medicine and Molecular Imaging, 2013, 40 : 1869 - 1875
  • [8] Global and regional LV function assessment using two different semiconductor cadmium zinc telluride (CZT) cameras: a dynamic cardiac phantom study compared to conventional gamma camera with cardiofocal collimators
    Bailliez, A.
    Blaire, T.
    Legallois, D.
    Desmonts, C.
    Agostini, D.
    Manrique, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S148 - S148
  • [9] LV function assessment using a semiconductor Cadmium Zinc Telluride (CZT) camera: Impact of temporal sampling (8 vs 16 intervals)
    Pascal, P.
    Bailliez, A.
    Blaire, T.
    Agostini, D.
    Manrique, A.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2013, 37 (02): : 35 - 43
  • [10] Validation of left ventricular function using gated SPECT with a scintillation crystal and semiconductor detectors camera system: A study of dynamic myocardial phantom.
    Kubo, N
    Mabuchi, M
    Katoh, C
    Arai, H
    Tsukamoto, E
    Morita, Y
    Tamaki, N
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 199P - 200P