ESTIMATION OF CENTRAL AORTIC BLOOD PRESSURE FROM NON-INVASIVE CUFF PRESSURE OSCILLATION SIGNALS VIA SYSTEM IDENTIFICATION

被引:0
|
作者
Ghasemi, Zahra [1 ]
Kim, Chang-Sei [1 ]
Ginsberg, Eric [2 ]
Duell, John [2 ]
Gupta, Anuj [2 ]
Hahn, Jin-Oh [1 ]
机构
[1] Univ Maryland, College Pk, MD 20742 USA
[2] Univ Maryland, Baltimore, MD 21201 USA
基金
美国国家科学基金会;
关键词
WAVE-FORM; RADIAL TONOMETRY; RECONSTRUCTION; HYPERTENSION; VALIDATION; EXERCISE;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents a model-based system identification approach to estimation of central aortic blood pressure waveform from non-invasive cuff pressure oscillation signals. First, we developed a mathematical model that can reproduce the relationship between central aortic blood pressure waveform and non-invasive cuff pressure oscillation signals at diametric locations by combining models to represent wave propagation in the artery, arterial pressure-volume relationship, and mechanics of the occlusive cuff. Second, we formulated the problem of estimating central aortic blood pressure waveform from non-invasive cuff pressure oscillation signals into a system identification problem. Third, we showed the proof-of-concept of the approach using simulated central aortic blood pressure waveform and cuff pressure oscillation signals. Finally, we illustrated the feasibility of the approach using central aortic blood pressure waveform and cuff pressure oscillation signals collected from a human subject. We showed that the proposed approach could estimate central aortic blood pressure waveform with accuracy: the root-mean-squared error associated with the central aortic blood pressure waveform was 1.7 mmHg (amounting to 1.6 % of the underlying mean blood pressure) while the errors associated with central aortic systolic and pulse pressures were -0.4 mmHg and -1.5 mmHg (amounting to -0.3 % and -1.4 % of the underlying mean blood pressure).
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Design and Implementation of a Non-invasive and Cuff-less Arterial Blood Pressure Monitoring System
    Anvari, Seyed Mohsen
    Yazdchi, Mohammadreza
    Kayvanpour, Amirhossein
    Mohammad, Seyed
    Nayebpour, Hasan
    Koivisto, Tero
    Tadi, Mojtaba Jafari
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [32] BP-Net: Cuff-less and non-invasive blood pressure estimation via a generic deep convolutional architecture
    Zabihi, Soheil
    Rahimian, Elahe
    Marefat, Fatemeh
    Asif, Amir
    Mohseni, Pedram
    Mohammadi, Arash
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 78
  • [33] Current Developments in Cuff-Free Non-invasive Continuous Blood Pressure Estimation Using Photoplethysmography
    Somen Sarkar
    Sharvan Kumar Pahuja
    Biomedical Materials & Devices, 2024, 2 (2): : 743 - 758
  • [34] Non-invasive cuff-less blood pressure estimation using a hybrid deep learning model
    Yang, Sen
    Zhang, Yaping
    Cho, Siu-Yeung
    Correia, Ricardo
    Morgan, Stephen P.
    OPTICAL AND QUANTUM ELECTRONICS, 2021, 53 (02)
  • [35] 2.8: Invasive Study for Testing Non-Invasive Methods of Aortic Pressure Estimation
    Andrea Guala
    F. Tosello
    D. Leone
    L. Sabia
    F. D’Ascenzo
    T. Crea
    C. Moretti
    F. Gaita
    F. Veglio
    L. Ridolfi
    A. Milan
    Artery Research, 2017, 20 (1) : 52 - 52
  • [36] Non-invasive cuff-less blood pressure estimation using a hybrid deep learning model
    Sen Yang
    Yaping Zhang
    Siu-Yeung Cho
    Ricardo Correia
    Stephen P. Morgan
    Optical and Quantum Electronics, 2021, 53
  • [37] Cascade forest regression algorithm for non-invasive blood pressure estimation using PPG signals
    Zhang, Gengjia
    Shin, Siho
    Jung, Jaehyo
    APPLIED SOFT COMPUTING, 2023, 144
  • [38] Respiratory rate estimation from the oscillometric waveform obtained from a non-invasive cuff-based blood pressure device
    Pimentel, M. A. F.
    Santos, M. D.
    Arteta, C.
    Domingos, J. S.
    Maraci, M. A.
    Clifford, G. D.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3821 - 3824
  • [39] Early Detection of Hemorrhage via Central Pulse Pressure Derived from a Non-Invasive Peripheral Arterial Blood Pressure Waveform
    Zhang, Guanqun
    Ryan, Kathy L.
    Rickards, Caroline A.
    Convertino, Victor A.
    Mukkamala, Ramakrishna
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3116 - 3119
  • [40] The association of aortic pulse wave velocity with non-invasive central and brachial systolic blood pressure
    Cameron, JD
    McGrath, BP
    JOURNAL OF HYPERTENSION, 2004, 22 : S199 - S199