ESTIMATION OF CENTRAL AORTIC BLOOD PRESSURE FROM NON-INVASIVE CUFF PRESSURE OSCILLATION SIGNALS VIA SYSTEM IDENTIFICATION

被引:0
|
作者
Ghasemi, Zahra [1 ]
Kim, Chang-Sei [1 ]
Ginsberg, Eric [2 ]
Duell, John [2 ]
Gupta, Anuj [2 ]
Hahn, Jin-Oh [1 ]
机构
[1] Univ Maryland, College Pk, MD 20742 USA
[2] Univ Maryland, Baltimore, MD 21201 USA
基金
美国国家科学基金会;
关键词
WAVE-FORM; RADIAL TONOMETRY; RECONSTRUCTION; HYPERTENSION; VALIDATION; EXERCISE;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents a model-based system identification approach to estimation of central aortic blood pressure waveform from non-invasive cuff pressure oscillation signals. First, we developed a mathematical model that can reproduce the relationship between central aortic blood pressure waveform and non-invasive cuff pressure oscillation signals at diametric locations by combining models to represent wave propagation in the artery, arterial pressure-volume relationship, and mechanics of the occlusive cuff. Second, we formulated the problem of estimating central aortic blood pressure waveform from non-invasive cuff pressure oscillation signals into a system identification problem. Third, we showed the proof-of-concept of the approach using simulated central aortic blood pressure waveform and cuff pressure oscillation signals. Finally, we illustrated the feasibility of the approach using central aortic blood pressure waveform and cuff pressure oscillation signals collected from a human subject. We showed that the proposed approach could estimate central aortic blood pressure waveform with accuracy: the root-mean-squared error associated with the central aortic blood pressure waveform was 1.7 mmHg (amounting to 1.6 % of the underlying mean blood pressure) while the errors associated with central aortic systolic and pulse pressures were -0.4 mmHg and -1.5 mmHg (amounting to -0.3 % and -1.4 % of the underlying mean blood pressure).
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Complication of a non-invasive blood pressure cuff during prone positioning
    Paul M. Kempen
    Li Meng
    Canadian Journal of Anesthesia, 2006, 53 : 106 - 106
  • [22] A New Non-Invasive Cuff-Less Blood Pressure Sensor
    Tu, Tse-Yi
    Chao, Paul C. -P.
    Lee, Yung-Pin
    2013 IEEE SENSORS, 2013, : 857 - 860
  • [23] Accuracy of the WatchBP Office Central as a Type 2 device for non-invasive estimation of central aortic blood pressure in children and adolescents
    Glenning, Jonathan P.
    Sandhu, Kieran
    Harrington, Hilary A.
    Eastaugh, Lucas
    Lane, Geoffrey K.
    Smolich, Joseph J.
    Mynard, Jonathan P.
    JOURNAL OF HUMAN HYPERTENSION, 2024, 38 (12) : 814 - 820
  • [24] EFFECT OF NON-INVASIVE BLOOD PRESSURE CUFF INFLATION ON INTRA-ARTERIAL BLOOD PRESSURE VALUES
    Sheshadri, V.
    Tiwari, A.
    Nagappa, M.
    Venkatraghavan, L.
    ANESTHESIA AND ANALGESIA, 2016, 122
  • [25] Central Blood Pressure Waves Assessment: A Validation Study of Non-invasive Aortic Pressure Measurement in Human Beings
    Ramiro Sánchez
    Franco Pessana
    Gabriel Lev
    Micaela Mirada
    Oscar Mendiz
    Agustín Ramírez
    Edmundo Cabrera Fischer
    High Blood Pressure & Cardiovascular Prevention, 2020, 27 : 165 - 174
  • [26] Central Blood Pressure Waves Assessment: A Validation Study of Non-Invasive Aortic Pressure Measurement in Human Beings
    Pessana, F. M.
    Lev, G.
    Mirada, M.
    Ramirez, A. J.
    Mendiz, O.
    Fischer, E. I. C.
    2019 GLOBAL MEDICAL ENGINEERING PHYSICS EXCHANGES/PAN AMERICAN HEALTH CARE EXCHANGES (GMEPE/PAHCE), 2019,
  • [27] Central Blood Pressure Waves Assessment: A Validation Study of Non-invasive Aortic Pressure Measurement in Human Beings
    Sanchez, Ramiro
    Pessana, Franco
    Lev, Gabriel
    Mirada, Micaela
    Mendiz, Oscar
    Ramirez, Agustin
    Cabrera Fischer, Edmundo
    HIGH BLOOD PRESSURE & CARDIOVASCULAR PREVENTION, 2020, 27 (02) : 165 - 174
  • [28] Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach
    Chemla, Denis
    Agnoletti, Davide
    Jozwiak, Mathieu
    Zhang, Yi
    Protogerou, Athanase D.
    Millasseau, Sandrine
    Blacher, Jacques
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (08):
  • [29] BP-Net: Cuff-less and non-invasive blood pressure estimation via a generic deep convolutional architecture
    Zabihi, Soheil
    Rahimian, Elahe
    Marefat, Fatemeh
    Asif, Amir
    Mohseni, Pedram
    Mohammadi, Arash
    Biomedical Signal Processing and Control, 2022, 78
  • [30] 12.19: Estimation of Central Systolic Blood Pressure from Arm Cuff Pressure: Comparison with the Sphygmocor System
    S. Brett
    A. Guilcher
    B. Clapp
    P. Chowienczyk
    Artery Research, 2011, 5 (4) : 205 - 205