Signal analysis approach to ultrasonic evaluation of diffusion bond quality

被引:0
|
作者
Thomas, G [1 ]
Chinn, D [1 ]
机构
[1] Univ Calif Lawrence Livermore Natl Lab, Mfg & Mat Engn Dept, Livermore, CA 94550 USA
关键词
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Solid state bonds like the diffusion bond are attractive techniques for joining dissimilar materials since they are not prone to the defects that occur with fusion welding. Ultrasonic methods can detect the presence of totally unbonded regions but have difficulty sensing poor bonded areas where the substrates are in intimate contact. Standard ultrasonic imaging is based on amplitude changes in the signal reflected from the bond interface. Unfortunately, amplitude alone is not sensitive to bond quality. We demonstrated that there is additional information in the ultrasonic signal that correlates with bond quality. In our approach, we interrogated a set of dissimilar diffusion bonded samples with broad band ultrasonic signals. The signals were digitally processed and the characteristics of the signals that corresponded to bond quality were determined. These characteristics or features were processed with pattern recognition algorithms to produce predictions of bond quality. The predicted bond quality was then compared with the destructive measurement to assess the classification capability of the ultrasonic technique.
引用
收藏
页码:536 / 542
页数:7
相关论文
共 50 条
  • [31] AN ULTRASONIC METHOD FOR THE EVALUATION OF MULTIPHASE BINARY DIFFUSION
    RONEN, Z
    ROKHLIN, S
    DARIEL, MP
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1981, 28 (05): : 384 - 384
  • [32] COMPUTER-CONTROLLED ULTRASONIC ADHESIVE BOND EVALUATION
    RAISCH, JW
    ROSE, JL
    MATERIALS EVALUATION, 1979, 37 (06) : 55 - 64
  • [33] Considerations in bond strenght evaluation by ultrasonic guided waves
    1600, American Inst of Physics, Woodbury, NY, USA (96):
  • [34] Ultrasonic evaluation of titanium alloy diffusion bonding
    Nieters, EJ
    Gigliotti, MFX
    Perocchi, LC
    Gilmore, RS
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 15A AND 15B, 1996, 15 : 1313 - 1320
  • [35] On-Line Quality Detection of Ultrasonic Wire Bonding via Refining Analysis of Electrical Signal From Ultrasonic Generator
    Feng, Wuwei
    Meng, Qingfeng
    Xie, Youbo
    Fan, Hong
    JOURNAL OF ELECTRONIC PACKAGING, 2010, 132 (04)
  • [36] Impact of quantization noise on the quality of ultrasonic signal deconvolution
    Renken, MC
    Fortunko, CM
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 15A AND 15B, 1996, 15 : 2081 - 2088
  • [37] Evaluation of Milk Quality by Ultrasonic Technique
    Chen, Chien-Hsing
    Zhang, Li-De
    SENSORS AND MATERIALS, 2019, 31 (02) : 279 - 285
  • [38] ULTRASONIC EVALUATION OF SPOT WELD QUALITY
    ROKHLIN, SI
    ADLER, L
    WELDING JOURNAL, 1985, 64 (07) : S191 - S200
  • [39] On signal processing approach for event detection and compression applied to power quality evaluation
    Ramos, FR
    Ribeiro, MV
    Romano, JMT
    Duque, CA
    10TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, VOLS I AND II, PROCEEDINGS, 2002, : 133 - 138
  • [40] THE EFFECTIVENESS OF DEBT INSURANCE AS A VALID SIGNAL OF BOND QUALITY
    HSUEH, LP
    LIU, YA
    JOURNAL OF RISK AND INSURANCE, 1990, 57 (04) : 691 - 700