Assessment of flow quantification in coronary bypass grafts and coronary arteries with velocity-encoded cine MR imaging

被引:7
|
作者
Kreitner, KF
Voigtländer, T
Wittlinger, T
Dahm, M
Kalden, P
Meyer, J
Thelen, M
机构
[1] Johannes Gutenberg Univ Mainz, Klin & Poliklin Radiol, D-55131 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Med Klin & Poliklin 2, D-6500 Mainz, Germany
[3] Johannes Gutenberg Univ Mainz, Klin Herz Thorax & Gafasschirurg, D-6500 Mainz, Germany
来源
RADIOLOGE | 2000年 / 40卷 / 02期
关键词
MR imaging; flow quantification; coronary artery; coronary bypass grafts;
D O I
10.1007/s001170050023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate accuracy of velocity encoded cine MR imaging for determination of blood Row in coronary arteries and coronary bypass grafts. Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For Row measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and Row measurements using velocity-encoded MR imaging (r=0.74,p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean Row in coronary arteries was reduced in severly stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver variability were 10.5 and 15% (coronary bypass grafts),and 12.3 and 15.8% (coronary arteries),respectively. Conclusions: Velocity-encoded MR imaging enables determination of Row in coronary artery bypass grafts and coronary arteries. Future developments should aim at the improvement of spatial and temporal resolution of the method.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 50 条
  • [41] Risk factor of radiation pneumonitis - Assessment with velocity-encoded cine magnetic resonance imaging of pulmonary artery
    Muryama, S
    Akamine, T
    Sakai, S
    Oshiro, Y
    Kakinohana, Y
    Soeda, H
    Toita, T
    Adachi, G
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (02) : 204 - 208
  • [43] Pulmonary regurgitation after repair of tetralogy of Fallot: Quantification with velocity-encoded cine MRI
    Reddy, GP
    Araoz, PA
    Akbari, H
    Varaprasathan, G
    Tarnoff, H
    Higgins, CB
    RADIOLOGY, 2002, 225 : 528 - 529
  • [44] RIGHT AND LEFT-VENTRICULAR STROKE VOLUME MEASUREMENTS WITH VELOCITY-ENCODED CINE MR IMAGING - INVITRO AND INVIVO VALIDATION
    KONDO, C
    CAPUTO, GR
    SEMELKA, R
    FOSTER, E
    SHIMAKAWA, A
    HIGGINS, CB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) : 9 - 16
  • [45] THE ASSESSMENT OF CORONARY-ARTERY BYPASS GRAFTS BY MAGNETIC-RESONANCE-IMAGING WITH VELOCITY MAPPING
    UNDERWOOD, SR
    FIRMIN, DN
    KLIPSTEIN, RH
    REES, RSO
    LONGMORE, DB
    BRITISH HEART JOURNAL, 1987, 57 (01): : 93 - 93
  • [46] RIGHT AND LEFT LUNG PERFUSION - INVITRO AND INVIVO VALIDATION WITH OBLIQUE-ANGLE, VELOCITY-ENCODED CINE MR IMAGING
    CAPUTO, GR
    KONDO, C
    MASUI, T
    GERACI, SJ
    FOSTER, E
    OSULLIVAN, MM
    HIGGINS, CB
    RADIOLOGY, 1991, 180 (03) : 693 - 698
  • [47] Assessment of Pulmonary Arterial Pressure in Children with Congenital Heart Disease by Velocity-Encoded Cine Magnetic Resonance Imaging
    Sugimoto, Masaya
    Kajino, Hiroki
    Kajihama, Aya
    Nakau, Kouichi
    Azuma, Hiroshi
    CIRCULATION, 2012, 126 (21)
  • [48] Assessment of coronary artery bypass grafts by magnetic resonance imaging
    Stauder, N. I.
    Klumpp, B.
    Stauder, H.
    Blumenstock, G.
    Fenchel, M.
    Kuettner, A.
    Claussen, C. D.
    Miller, S.
    BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (960): : 975 - 983
  • [49] Assessment of coronary bypass grafts by intraoperative flow reserve measurements
    Walpoth, BH
    Bosshard, A
    Neidhart, P
    Kipfer, B
    Berdat, P
    Hess, OM
    Althaus, U
    Carrel, T
    ANESTHESIOLOGY, 1998, 89 (3A) : U280 - U280
  • [50] Assessment of Pulmonary Arterial Pressure by Velocity-Encoded Cine Magnetic Resonance Imaging in Children With Congenital Heart Disease
    Sugimoto, Masaya
    Kajino, Hiroki
    Kajihama, Aya
    Nakau, Kouichi
    Murakami, Noboru
    Azuma, Hiroshi
    CIRCULATION JOURNAL, 2013, 77 (12) : 3015 - 3022