Assessment of flow quantification in coronary bypass grafts and coronary arteries with velocity-encoded cine MR imaging

被引:7
|
作者
Kreitner, KF
Voigtländer, T
Wittlinger, T
Dahm, M
Kalden, P
Meyer, J
Thelen, M
机构
[1] Johannes Gutenberg Univ Mainz, Klin & Poliklin Radiol, D-55131 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Med Klin & Poliklin 2, D-6500 Mainz, Germany
[3] Johannes Gutenberg Univ Mainz, Klin Herz Thorax & Gafasschirurg, D-6500 Mainz, Germany
来源
RADIOLOGE | 2000年 / 40卷 / 02期
关键词
MR imaging; flow quantification; coronary artery; coronary bypass grafts;
D O I
10.1007/s001170050023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate accuracy of velocity encoded cine MR imaging for determination of blood Row in coronary arteries and coronary bypass grafts. Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For Row measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and Row measurements using velocity-encoded MR imaging (r=0.74,p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean Row in coronary arteries was reduced in severly stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver variability were 10.5 and 15% (coronary bypass grafts),and 12.3 and 15.8% (coronary arteries),respectively. Conclusions: Velocity-encoded MR imaging enables determination of Row in coronary artery bypass grafts and coronary arteries. Future developments should aim at the improvement of spatial and temporal resolution of the method.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 50 条
  • [31] SEVERITY OF AORTIC REGURGITATION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH VELOCITY-ENCODED CINE MR-IMAGING
    DULCE, MC
    MOSTBECK, GH
    OSULLIVAN, M
    CHEITLIN, M
    CAPUTO, GR
    HIGGINS, CB
    RADIOLOGY, 1992, 185 (01) : 235 - 240
  • [32] AORTIC-VALVE PRESSURE-GRADIENTS IN PATIENTS WITH AORTIC-VALVE STENOSIS - QUANTIFICATION WITH VELOCITY-ENCODED CINE MR IMAGING
    EICHENBERGER, AC
    JENNI, R
    VONSCHULTHESS, GK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) : 971 - 977
  • [33] Arterial, Venous, and Cerebrospinal Fluid Flow: Simultaneous Assessment with Bayesian Multipoint Velocity-encoded MR Imaging
    Knobloch, Verena
    Binter, Christian
    Kurtcuoglu, Vartan
    Kozerke, Sebastian
    RADIOLOGY, 2014, 270 (02) : 566 - 573
  • [34] BYPASS GRAFTS TO PATENT CORONARY ARTERIES
    Campos, Enrique Padilla
    Malik, Rahul
    Danciu, Sorin
    Haery, Cameron
    Beall, Allan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 2257 - 2257
  • [35] In Vivo MR Angiography and Velocity Measurement in Mice Coronary Arteries at 9.4 T: Assessment of Coronary Flow Velocity Reserve
    Cochet, Hubert
    Montaudon, Michel
    Laurent, Francois
    Calmettes, Guillaume
    Franconi, Jean-Michel
    Miraux, Sylvain
    Thiaudiere, Eric
    Parzy, Elodie
    RADIOLOGY, 2010, 254 (02) : 441 - 448
  • [36] Assessment of patency in bypass grafts to the left anterior descending coronary artery: Correlation of MR imaging with coronary angiography
    Schmidt, HC
    Voigtlaender, T
    Kreitner, KF
    Wittlinger, T
    Meyer, J
    Thelen, M
    RADIOLOGY, 1996, 201 : 787 - 787
  • [37] CORONARY-ARTERY BYPASS GRAFTS - VISUALIZATION WITH MR IMAGING
    GOMES, AS
    LOIS, JF
    DRINKWATER, DC
    CORDAY, SR
    RADIOLOGY, 1987, 162 (01) : 175 - 179
  • [38] QUANTIFICATION OF LEFT-TO-RIGHT ATRIAL SHUNTS WITH VELOCITY-ENCODED CINE NUCLEAR-MAGNETIC-RESONANCE IMAGING
    BRENNER, LD
    CAPUTO, GR
    MOSTBECK, G
    STEIMAN, D
    DULCE, M
    CHEITLIN, MD
    OSULLIVAN, M
    HIGGINS, CB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (05) : 1246 - 1250
  • [39] COMPARISON OF VELOCITY-ENCODED MR IMAGING AND FLUID DYNAMIC MODELING OF STEADY AND DISTURBED FLOW
    SUN, Y
    HEARSHEN, DO
    RANKIN, GW
    HAGGAR, AM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (04): : 443 - 452
  • [40] ESTIMATION OF FLOW IN VEIN OF GALEN MALFORMATIONS BY USING VELOCITY-ENCODED MR-IMAGING
    POSKITT, KJ
    CULHAM, JG
    RADIOLOGY, 1995, 197 : 307 - 307