Assessment of flow quantification in coronary bypass grafts and coronary arteries with velocity-encoded cine MR imaging

被引:7
|
作者
Kreitner, KF
Voigtländer, T
Wittlinger, T
Dahm, M
Kalden, P
Meyer, J
Thelen, M
机构
[1] Johannes Gutenberg Univ Mainz, Klin & Poliklin Radiol, D-55131 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Med Klin & Poliklin 2, D-6500 Mainz, Germany
[3] Johannes Gutenberg Univ Mainz, Klin Herz Thorax & Gafasschirurg, D-6500 Mainz, Germany
来源
RADIOLOGE | 2000年 / 40卷 / 02期
关键词
MR imaging; flow quantification; coronary artery; coronary bypass grafts;
D O I
10.1007/s001170050023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate accuracy of velocity encoded cine MR imaging for determination of blood Row in coronary arteries and coronary bypass grafts. Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For Row measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and Row measurements using velocity-encoded MR imaging (r=0.74,p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean Row in coronary arteries was reduced in severly stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver variability were 10.5 and 15% (coronary bypass grafts),and 12.3 and 15.8% (coronary arteries),respectively. Conclusions: Velocity-encoded MR imaging enables determination of Row in coronary artery bypass grafts and coronary arteries. Future developments should aim at the improvement of spatial and temporal resolution of the method.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 50 条
  • [1] Flussquantifizierung in Koronar- und Bypass- gefäßen mit der MR-PhasenkontrasttechnikAssessment of flow quantification in coronary bypass grafts and coronary arteries with velocity-encoded cine MR imaging
    K.-F. Kreitner
    T. Voigtländer
    T. Wittlinger
    M. Dahm
    P. Kalden
    J. Meyer
    M. Thelen
    Der Radiologe, 2000, 40 : 143 - 149
  • [2] Quantification of coronary artery volume flow rate using fast velocity-encoded cine MR imaging
    Sakuma, H
    Saeed, M
    Takeda, K
    Wendland, MF
    Schwitter, J
    Szolar, DH
    Derugin, N
    Shimakawa, A
    Foo, TKF
    Higgins, CB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) : 1363 - 1367
  • [3] Coronary sinus flow measurement by velocity-encoded cine MR imaging: Validation by Doppler flow probes
    Lund, GK
    Wendland, MF
    Shimakawa, A
    Higgins, B
    Saeed, M
    CIRCULATION, 1999, 100 (18) : 457 - 457
  • [4] Coronary flow reserve: Noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging
    Sakuma, H
    Blake, LM
    Amidon, TM
    OSullivan, M
    Szolar, DH
    Furber, AP
    Bernstein, MA
    Foo, TKF
    Higgins, CB
    RADIOLOGY, 1996, 198 (03) : 745 - 750
  • [5] Quantification of flow dynamics in congenital heart disease: Applications of velocity-encoded cine MR imaging
    Varaprasathan, GA
    Araoz, PA
    Higgins, CB
    Reddy, GP
    RADIOGRAPHICS, 2002, 22 (04) : 895 - 905
  • [6] Coronary sinus flow measurement by means of velocity-encoded cine MR imaging:: Validation by using flow probes in dogs
    Lund, GK
    Wendland, MF
    Shimakawa, A
    Arheden, H
    Ståhlberg, F
    Higgins, CB
    Saeed, M
    RADIOLOGY, 2000, 217 (02) : 487 - 493
  • [7] Assessment of coronary flow reserve using fast velocity-encoded cine MR imaging: Validation study using positron emission tomography
    Sakuma, H
    Koskenvuo, JW
    Niemi, P
    Kawada, N
    Toikka, JO
    Knuuti, J
    Laine, H
    Saraste, M
    Kormano, M
    Hartiala, JJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (04) : 1029 - 1033
  • [8] PULMONARY-HYPERTENSION - PULMONARY FLOW QUANTIFICATION AND FLOW PROFILE ANALYSIS WITH VELOCITY-ENCODED CINE MR IMAGING
    KONDO, C
    CAPUTO, GR
    MASUI, T
    FOSTER, E
    OSULLIVAN, M
    STULBARG, MS
    GOLDEN, J
    CATTERJEE, K
    HIGGINS, CB
    RADIOLOGY, 1992, 183 (03) : 751 - 758
  • [9] QUANTIFICATION OF AORTIC-STENOSIS WITH VELOCITY-ENCODED CINE MR
    EICHENBERGER, AC
    JENNI, R
    VONSCHULTHESS, GK
    RADIOLOGY, 1992, 185 : 276 - 276
  • [10] Measurement of phasic coronary flow with velocity encoded cine MR imaging and respiratory gating
    Post, JC
    Hofman, MB
    Galjee, MA
    vanRossum, AC
    CIRCULATION, 1996, 94 (08) : 711 - 711