Dopamine transporter SPECT using fast kinetic ligands:: 123I-FP-β-CIT versus 99mTc-TRODAT-1

被引:46
|
作者
Van Laere, K
De Ceuninck, L
Dom, R
Van den Eynden, J
Vanbilloen, H
Cleynhens, J
Dupont, P
Bormans, G
Verbruggen, A
Mortelmans, L
机构
[1] Leuven Univ Hosp, Div Nucl Med, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, B-3000 Louvain, Belgium
[3] Leuven Univ Hosp, Dept Neurol, Louvain, Belgium
[4] Leuven Univ Hosp, Dept Radiopharmaceut Chem, Louvain, Belgium
关键词
FP-beta-CIT; TRODAT-1; idiopathic parkinsonism; Parkinson's disease; differential diagnosis;
D O I
10.1007/s00259-004-1480-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A comparative study was carried out on two promising presynaptic dopamine transporter single-photon emission tomography (SPECT) radioligands with a fast pharmacokinetic profile, I-123-FP-beta-CIT (FP) and Tc-99m-TRODAT-1 (TR), in order to assess their differential diagnostic power in early parkinsonism and their sensitivity for detection of disease progression. This cross-sectional study was conducted on 96 patients with early-stage parkinsonism referred in a tertiary clinical setting. Mean disease duration was 2.0 +/- 1.3 years, and patients had a modified Hoehn and Yahr (H&Y) stage of 1-2 (average 1.2). Forty-seven patients received TR, and 49 received FP. In both groups, ten patients with normal presynaptic function were included as a control population; all other patients were clinically diagnosed as having idiopathic Parkinson's disease. Groups were matched for gender, age, disease duration and modified H&Y stage. Triple-head gamma camera SPECT was analysed using a serniquantitative index of transporter binding (BI). Discriminant analysis with cross-validation resulted in a maximal classification accuracy for FP of 93% (sensitivity 95% and specificity 86%) for the contralateral putamen BI. For TR, the corresponding values were 87% accuracy, 92% sensitivity and 70% specificity. For FP, disease duration was correlated with both the putamen BI (-8.8%/year, rho=-0.41, P=0.025) and the putamen/caudate ratio (-7.4%/year, rho=-0.51, P=0.004), but for TR no significant correlation was found (all P values >0.5). In conclusion, both FP and TR show high sensitivity in a clinically relevant setting, but FP has superior accuracy for early differential diagnosis of idiopathic parkinsonism and non-degenerative extrapyran-tidal disorders, as well as better sensitivity for disease follow-up.
引用
收藏
页码:1119 / 1127
页数:9
相关论文
共 50 条
  • [1] Dopamine transporter SPECT using fast kinetic ligands: 123I-FP-β-CIT versus 99mTc-TRODAT-1
    K. Van Laere
    L. De Ceuninck
    R. Dom
    J. Van den Eynden
    H. Vanbilloen
    J. Cleynhens
    P. Dupont
    G. Bormans
    A. Verbruggen
    L. Mortelmans
    European Journal of Nuclear Medicine and Molecular Imaging, 2004, 31 : 1119 - 1127
  • [2] Dopamin transporter SPECT:: 123I-FP-beta-CIT vs. 99mTc-TRODAT-1
    Besenyi, Z.
    Argyelan, M.
    Szabo, Z.
    Janka, Z.
    Pavics, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S258 - S259
  • [3] Dopamine Transporter Imaging Using 99mTc-TRODAT-1 SPECT in Parkinson's Disease
    Bor-Seng-Shu, Edson
    Felicio, Andre C.
    Braga-Neto, Pedro
    Batista, Ilza Rosa
    Paiva, Wellingson Silva
    de Andrade, Daniel Ciampi
    Teixeira, Manoel Jacobsen
    Franco de Andrade, Luiz Augusto
    Povoas Barsottini, Orlando Graziani
    Shih, Ming Chi
    Bressan, Rodrigo A.
    Ferraz, Henrique Ballalai
    MEDICAL SCIENCE MONITOR, 2014, 20 : 1413 - 1418
  • [4] Comparable investigation in dopamine transporters with 99mTc-TRODAT-1 and 131I-FP-CIT SPECT in Parkinson’s disease patients
    LIU Congjin1 LIU Xingdang1* ZHANG Guangming1 LI Ding1 WANG Jian2 YANG Liqin2 JIANG Yuping2 (1 Department of Nuclear Medicine
    2 Department of Neurology
    NuclearScienceandTechniques, 2007, (04) : 232 - 236
  • [5] An Incidental Finding of CerebralMeningioma on 99mTc-TRODAT-1 Dopamine Transporter SPECT/CT
    Chiu, Yu-Li
    Hu, Chin
    Li, Jie-Yuan
    Weng, Mei-Jui
    Lin, Wen-Chun
    Peng, Nan-Jing
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (09) : 899 - 900
  • [6] 99mTc-TRODAT-1 Micro-SPECT study on dopamine transporter in myopia retina
    Zhao, Juan
    Qu, Xiaomei
    Huang, Jia
    Qi, Yujin
    Dai, Qiusheng
    Zhang, Xuezhu
    Zhou, Wei
    Hu, Weiqing
    Liu, Xingdang
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [7] Feasibility of 99mTc-TRODAT-1 Micro-SPECT imaging of dopamine transporter in animal retinas
    Zhao Juan
    Qi Yujin
    Dai Qiusheng
    Zhang Xuezhu
    Qu Xiaomei
    Huang Jia
    Liu Xingdang
    NUCLEAR SCIENCE AND TECHNIQUES, 2008, 19 (02) : 105 - 108
  • [8] Feasibility of 99mTc-TRODAT-1 Micro-SPECT imaging of dopamine transporter in animal retinas
    ZHAO Juan~1 QIYujin~2 DAI Qiusheng~2 ZHANG Xuezhu~2 QU Xiaomei~3 HUANG Jia~3 LIU Xingdang~(1
    NuclearScienceandTechniques, 2008, (02) : 105 - 108
  • [9] Dopamine transporter availability in medication free and in bupropion treated depression:: A 99mTc-TRODAT-1 SPECT study
    Argyelán, M
    Szabó, Z
    Kanyó, B
    Tanács, A
    Kovács, Z
    Janka, Z
    Pávics, L
    JOURNAL OF AFFECTIVE DISORDERS, 2005, 89 (1-3) : 115 - 123
  • [10] Dopamine transporter levels in detoxified heroin dependent subjects: A 99mTc-TRODAT-1 SPECT imaging study
    Yuan, J.
    Liu, X.
    Han, M.
    Lv, R.
    Wang, Y.
    Zhang, G.
    Li, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S226 - S226