Dopamine transporter SPECT using fast kinetic ligands:: 123I-FP-β-CIT versus 99mTc-TRODAT-1

被引:46
|
作者
Van Laere, K
De Ceuninck, L
Dom, R
Van den Eynden, J
Vanbilloen, H
Cleynhens, J
Dupont, P
Bormans, G
Verbruggen, A
Mortelmans, L
机构
[1] Leuven Univ Hosp, Div Nucl Med, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, B-3000 Louvain, Belgium
[3] Leuven Univ Hosp, Dept Neurol, Louvain, Belgium
[4] Leuven Univ Hosp, Dept Radiopharmaceut Chem, Louvain, Belgium
关键词
FP-beta-CIT; TRODAT-1; idiopathic parkinsonism; Parkinson's disease; differential diagnosis;
D O I
10.1007/s00259-004-1480-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A comparative study was carried out on two promising presynaptic dopamine transporter single-photon emission tomography (SPECT) radioligands with a fast pharmacokinetic profile, I-123-FP-beta-CIT (FP) and Tc-99m-TRODAT-1 (TR), in order to assess their differential diagnostic power in early parkinsonism and their sensitivity for detection of disease progression. This cross-sectional study was conducted on 96 patients with early-stage parkinsonism referred in a tertiary clinical setting. Mean disease duration was 2.0 +/- 1.3 years, and patients had a modified Hoehn and Yahr (H&Y) stage of 1-2 (average 1.2). Forty-seven patients received TR, and 49 received FP. In both groups, ten patients with normal presynaptic function were included as a control population; all other patients were clinically diagnosed as having idiopathic Parkinson's disease. Groups were matched for gender, age, disease duration and modified H&Y stage. Triple-head gamma camera SPECT was analysed using a serniquantitative index of transporter binding (BI). Discriminant analysis with cross-validation resulted in a maximal classification accuracy for FP of 93% (sensitivity 95% and specificity 86%) for the contralateral putamen BI. For TR, the corresponding values were 87% accuracy, 92% sensitivity and 70% specificity. For FP, disease duration was correlated with both the putamen BI (-8.8%/year, rho=-0.41, P=0.025) and the putamen/caudate ratio (-7.4%/year, rho=-0.51, P=0.004), but for TR no significant correlation was found (all P values >0.5). In conclusion, both FP and TR show high sensitivity in a clinically relevant setting, but FP has superior accuracy for early differential diagnosis of idiopathic parkinsonism and non-degenerative extrapyran-tidal disorders, as well as better sensitivity for disease follow-up.
引用
收藏
页码:1119 / 1127
页数:9
相关论文
共 50 条
  • [41] Technical factors affecting 123I-FP-CIT presynaptic dopamine transporter (DaT) SPECT studies
    Nichols, Kenneth
    Tomas, Maria-Bernadette
    Palestro, Christopher
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [42] SPECT with dopamine transporter-specific radiotracer 123I-FP-CIT in benign essential blepharospasm
    Roselli, F.
    Pisciotta, N. M.
    Liuzzi, D.
    Martino, D.
    Livrea, P.
    Rubini, G.
    Berardelli, A.
    Defazio, G.
    MOVEMENT DISORDERS, 2009, 24 : S84 - S85
  • [43] Optimizing 123I-FP-CIT presynaptic dopamine transporter (DAT) SPECT reconstruction by phantom simulations
    Nichols, Kenneth
    Tomas, Maria
    Rivera, Leonardo
    Leveque, Fritzgerald
    Palestro, Christopher
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [44] Technical factors affecting 123I-FP-CIT presynaptic dopamine transporter (DaT) SPECT studies
    Nichols, Kenneth
    Tomas, Maria-Bernadette
    Palestro, Christopher
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [45] Smoking and striatal dopamine transporter availability in healthy volunteers using [123I]FP-CIT (DaTSCAN) and SPECT
    Thomsen, Gerda
    Jensen, Peter
    Ziebell, Morten
    Holst, Klaus
    Knudsen, Gitte
    Pinborg, Lars
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [46] Correlation of response to subthalamic deep brain stimulation in Parkinson's disease patients with striatal dopamine transporter density on 99mtc-TRODAT-1 SPECT
    Ghaedian, Tahereh
    Razmkon, Ali
    Kalhor, Leila
    Ostovan, Vahid Reza
    Yousefi, Omid
    Rezaei, Raziyeh
    Hossein-Tehrani, Mohammad Reza
    Rakhsha, Abbas
    NEUROLOGICAL RESEARCH, 2023, 45 (06) : 505 - 509
  • [47] Reference Values for Dopamine Transporter Imaging With 99mTc-TRODAT-1 in Healthy Subjects and Parkinson's Disease Patients
    Pitella, Felipe Arriva
    Trevisan, Ana Carolina
    Alexandre-Santos, Leonardo
    Kato, Mery
    Brito, Manuelina Mariana Capellari Macruz
    Tumas, Vitor
    Wichert-Ana, Lauro
    CLINICAL NUCLEAR MEDICINE, 2022, 47 (09) : 794 - 799
  • [48] A New Era of Clinical Dopamine Transporter Imaging Using I-123-FP-CIT
    Park, Eunkyung
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2012, 40 (04) : 222 - 228
  • [49] Combined [123I]FP-CIT SPECT and 99mTc-HMPAO SPECT for the diagnosis of dementia with Lewy bodies
    Mendonca Silva, N. M.
    Cunha, M. J.
    Januario, C.
    PARKINSONISM & RELATED DISORDERS, 2007, 13 : S155 - S155
  • [50] SPECT Studies with the 123I-labeled Dopamine Transporter Ligands FP-CIT (DaTSCANTM) DGN Recommendation for Action (S1 Guideline)
    Tatsch, Klaus
    Buchert, Ralph
    Bartenstein, Peter
    Barthel, Henryk
    Boecker, Henning
    Brust, Peter
    Drzezga, Alexander
    la Fougere, Christian
    Gruender, Gerhard
    Gruenwald, Frank
    Krause, Bernd-J.
    Kuwert, Torsten
    Langen, Karl-Josef
    Rominger, Axel
    Sabri, Osama
    Schreckenberger, Mathias
    Meyer, Philipp T.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2019, 58 (01): : 5 - 14