Comparison of Partially Threaded and Fully Threaded 4mm Cancellous Screws in Fixation of Medial Malleolar Fractures

被引:2
|
作者
Sayyed-Hosseinian, Sayyed-Hadi [1 ,2 ]
Bagheri, Farshid [1 ,2 ]
Ebrahimzadeh, Mohammad Hosein [1 ,3 ]
Moradi, Ali [1 ,3 ]
Golshan, Sogol [1 ,2 ]
机构
[1] Mashhad Univ Med Sci, Shahid Kamyab Hosp, Mashhad, Razavi Khorasan, Iran
[2] Mashhad Univ Med Sci, Shahid Kamyab Hosp, Orthoped Res Ctr, Mashhad, Razavi Khorasan, Iran
[3] Mashhad Univ Med Sci, Orthoped Res Ctr, Ghaem Hosp, Mashhad, Razavi Khorasan, Iran
来源
关键词
Ankle fracture; Fracture fixation; Medial malleolus; Screw; ANKLE FRACTURES; STRENGTH;
D O I
10.22038/abjs.2020.46112.2263
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Several devices have been described for fixation of displaced medial malleolar fractures. Fully threaded cancellous screws engaging the bone may provide advantages compared to partially threaded screws. This study was designed to compare the clinical results of fully and partially threaded 4 millimeter cancellous screws in fixation of medial malleolar fractures. Methods: In a randomized clinical trial study 44 patients with displaced closed medial malleolar fractures were randomly divided into two groups. Two fully threaded four millimeter cancellous screws were used for fracture stabilization (FT group) in the first group, while, the second group was operated by use of two partially threaded four millimeter cancellous screws (PT group). The clinical outcomes and complications were compared in two groups at one year follow up. Results: Nineteen patients in FT group and 21 in PT group were present at final follow up. Nonunion was not developed in either group but two cases (9%) of delayed union occurred in PT group. The rate of postoperative infection and symptomatic hardware were not statistically different. Functional assessment using AOFAS, MOXFQ and VAS scores showed no significant difference between the two groups. Conclusion: Both fully and partially threaded 4 mm cancellous screws can be considered as acceptable devices for the fixation of medial malleolar fractures with good and comparable clinical results.
引用
收藏
页码:710 / 715
页数:6
相关论文
共 50 条
  • [41] Is just one screw really enough? Single- versus double-screw in the medial malleolus in supination-external rotation ankle fractures: A comparative biomechanical study using partially threaded cancellous screws
    Giordano, Vincenzo
    Rodrigues, Aliny
    Voelcker, Luiza
    Alves, Gabriel
    Pires, Robinson Esteves
    Freitas, Anderson
    Belangero, William Dias
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (02):
  • [42] The limitations of fully threaded screws in isolated percutaneous transarticular screw fixation of C1/C2
    Leon-Gordian Koepke
    Annika Heuer
    Martin Stangenberg
    Marc Dreimann
    Jörg Beyerlein
    Christian Schaefer
    Lennart Viezens
    Scientific Reports, 12
  • [43] The limitations of fully threaded screws in isolated percutaneous transarticular screw fixation of C1/C2
    Koepke, Leon-Gordian
    Heuer, Annika
    Stangenberg, Martin
    Dreimann, Marc
    Beyerlein, Joerg
    Schaefer, Christian
    Viezens, Lennart
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [44] Improving Outcomes with Sequential Fixation Using Long-Threaded Screws for Valgus-Impacted Femoral Neck Fractures
    Koh, Jeong-Hyun
    Sakong, Seungyeob
    Cho, Won-Tae
    Lim, Sumin
    Song, Hyung Keun
    MEDICINA-LITHUANIA, 2025, 61 (01):
  • [45] Biomechanical Comparison of Locking Plate and Cancellous Screw Techniques in Medial Malleolar Fractures: A Finite Element Analysis
    Jiang, Dajun
    Zhan, Shi
    Wang, Qing
    Ling, Ming
    Hu, Hai
    Jia, Weitao
    JOURNAL OF FOOT & ANKLE SURGERY, 2019, 58 (06): : 1138 - 1144
  • [46] THE FIXATION OF FRACTURES OF THE UPPER FEMUR AND HIP WITH THREADED, HEXAGON-HEADED, STAINLESS-STEEL SCREWS OF FIXED LENGTH
    HARMON, PH
    JOURNAL OF BONE AND JOINT SURGERY, 1945, 27 (01): : 128 - 137
  • [47] Biomechanical properties of a posterior fully threaded positioning screw for cannulated screw fixation of displaced neck of femur fractures
    Schaefer, Thomas K.
    Spross, Christian
    Stoffel, Karl K.
    Yates, Piers J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (11): : 2130 - 2133
  • [48] A comparative study of early functional outcomes in undisplaced neck of femur fracture treated with partially threaded and fully threaded cannulated screw fixation in patients above 60 years age
    Awais, Muhammad Zarak
    Salik, Eman
    Bokhari, Syed Hassan Raza
    Iqbal, Muhammad Tahir
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2023, 39 (05) : 1531 - 1534
  • [49] FIXATION OF DISPLACED FEMORAL-NECK FRACTURES - A COMPARISON BETWEEN SLIDING SCREW PLATE AND 4 CANCELLOUS BONE SCREWS
    MADSEN, F
    LINDE, F
    ANDERSEN, E
    BIRKE, H
    HVASS, I
    POULSEN, TD
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (03): : 212 - 216
  • [50] Decreased complications but a distinctive fixation loosening mechanism of fully threaded headless cannulated screw fixation for femoral neck fractures in young adults
    Sun, Hui
    Shu, Lin-Yuan
    Sherrier, Matthew C.
    Zhu, Yi
    Liu, Jing-Wen
    Zhang, Wei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)