Decreased complications but a distinctive fixation loosening mechanism of fully threaded headless cannulated screw fixation for femoral neck fractures in young adults

被引:24
|
作者
Sun, Hui [1 ]
Shu, Lin-Yuan [2 ]
Sherrier, Matthew C. [3 ]
Zhu, Yi [1 ]
Liu, Jing-Wen [1 ]
Zhang, Wei [1 ]
机构
[1] Shanghai Jiao Tong Univ Affiliated Peoples Hosp 6, Dept Orthopaed Surg, 600 YiShan Rd, Shanghai 200233, Peoples R China
[2] Shanghai Jiao Tong Univ Affiliated Peoples Hosp 6, Dept Emergency Med, 600 YiShan Rd, Shanghai 200233, Peoples R China
[3] Univ Pittsburgh, Dept Phys Med & Rehabil, Med Ctr, Pittsburgh, PA 15219 USA
关键词
Femoral neck fracture; Internal fixation; Fully threaded headless cannulated screws; Complication; Fixation failure;
D O I
10.1186/s13018-021-02335-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Despite being a commonly encountered injury in orthopedic practice, controversy surrounds the methods of optimal internal fixation for femoral neck fractures (FNF) in young patients. The objective of the present study is to compare complication rates and failure mechanisms for surgical fixation of FNF using fully threaded headless cannulated screws (FTHCS) versus partial threaded cannulated screws (PTS) in young adults. Methods A total of 75 patients (18-65 years old) with FNF were prospectively treated with close reduction and internal fixation using three parallel FTHCS and compared to a historical control case-matched group (75 patients) with FNF treated by PTS fixation. After 2 years follow-up, rates of fixation failure (including varus collapse, fracture displacement, and femoral neck shortening), nonunion, and avascular necrosis of the femoral head (ANFH) were compared between the two cohorts. The demographic, follow-up information, and radiological images were assessed by independent blinded investigators. Results Patient demographics and fracture patterns were similar in the two patient groups. The overall fixation failure rates were 8% (6/75) in the FTHCS cohort, which was significantly lower than the 25.3% (19/75) seen in the PTS group. Rates of nonunion and ANFH were significantly lower in the FTHCS group when compared to the PTS control group. When stratified by injury severity (high-energy vs. low-energy fractures), the rate of fixation failure was significant lower with the use of FTHCS when compared with PTS for high-energy fractures while there was no difference in the rates of nonunion or ANFH for high or low-energy fracture patterns. Unique to the FTHCS cohort was an atypical screw migration pattern with varus collapse (6/75, 8%). Conclusions The results show that FTHCS fixation could significantly reduce the complication rate of young patients with FNF, especially in high-energy fracture patterns (Garden III-IV, Pauwels III, or vertical of the neck axis (VN) angle >= 15 degrees). There was also confirmation that the modes of fixation loosening in the FTCHS group, including screw "medial migration" and superior cutout, were different from the screw withdrawal pattern seen in the PTS cohort.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Decreased complications but a distinctive fixation loosening mechanism of fully threaded headless cannulated screw fixation for femoral neck fractures in young adults
    Hui Sun
    Lin-Yuan Shu
    Matthew C. Sherrier
    Yi Zhu
    Jing-Wen Liu
    Wei Zhang
    Journal of Orthopaedic Surgery and Research, 16
  • [2] Multiple cannulated screw fixation of young femoral neck fractures
    Kim, Joo Yong
    Kong, Gyu Min
    Park, Dae Hyun
    Kim, Dae Yoo
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2015, 31 (06) : 1517 - 1520
  • [3] Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults
    Kai-xuan Yuan
    Fan Yang
    Kai Fu
    Dao-yu Zhu
    Chen-yi Jiang
    Dong-xu Jin
    Ze-hao Wang
    Xiao-yuan Peng
    You-Shui Gao
    Peng-bo Luo
    Journal of Orthopaedic Surgery and Research, 17
  • [4] Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults
    Yuan, Kai-xuan
    Yang, Fan
    Fu, Kai
    Zhu, Dao-yu
    Jiang, Chen-yi
    Jin, Dong-xu
    Wang, Ze-hao
    Peng, Xiao-yuan
    Gao, You-Shui
    Luo, Peng-bo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [5] Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures
    Yoram A. Weil
    Feras Qawasmi
    Meir Liebergall
    Rami Mosheiff
    Amal Khoury
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 661 - 667
  • [6] Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures
    Weil, Yoram A.
    Qawasmi, Feras
    Liebergall, Meir
    Mosheiff, Rami
    Khoury, Amal
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (05) : 661 - 667
  • [7] The value of washers in cannulated screw fixation of femoral neck fractures
    Zlowodzki, M
    Weening, B
    Petrisor, B
    Bhandari, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (04): : 969 - 975
  • [8] Does fully-threaded Headless Compression Screw provide a length-stable fixation in undisplaced femoral neck fractures?
    Chiang, Ming-Hung
    Wang, Chun-Liang
    Fu, Shau-Huai
    Hung, Chih-Chien
    Yang, Rong-Sen
    ASIAN JOURNAL OF SURGERY, 2019, 42 (01) : 320 - 325
  • [9] Factors that influence the complications and outcomes of femoral neck fractures treated by cannulated screw fixation
    Nikolai Ramadanov
    Ionel Toma
    Harald Herkner
    Roman Klein
    Wilhelm Behringer
    Gerrit Matthes
    Scientific Reports, 10
  • [10] Factors that influence the complications and outcomes of femoral neck fractures treated by cannulated screw fixation
    Ramadanov, Nikolai
    Toma, Ionel
    Herkner, Harald
    Klein, Roman
    Behringer, Wilhelm
    Matthes, Gerrit
    SCIENTIFIC REPORTS, 2020, 10 (01)