Injectable intraocular telescope: Pilot study

被引:19
|
作者
Qureshi, Muhammad A. [1 ,2 ]
Robbie, Scott J. [2 ]
Tabernero, Juan [3 ]
Artal, Pablo
机构
[1] London Eye Hosp, London W1G 9PB, England
[2] London Eye Hosp Pharma, London, England
[3] Univ Murcia, Lab Opt, Murcia, Spain
来源
关键词
MACULAR DEGENERATION; SURGERY; DISEASE; SYSTEM; ACUITY; RISK; END;
D O I
10.1016/j.jcrs.2015.03.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the feasibility of a new injectable telescopic intraocular lens (IOL). SETTING: London Eye Hospital, London, United Kingdom. DESIGN: Prospective interventional pilot study. METHOD: Eyes with bilateral, intermediate, or advanced dry age-related macular degeneration (AMD); preoperative decimal corrected distance visual acuity (CDVA) of 0.25 or less; and improvement with extraocular simulation of the intervention had implantation of 2 IOLs designed for use together in a Galilean telescope configuration (iolAMD). Patients were followed for 4 months. Safety was assessed by monitoring visual acuity, intraocular pressure, specular microscopy, and anterior segment and macular optical coherence tomographies. Fixation stability and macular sensitivity were determined using microperimetry in some eyes. RESULTS: There were no significant intraoperative or postoperative complications. In 1 eye, an anterior sulcus IOL was replaced; there were no sequelae. The mean endothelial cell density was reduced by 18%. The mean decimal CDVA improved from 0.12 preoperatively to 0.20 at 4 months, a 67% gain. The mean change in spherical equivalent after implantation was -1.5 diopters (D) with 0.5 D of induced astigmatism. Microperimetric testing indicated a magnification effect and a deviation of the retinal image by up to 5 degrees, with improved fixation stability. CONCLUSIONS: This injectable intraocular miniature telescope appears safe in the short to medium term and capable of improving visual function. No significant issues were encountered regarding candidate eye selection or patient retention and cooperation. Further work is needed to evaluate the safety and efficacy of the device, particularly with respect to daily-living activities and the range of indications. (C) 2015 ASCRS and ESCRS
引用
收藏
页码:2125 / 2135
页数:11
相关论文
共 50 条
  • [41] Systemic lidocaine infusion as an analgesic for intraocular surgery in dogs: a pilot study
    Smith, LJ
    Bentley, E
    Shih, A
    Miller, PE
    VETERINARY ANAESTHESIA AND ANALGESIA, 2004, 31 (01) : 53 - 63
  • [42] Pilot study of new focus-shift accommodating intraocular lens
    Cleary, Georgia
    Spalton, David J.
    Marshall, John
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05): : 762 - 770
  • [43] Pilot study of two new injectable bulking agents for the treatment of faecal incontinence
    Maeda, Y.
    Vaizey, C. J.
    Kamm, M. A.
    COLORECTAL DISEASE, 2008, 10 (03) : 268 - 272
  • [44] A pilot study of intraocular lens explantation in 69 eyes in Chinese patients
    Fang Chai
    Bo Ma
    Xin-Guang Yang
    Juan Li
    Mei-Fang Chu
    International Journal of Ophthalmology, 2017, (04) : 579 - 585
  • [45] Pilot study of two new injectable bulking agents for the treatment of faecal incontinence
    Maeda, Yasuko
    Vaizey, Carolynne J.
    Kamm, Michael A.
    GASTROENTEROLOGY, 2007, 132 (04) : A683 - A683
  • [46] Magnification of the retinal image through an intraocular Galilean telescope
    Felipe, A.
    Artigas, J. M.
    Gomez-Chova, J.
    Garcia-Delpech, S.
    Diaz-Llopis, M.
    JOURNAL OF MODERN OPTICS, 2010, 57 (02) : 152 - 158
  • [47] Optical-Quality Assessment of a Miniaturized Intraocular Telescope
    Nepita, Irene
    Raimondi, Raffaele
    Piazza, Simonluca
    Diaspro, Alberto
    Vidal-Aroca, Faustino
    Surdo, Salvatore
    Romano, Mario R.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (10)
  • [48] The implantable intraocular telescope - a technology missing its purpose?
    Markowitz, SN
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2005, 40 (05): : 541 - 542
  • [49] PILOT-LIKE TELESCOPE POTENTIAL
    Storey, J. W. V.
    Ashley, M. C. B.
    Burton, M. G.
    Lawrence, J. S.
    Saunders, W.
    2nd Arena Conference on The Astrophysical Science Cases at Dome C, 2008, 33 : 207 - 211
  • [50] Functionalised polysiloxanes as injectable, in situ curable accommodating intraocular lenses
    Hao, Xiaojuan
    Jeffery, Justine L.
    Wilkie, John S.
    Meijs, Gordon F.
    Clayton, Anthony B.
    Watling, Jason D.
    Ho, Arthur
    Fernandez, Viviana
    Acosta, Carolina
    Yamamoto, Hideo
    Aly, Mohamed G. M.
    Parel, Jean-Marie
    Hughes, Timothy C.
    BIOMATERIALS, 2010, 31 (32) : 8153 - 8163