Injectable intraocular telescope: Pilot study

被引:19
|
作者
Qureshi, Muhammad A. [1 ,2 ]
Robbie, Scott J. [2 ]
Tabernero, Juan [3 ]
Artal, Pablo
机构
[1] London Eye Hosp, London W1G 9PB, England
[2] London Eye Hosp Pharma, London, England
[3] Univ Murcia, Lab Opt, Murcia, Spain
来源
关键词
MACULAR DEGENERATION; SURGERY; DISEASE; SYSTEM; ACUITY; RISK; END;
D O I
10.1016/j.jcrs.2015.03.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the feasibility of a new injectable telescopic intraocular lens (IOL). SETTING: London Eye Hospital, London, United Kingdom. DESIGN: Prospective interventional pilot study. METHOD: Eyes with bilateral, intermediate, or advanced dry age-related macular degeneration (AMD); preoperative decimal corrected distance visual acuity (CDVA) of 0.25 or less; and improvement with extraocular simulation of the intervention had implantation of 2 IOLs designed for use together in a Galilean telescope configuration (iolAMD). Patients were followed for 4 months. Safety was assessed by monitoring visual acuity, intraocular pressure, specular microscopy, and anterior segment and macular optical coherence tomographies. Fixation stability and macular sensitivity were determined using microperimetry in some eyes. RESULTS: There were no significant intraoperative or postoperative complications. In 1 eye, an anterior sulcus IOL was replaced; there were no sequelae. The mean endothelial cell density was reduced by 18%. The mean decimal CDVA improved from 0.12 preoperatively to 0.20 at 4 months, a 67% gain. The mean change in spherical equivalent after implantation was -1.5 diopters (D) with 0.5 D of induced astigmatism. Microperimetric testing indicated a magnification effect and a deviation of the retinal image by up to 5 degrees, with improved fixation stability. CONCLUSIONS: This injectable intraocular miniature telescope appears safe in the short to medium term and capable of improving visual function. No significant issues were encountered regarding candidate eye selection or patient retention and cooperation. Further work is needed to evaluate the safety and efficacy of the device, particularly with respect to daily-living activities and the range of indications. (C) 2015 ASCRS and ESCRS
引用
收藏
页码:2125 / 2135
页数:11
相关论文
共 50 条
  • [31] A pilot study of intraocular lens explantation in 69 eyes in Chinese patients
    Chai, Fang
    Ma, Bo
    Yang, Xin-Guang
    Li, Juan
    Chu, Mei-Fang
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (04) : 579 - 585
  • [32] A pilot study of the precision of digital intraocular pressure measurement during vitrectomy
    Can-Can Xue
    Shu-Shan Li
    Jin-Hong Miao
    Se-Fei Wu
    Xue-Ling Tian
    Chun Zhang
    International Journal of Ophthalmology, 2020, (10) : 1574 - 1579
  • [33] A pilot study on endoscopic delivery of injectable bioadhesive for esophageal repair in a porcine model
    Xia, Jie
    Wang, Wenxin
    Guo, Jinghui
    Wu, Jinglei
    Wan, Xinjian
    BIOMEDICAL MATERIALS, 2024, 19 (05)
  • [34] Digital training for self-injectable contraceptives: a feasibility and acceptability pilot study
    Mills, Rhiana
    Krong, Rapha
    Kithinji, Fiona
    Baraitser, Paula
    BMJ SEXUAL & REPRODUCTIVE HEALTH, 2024,
  • [35] A pilot study of vasculogenic mimicry immunohistochemical expression in intraocular melanoma model
    Chen, Luxia
    Zhang, Shiwu
    Li, Xiaorong
    Sun, Baocun
    Zhao, Xiulan
    Zhang, Danfang
    Zhao, Shaozhen
    ONCOLOGY REPORTS, 2009, 21 (04) : 989 - 994
  • [36] Clinical outcomes with a new design in multifocal intraocular lens: a pilot study
    Jorge L. Alió
    Pilar Yébana
    Mario Cantó
    Ana B. Plaza
    Alfredo Vega
    Jorge L. Alió del Barrio
    Francisco Lugo
    Eye and Vision, 7
  • [37] Clinical outcomes with a new design in multifocal intraocular lens: a pilot study
    Alio, Jorge L.
    Yebana, Pilar
    Canto, Mario
    Plaza, Ana B.
    Vega, Alfredo
    Alio del Barrio, Jorge L.
    Lugo, Francisco
    EYE AND VISION, 2020, 7 (01)
  • [38] EFFECT OF METOPROLOL ON INTRAOCULAR-PRESSURE IN GLAUCOMA - PILOT-STUDY
    ALM, A
    WICKSTROM, CP
    EKSTROM, C
    OHMAN, L
    ACTA OPHTHALMOLOGICA, 1979, 57 (02): : 236 - 242
  • [39] Assessment of changes in corneal shape as a function of intraocular pressure: A pilot study
    Brenman, K
    Tahi, H
    Manns, F
    Duchesne, B
    Parel, JM
    Lacombe, E
    OPHTHALMIC TECHNOLOGIES X, 2000, 3908 : 108 - 114
  • [40] A pilot study of the precision of digital intraocular pressure measurement during vitrectomy
    Xue, Can-Can
    Li, Shu-Shan
    Miao, Jin-Hong
    Wu, Se-Fei
    Tian, Xue-Ling
    Zhang, Chun
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (10) : 1574 - 1579