Ultrasound fusion image error correction using subject-specific liver motion model and automatic image registration

被引:7
|
作者
Yang, Minglei [1 ,3 ]
Ding, Hui [1 ,3 ]
Zhu, Lei [2 ,4 ]
Wang, Guangzhi [1 ,3 ]
机构
[1] Tsinghua Univ, Sch Med, Dept Biomed Engn, Beijing 100084, Peoples R China
[2] Beijing Shen Mindray Med Elect Technol Res Inst C, Beijing 100085, Peoples R China
[3] Tsinghua Univ, Sch Med, Room C249, Beijing 100084, Peoples R China
[4] 3F Bldg5,8 Chuangye Rd, Beijing 100085, Peoples R China
基金
中国国家自然科学基金;
关键词
Ultrasound fusion imaging; Respiration-induced fusion error; Subject-specific motion model; Automatic image registration; Liver;
D O I
10.1016/j.compbiomed.2016.10.008
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: Ultrasound fusion imaging is an emerging tool and benefits a variety of clinical applications, such as image-guided diagnosis and treatment of hepatocellular carcinoma and unresectable liver metastases. However, respiratory liver motion-induced misalignment of multimodal images (i.e., fusion error) compromises the effectiveness and practicability of this method. The purpose of this paper is to develop a subject-specific liver motion model and automatic registration-based method to correct the fusion error. Methods: An online-built subject-specific motion model and automatic image registration method for 2D ultrasound-3D magnetic resonance (MR) images were combined to compensate for the respiratory liver motion. The key steps included: 1) Build a subject-specific liver motion model for current subject online and perform the initial registration of pre-acquired 3D MR and intra-operative ultrasound images; 2) During fusion imaging, compensate for liver motion first using the motion model, and then using an automatic registration method to further correct the respiratory fusion error. Evaluation experiments were conducted on liver phantom and five subjects. Results: In the phantom study, the fusion error (superior-inferior axis) was reduced from 13.90 +/- 2.38 mm to 4.26 +/- 0.78 mm by using the motion model only. The fusion error further decreased to 0.63 +/- 0.53 mm by using the registration method. The registration method also decreased the rotation error from 7.06 +/- 0.21 degrees to 1.18 +/- 0.66. In the clinical study, the fusion error was reduced from 12.90 +/- 9.58 nun to 6.12 +/- 2.90 mm by using the motion model alone. Moreover, the fusion error decreased to 1.96 +/- 0.33 mm by using the registration method. Conclusions: The proposed method can effectively correct the respiration-induced fusion error to improve the fusion image quality. This method can also reduce the error correction dependency on the initial registration of ultrasound and MR images. Overall, the proposed method can improve the clinical practicability of ultrasound fusion imaging.
引用
收藏
页码:99 / 109
页数:11
相关论文
共 50 条
  • [41] Correction of Parameter Error in Rotating Linear Probe Using Image Registration for Ultrasonic Diagnostic Imaging
    Choi, Myoung Hwan
    2008 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS, VOLS 1-4, 2008, : 807 - 810
  • [42] A review of the image segmentation and registration methods in liver motion correction in C-arm perfusion imaging
    Haseljic, Hana
    Frysch, Robert
    Kulvait, Vojtech
    Rose, Georg
    2019 XXVII INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATION AND AUTOMATION TECHNOLOGIES (ICAT 2019), 2019,
  • [43] 4D Ultrasound Calibration for Radiotherapy Guidance Using Automatic Intramodality Image Registration
    Schlosser, J.
    Kirmizibayrak, C.
    Shamdasani, V.
    Metz, S.
    Hristov, D.
    MEDICAL PHYSICS, 2012, 39 (06) : 3617 - 3617
  • [44] Automatic Mitral Annulus Tracking In Volumetric Ultrasound Using Non-rigid Image Registration
    De Veene, Henri
    Bertrand, Philippe B.
    Popovic, Natasa
    Vandervoort, Pieter M.
    Claus, Piet
    De Beule, Matthieu
    Heyde, Brecht
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 1985 - 1988
  • [45] Motion effect reduction using high performance combined registration in PET/CT image fusion
    Chen, Shuguang
    Ma, Jieyan
    Li, Weijuan
    Li, Chenwei
    Chen, Mu
    Shi, Hongcheng
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [46] Motion Correction in Dual Gated Cardiac PET Using Mass-Preserving Image Registration
    Gigengack, Fabian
    Ruthotto, Lars
    Burger, Martin
    Wolters, Carsten H.
    Jiang, Xiaoyi
    Schaefers, Klaus P.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (03) : 698 - 712
  • [47] Respiratory motion correction of liver contrast-enhanced ultrasound sequences by selecting reference image automatically
    Zhang Ji
    Zhang Yan-Rong
    Chen Juan
    Chen Xiao-Hui
    Zhong Xiao-Li
    MEDICAL IMAGING 2017: ULTRASONIC IMAGING AND TOMOGRAPHY, 2017, 10139
  • [48] GENERATION OF 12-LEAD ELECTROCARDIOGRAM WITH SUBJECT-SPECIFIC, IMAGE-DERIVED CHARACTERISTICS USING A CONDITIONAL VARIATIONAL AUTOENCODER
    Sang, Yuling
    Beetz, Marcel
    Grau, Vicente
    2022 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (IEEE ISBI 2022), 2022,
  • [49] Three-dimensional reconstruction of extremity tumor regions by CT and MRI image data fusion for subject-specific preoperative assessment and planning
    Dong, Yuefu
    Dong, Yinghai
    Hu, Guanghong
    Xu, Qingrong
    COMPUTER AIDED SURGERY, 2011, 16 (05) : 220 - 233
  • [50] 3D Ultrasound to 3D MR Image Registration for Motion Management in the Liver Using Novel MR-Compatible Ultrasound Probe
    Jupitz, S.
    Bednarz, B.
    MEDICAL PHYSICS, 2022, 49 (06) : E506 - E506