Adaptive Digital X-Ray Detector for High Sensitivity Medical Fluoroscopy Imaging

被引:0
|
作者
Smith, Joseph T. [1 ]
Forsythe, Eric W. [2 ]
Allee, David R. [3 ]
Christen, Jennifer Blain [3 ]
机构
[1] ASU Flexible Elect & Display Ctr, Tempe, AZ 85284 USA
[2] US Army Res Lab, Adelphi, MD 20783 USA
[3] Arizona State Univ, Tempe, AZ 85281 USA
关键词
X-ray imaging; fluoroscopy; thin-film transistor; TFT; active matrix array; LEAKAGE CURRENTS; CHARGE EMISSION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This work presents a new approach to increase the sensitivity of digital x-ray detectors used for medical fluoroscopy imaging by increasing the signal-to-noise ratio (SNR) of the detected x-ray image signal. The improvement is achieved by recognizing that in some medical imaging scenarios, the object or region of interest that needs to be x-rayed may only cover a fraction of the entire digital x-ray detector imaging array. Our new approach is designed to improve imaging sensitivity by re-configuring the detector array to capture and display only the small localized portion of the array that the health care provider would like imaged, while simultaneously disabling the unused portion of the imaging array. Using transient TFT leakage current measurements, we show how the detector noise level can be lowered as a function of the number of rows disabled.
引用
收藏
页码:604 / 607
页数:4
相关论文
共 50 条
  • [21] White beam synchrotron topography using a high resolution digital X-ray imaging detector
    Danilewsky, A. N.
    Rack, A.
    Wittge, J.
    Weitkamp, T.
    Simon, R.
    Riesemeier, H.
    Baumbach, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (09): : 2035 - 2040
  • [22] Characterization of digital systems used in medical X-ray imaging
    Perez, A. M. M. M.
    Poletti, M. E.
    RADIATION PHYSICS AND CHEMISTRY, 2022, 200
  • [23] Optimization of detector pixel size for interventional x-ray fluoroscopy
    Manjeshwar, RM
    Wilson, DL
    MEDICAL IMAGING 2001: IMAGE PERCEPTION AND PERFORMANCE, 2001, 4324 : 23 - 34
  • [24] Digital image acquisition and processing in medical x-ray imaging
    Aach, T
    Schiebel, U
    Spekowius, G
    JOURNAL OF ELECTRONIC IMAGING, 1999, 8 (01) : 7 - 22
  • [25] Digital X-Ray Imaging
    Dance, David R.
    MOLECULAR IMAGING: COMPUTER RECONSTRUCTION AND PRACTICE, 2008, : 9 - 18
  • [26] A direct X-ray digital radiology system for use in mammography, dental imaging, fluoroscopy and conventional X-ray examinations.
    Spartiotis, K
    Orava, R
    Schulman, T
    Pyyhtia, J
    Cao, TL
    Sarakinos, M
    Suni, I
    Salonen, J
    Gronberg, L
    Majander, P
    Karim, Z
    Allison, D
    Sanghera, B
    Myers, M
    Epenetos, A
    CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1997, 1134 : 17 - 23
  • [27] Detector Development for X-ray Imaging
    Mentzer, M. A.
    Herr, D. A.
    Brewer, K. J.
    Ojason, N.
    Tarpine, H. A.
    OPTICAL COMPONENTS AND MATERIALS VII, 2010, 7598
  • [28] Projection X-ray Imaging: Radiography, Mammography, Fluoroscopy
    Seibert, James Anthony
    HEALTH PHYSICS, 2019, 116 (02): : 148 - 156
  • [29] Progress in electron-multiplying CCD (EMCCD) based, highresolution, high-sensitivity x-ray detector for fluoroscopy and radiography
    Kuhls, Andrew T.
    Yadava, Girijesh
    Patel, Vikas
    Bednarek, Daniel R.
    Rudin, Stephen
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [30] Stent Enhancement Using a Locally Adaptive Unsharp Masking Filter in Digital X-ray Fluoroscopy
    Jiang, Yuhao
    Ekanayakea, Eranda
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034