Projection X-ray Imaging: Radiography, Mammography, Fluoroscopy

被引:5
|
作者
Seibert, James Anthony [1 ]
机构
[1] Univ Calif Davis Hlth, Dept Radiol, 4860 Y St,Suite 3100, Sacramento, CA 95817 USA
来源
HEALTH PHYSICS | 2019年 / 116卷 / 02期
关键词
National Council on Radiation Protection and Measurements; fluoroscopy; radiation dose; x rays; PERFORMANCE;
D O I
10.1097/HP.0000000000001028
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Recent advances in digital detector technology for medical radiography and fluoroscopy have resulted in improved workflow efficiency, operational flexibility, image quality, and diagnostic accuracy. This is attributed to the implementation of portable flat-panel x-ray detector devices able to provide real-time readout, processing, and display of medical images. As a result, digital radiography flat-panel detectors are rapidly replacing computed radiography passive detectors for projection imaging exams and image intensifier detectors for dynamic fluoroscopy exams. Advanced exam capabilities now include digital tomosynthesis and dual-energy radiography; the former is based on rapid acquisition of multiple angle-dependent image projections to synthesize tomographic slabs at selectable depths within the patient, and the latter is based on rapid back-to-back acquisition of the same anatomy at low and high x-ray energies to generate separate soft tissue and bone images. In both situations, superimposition of anatomy is reduced or eliminated, with the possibility of enhanced diagnostic confidence. Increased x-ray absorption efficiency and lower electronic noise of digital radiography detectors compared to computed radiography detectors enable equal image quality at lower patient dose; however, because of a disconnect between image appearance and radiation dose, lower patient dose is not always achieved. Education, training, and implementation of standards such as the International Electrotechnical Commission 62494-1 Digital Radiography Exposure Index are needed to ensure image quality at the lowest appropriate radiation dose. The National Council on Radiation Protection and Measurements can contribute to radiation responsibility in medical imaging by providing guidance on use of digital radiography, including recommendations for acquisition protocols and exposure index standards, for development of radiographic exam diagnostic reference levels, and for oversight of retake and reject analysis.
引用
收藏
页码:148 / 156
页数:9
相关论文
共 50 条
  • [1] X-ray scatter in projection radiography
    Ylimaula, Satu
    Rasanen, Lasse
    Hurskainen, Miia
    Peuna, Arttu
    Julkunen, Petro
    Nieminen, Miika Tapio
    Hanni, Matti
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (02) : 120 - 129
  • [2] X-RAY-IMAGING - PROJECTION RADIOGRAPHY
    TANG, CM
    KUNDEL, HL
    RAVIN, CE
    HUANG, HK
    DESLATTES, RD
    BOYD, DP
    GUR, D
    ACADEMIC RADIOLOGY, 1995, 2 : S111 - S112
  • [3] X-ray tubes for projection X-ray radiography of new generation
    Podimsky, A. A.
    Potrakhov, N. N.
    3RD INTERNATIONAL CONFERENCE ON X-RAY TECHNIQUE, 2017, 808
  • [4] X-ray projection imaging
    Seibert, JA
    IMAGING IN RADIATION THERAPY, 1998, (24): : 103 - 134
  • [5] A direct X-ray digital radiology system for use in mammography, dental imaging, fluoroscopy and conventional X-ray examinations.
    Spartiotis, K
    Orava, R
    Schulman, T
    Pyyhtia, J
    Cao, TL
    Sarakinos, M
    Suni, I
    Salonen, J
    Gronberg, L
    Majander, P
    Karim, Z
    Allison, D
    Sanghera, B
    Myers, M
    Epenetos, A
    CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1997, 1134 : 17 - 23
  • [6] Point projection radiography with the flexible x-ray integer
    Budil, KS
    Perry, TS
    Alvarez, SA
    Hargrove, D
    Mazuch, JR
    Nikitin, A
    Bell, PM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01): : 796 - 798
  • [7] Three dimensional modeling of projection x-ray radiography
    Gray, Joseph N.
    Review of Progress in Quantitative Nondestructive Evaluation, 1988, 7 A : 343 - 348
  • [8] Point projection radiography with the flexible x-ray imager
    Budil, K.S.
    Perry, T.S.
    Alvarez, S.A.
    Hargrove, D.
    Mazuch, J.R.
    Nikitin, A.
    Bell, P.M.
    Review of Scientific Instruments, 1997, 68 (1 pt 2):
  • [9] X-ray induced pinhole closure in point-projection x-ray radiography
    Bullock, A. B.
    Landen, O. L.
    Blue, B. E.
    Edwards, J.
    Bradley, D. K.
    JOURNAL OF APPLIED PHYSICS, 2006, 100 (04)
  • [10] Elimination of gridlines in X-ray imaging for mammography
    Maruyama, Toshinori
    Yamamoto, Hideki
    IST 2006: PROCEEDINGS OF THE 2006 IEEE INTERNATIONAL WORKSHOP ON IMAGING SYSTEMS AND TECHNIQUES, 2006, : 103 - +