Saturated pool boiling from carbon nanotube coated surfaces at different orientations

被引:50
|
作者
Ho, J. Y. [1 ]
Leong, K. C. [1 ]
Yang, C. [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
关键词
Saturated pool boiling; Surface orientation; Carbon nanotube; Bare silicon; Critical heat flux; CRITICAL HEAT-FLUX; MICRO-PIN-FINS; ENHANCED SURFACES; SILICON CHIPS; NUCLEATE; GRAPHITE; HFE-7100; FC-72; SIZE; CHF;
D O I
10.1016/j.ijheatmasstransfer.2014.08.053
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experiments were conducted to investigate the effects of carbon nanotube (CNT) coated surfaces and the influence of surface orientations on saturated pool boiling heat transfer and critical heat flux (CHF). A 1 cm x 1 cm fully coated CNT surface and an interlaced patterned CNT surface of coating thickness 215 mu m were prepared. In FC-72 under atmospheric condition, bare silicon, fully coated CNT surface and interlaced patterned CNT surface were initially tested at constant surface orientation of 90 degrees to determine the effect of CNT coating. Further experiments were then carried out with bare silicon and fully coated CNT surface at 0 degrees, 30 degrees, 60 degrees, 120 degrees, 150 degrees and 180 degrees to examine and compare the effects of surface orientation. Results showed that at constant surface orientation of 90, both the fully coated CNT surface and the interlaced patterned CNT surface enhanced the average heat transfer coefficient by 42% as compared to the bare silicon despite the interlaced patterned CNT surface having only 70% CNT coating area. On the influence of surface orientation, results with the fully coated CNT surface showed that heat transfer performance decreases with increasing surface orientation whereas bare silicon exhibited improvement in heat transfer between 0 degrees and 90 degrees and deterioration in heat transfer between 90 degrees and 180 degrees. In addition, CNT coatings were also found to enhance CHF as the CHF of fully coated CNT surface consistently surpassed those of bare silicon for the same orientation. On the other hand, a similar trend on the dependence of CHF on orientation was observed, where CHF of bare silicon and fully coated CNT surface were seen to decrease with increasing surface orientation. The highest average heat transfer coefficient of 0.45 W/cm(2) K and highest CHF of 20.1 W/cm(2) were recorded for fully coated CNT surface at 0 degrees surface orientation. Lastly, for both bare silicon and fully coated CNT surface, Rohsenow's correlation was used to characterize the pool boiling curves and the models of Kutateladze and Zuber were used to develop the CHF correlations at different surface orientations. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:893 / 904
页数:12
相关论文
共 50 条
  • [41] Critical Heat Flux and Near-Wall Boiling Behaviors in Saturated and Subcooled Pool Boiling on Vertical and Inclined Surfaces
    Sakashita, Hiroto
    Ono, Ayako
    Nyui, Junji
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2009, 46 (11) : 1038 - 1048
  • [42] Pool boiling inversion and secondary boiling effect on CNTs-Cu nanoparticles-coated porous surfaces
    Kim, Jin Soo
    Park, Si Ho
    Kang, Sung-Soo
    Kim, Hong Gun
    Kwac, Lee Ku
    Hong, Sung Joo
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2024, 38 (06) : 3177 - 3184
  • [43] Saturation and Subcooled Boiling of HFE-7100 on Pinned Surfaces at Different Orientations
    Parker, Jack L.
    El-Genk, Mohamed S.
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2009, 23 (02) : 381 - 391
  • [44] Critical heat flux of pool boiling on Si nanowire array-coated surfaces
    Lu, Ming-Chang
    Chen, Renkun
    Srinivasan, Vinod
    Carey, Van P.
    Majumdar, Arun
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (25-26) : 5359 - 5367
  • [45] Experimental studies on CHF of pool boiling on horizontal conductive micro porous coated surfaces
    Li, Chen
    Peterson, G. P.
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM STAIF 2008, 2008, 969 : 12 - 20
  • [46] Pool boiling of iso-butane and quasi azeotropic refrigerant mixture on coated surfaces
    Dewangan, Ashok K.
    Kumar, Anil
    Kumar, Ravi
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 85 : 176 - 188
  • [47] Critical heat flux for downward-facing saturated pool boiling on pin fin surfaces
    Zhong, Dawen
    Meng, Ji'an
    Li, Zhixin
    Guo, Zengyuan
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 87 : 201 - 211
  • [48] An analytical model for near-saturated pool boiling critical heat flux on vertical surfaces
    Mudawar, I
    Howard, AH
    Gersey, CO
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (10) : 2327 - 2339
  • [49] Void Fraction Measurements During Saturated Pool Boiling of Water on Partially Wetted Vertical Surfaces
    Liaw, S. P.
    Dhir, V. K.
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1989, 111 (1-4): : 731 - 738
  • [50] EFFECTS OF PORE DIAMETERS AND SYSTEM PRESSURE ON SATURATED POOL NUCLEATE BOILING HEAT-TRANSFER FROM POROUS SURFACES
    NAKAYAMA, W