Saturated pool boiling from carbon nanotube coated surfaces at different orientations

被引:50
|
作者
Ho, J. Y. [1 ]
Leong, K. C. [1 ]
Yang, C. [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
关键词
Saturated pool boiling; Surface orientation; Carbon nanotube; Bare silicon; Critical heat flux; CRITICAL HEAT-FLUX; MICRO-PIN-FINS; ENHANCED SURFACES; SILICON CHIPS; NUCLEATE; GRAPHITE; HFE-7100; FC-72; SIZE; CHF;
D O I
10.1016/j.ijheatmasstransfer.2014.08.053
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experiments were conducted to investigate the effects of carbon nanotube (CNT) coated surfaces and the influence of surface orientations on saturated pool boiling heat transfer and critical heat flux (CHF). A 1 cm x 1 cm fully coated CNT surface and an interlaced patterned CNT surface of coating thickness 215 mu m were prepared. In FC-72 under atmospheric condition, bare silicon, fully coated CNT surface and interlaced patterned CNT surface were initially tested at constant surface orientation of 90 degrees to determine the effect of CNT coating. Further experiments were then carried out with bare silicon and fully coated CNT surface at 0 degrees, 30 degrees, 60 degrees, 120 degrees, 150 degrees and 180 degrees to examine and compare the effects of surface orientation. Results showed that at constant surface orientation of 90, both the fully coated CNT surface and the interlaced patterned CNT surface enhanced the average heat transfer coefficient by 42% as compared to the bare silicon despite the interlaced patterned CNT surface having only 70% CNT coating area. On the influence of surface orientation, results with the fully coated CNT surface showed that heat transfer performance decreases with increasing surface orientation whereas bare silicon exhibited improvement in heat transfer between 0 degrees and 90 degrees and deterioration in heat transfer between 90 degrees and 180 degrees. In addition, CNT coatings were also found to enhance CHF as the CHF of fully coated CNT surface consistently surpassed those of bare silicon for the same orientation. On the other hand, a similar trend on the dependence of CHF on orientation was observed, where CHF of bare silicon and fully coated CNT surface were seen to decrease with increasing surface orientation. The highest average heat transfer coefficient of 0.45 W/cm(2) K and highest CHF of 20.1 W/cm(2) were recorded for fully coated CNT surface at 0 degrees surface orientation. Lastly, for both bare silicon and fully coated CNT surface, Rohsenow's correlation was used to characterize the pool boiling curves and the models of Kutateladze and Zuber were used to develop the CHF correlations at different surface orientations. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:893 / 904
页数:12
相关论文
共 50 条
  • [21] Performance of different structured surfaces in nucleate pool boiling
    Das, A. K.
    Das, P. K.
    Saha, P.
    APPLIED THERMAL ENGINEERING, 2009, 29 (17-18) : 3643 - 3653
  • [22] Pool boiling experiments on multiwalled carbon nanotube (MWCNT) forests
    Ahn, Hee Seok
    Sinha, Nipun
    Zhang, Mei
    Banerjee, Debjyoti
    Fang, Shaoli
    Baughman, Ray H.
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2006, 128 (12): : 1335 - 1342
  • [23] Effect of Subcooling on Pool Boiling of Water from Sintered Copper Microporous Coating at Different Orientations
    Jun, Seongchul
    Kim, Jinsub
    You, Seung M.
    Kim, Hwan Yeol
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2018, 2018
  • [24] An analysis of pool boiling heat transfer on nanoparticle-coated surfaces
    Cao, Zhen
    Wu, Zan
    Abbood, Sahar
    Sunden, Bengt
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 5880 - 5887
  • [25] Effects of heater size and orientation on pool boiling heat transfer from microporous coated surfaces
    Rainey, KN
    You, SM
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (14) : 2589 - 2599
  • [26] Saturated pool boiling of FC-72 from enhanced surfaces produced by Selective Laser Melting
    Ho, J. Y.
    Wong, K. K.
    Leong, K. C.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 99 : 107 - 121
  • [27] Enhanced pool boiling using carbon nanotube arrays on a silicon surface
    Ujereh, Sebastine O., Jr.
    Mudawar, Issam
    Amama, Placidus B.
    Fisher, Timothy S.
    Qu, Weilin
    PROCEEDINGS OF THE ASME HEAT TRANSFER DIVISION 2005, VOL 1, 2005, 376-1 : 691 - 696
  • [28] Pool Boiling of NOVEC-649 on Microparticle-Coated and Nanoparticle-Coated Surfaces
    Cao, Zhen
    Wu, Zan
    Sunden, Bengt
    HEAT TRANSFER ENGINEERING, 2021, 42 (19-20) : 1732 - 1747
  • [29] BOILING VISUALIZATION AND CRITICAL HEAT FLUX (CHF) PHENOMENA ON PCB IN A SATURATED POOL AT VARIOUS SURFACE ORIENTATIONS
    Tanjung, Elvira F.
    Jo, Daeseong
    PROCEEDINGS OF THE 26TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2018, VOL 9, 2018,
  • [30] Parametric study of pool boiling on horizontal highly conductive microporous coated surfaces
    Li, Chen
    Peterson, G. P.
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2007, 129 (11): : 1465 - 1475